In-situ Raman Electrochemical Cell Assembly

Captions


  1. Start by assembling the Working Electrode. 
  2. Insert the Working Electrode Holder with an O-ring
  3. Loosen the screw and carefully attach the Working Electrode (WE).  
  4. You can attach a WE of your choice. Normal, SERS, SHINERS 
  5. Rotate the WE to position it closer to the Window. Make sure active material is coated on this side 
  6. Secure the Electrode properly 
  7. Specially designed Detachable L-shaped Glassy Carbon will also fit into the cell  
  8. Need to Purchase Separately (C2040A1)  
  9. L-shape design helps to reduce distortions by reducing the Gap between the WE and the Window 
  10. Electrode Holder vs L Shaped Electrode Holder
    Electrode Holder vs L Shaped Electrode Holder
  11. You can attach the Reference and Counter Electrodes next
  12. Adjust the O-ring to make the Reference Electrode positions well 
  13. Use similar technique to position the Counter Electrode well 
  14. Let’s attach the gas line now 
  15. Use 3 mm inner diameter gas feedthrough screws to secure the line  
  16. Recommended to use the lower port as the Gas Inlet  
  17. Upper one as the Gas Outlet 
  18. Push-fit connectors are provided to extend the gas tubing towards Swagelok fittings or Gas Analysis Chambers 
  19. Let’s fit the Optical Window now  - Gaskets with different thickness are provided allowing users to adjust the distance between the electrode and the Optical Window
  20. Remove the PTFE Cap. Use the tool provided if too tight 
  21. Place the gasket (Peel off the cover when you do it) 
  22. You can fill up the electrolyte now before fitting the Optical window  
  23. Place the Optical Window now. Quartz provided with the package 
  24. Tighten the Lid 
  25. Now you are ready to start your experiment 
  26. Additional port is provided on the side. You can use it for sampling, temperature probing, gas purging, etc 
  27. Contact Us through the product page or support@ossila.com for further support

What's Included


Included with In-Situ Raman Cell
Items included with In-Situ Raman Cell (C2035R1)

The standard items included with the C2035R1 In-situ Raman Electrochemical Cell in the assembly video above are the following

  • 1 x PTFE cell
  • 1 x PEEK platinum sheet electrode holder
  • 1 x φ0.5*37mm platinum wire electrode
  • 1 x φ6mm silver chloride reference electrode
  • 1 x suction cup
  • 1 x Nylon hand screw accessories
  • 1 x PTFE tube φ3mm
  • 2 x φ3mm PU quick connect
  • 5 x φ41*1mm quartz light window
  • 8 x light window sealing fluorine rubber gasket
  • 6 x electrode hole sealing screw
  • 4 x gas hole sealing screw

Spectroelectrochemical Cells Collection

Spectro-electrochemical Cells

Spectroelectrochemical Cells

Explore our Spectroelectrochemical range, including in-situ Raman Cells.

Electrochemical Cell Collection

Electrochemical Cells

Electrochemical Cells

Explore our range of electrochemical cells.

Electrochemical Cell Collection

Electrodes

Electrodes

Explore our range of electrodes, including the glassy carbon working electrode.

Contributing Authors


Written by

Dr. Shadeepa Karunarathne

Product Development Electrochemist

Videography by

Sam Force

Graphic Designer