{"title":"Popular Products","description":"","products":[{"product_id":"uv-ozone-cleaner","title":"UV Ozone Cleaner","description":"\u003ch2 id=\"product-oneliner\"\u003eLow Price System for Ultra-Clean Surfaces in Minutes\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eProduce near-atomically clean surfaces without causing damage to your sample\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eWithin minutes, the Ossila UV Ozone Cleaner is capable of removing contamination from the surface of substrates and samples. Using a high-power UV light source to generate ozone and break down organic surface contaminants, you can produce near-atomically clean surfaces without causing any damage to your sample. Volatile compounds created from surface contaminants will quickly evaporate, leaving the sample ready for the next part of your experiment.\u003c\/p\u003e\n\u003cp\u003eThe cleaning area has a diameter of 153 mm (6\"), providing plenty of space to clean multiple samples at once, microscope slides, or even petri dishes. During cleaning, your delicate samples are protected from overheating as the integrated software monitors the internal temperature and provides readings for the tray, lamp, and electronics.\u003c\/p\u003e\n\u003cp\u003eAn essential addition to any lab, our UV ozone cleaner is able to treat a wide range of materials for a number of different applications.\u003c\/p\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Lightweight Body\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Lightweight.svg?v=1697194928\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eLightweight Body\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eEasily moved\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"High intensity UV lamp\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_UV.svg?v=1697551872\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eHigh Intensity UV Lamp\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eEmission at 185 and 254 nm\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Safe\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Saftey_First.svg?v=1697623721\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eSafe Design\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eIncluding thermal cutoff\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Two-Year Warranty\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Glove_Box_key_Features__Two_year_warranty.svg?v=1718707947\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eTwo-Year Warranty\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eBuy with confidence\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003ch3\u003eLamp Replacement for Fast Cleaning Times\u003c\/h3\u003e\n\u003chr\u003e\n\u003cp\u003eOur UV ozone cleaner is fitted with a high-quality, long-lasting UV bulb, which provides thousands of hours of high intensity light output. However, every UV bulb has a finite lifetime and lower bulb intensity means increased cleaning times. After prolonged use, a new bulb is the best option to speed up your cleaning process—there's no need to purchase a new system.\u003c\/p\u003e\n\u003cp\u003eWhen this happens, you can use our \u003ca href=\"#replacement-service\"\u003eUV Lamp Replacement Service\u003c\/a\u003e. We will replace your bulbs, fully test all components, and safely dispose of your old bulbs. This ensures minimal downtime and maximum lifetime for your equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure\u003e\u003cvideo class=\"widescreen\" controls=\"controls\" controlslist=\"nodownload\" crossorigin=\"\" height=\"477.172\" poster=\"https:\/\/cdn.ossila.com\/videos\/uv-ozone-cleaner-product-overview.jpg\" preload=\"none\" title=\"Product overview video for the Ossila UV Ozone Cleaner\" width=\"848.328\"\u003e\n\u003csource src=\"https:\/\/cdn.ossila.com\/videos\/uv-ozone-cleaner-product-overview-1080p.mp4\" type=\"video\/mp4\"\u003e\n\u003ctrack default=\"\" kind=\"subtitles\" label=\"English\" src=\"https:\/\/cdn.ossila.com\/videos\/uv-ozone-cleaner-product-overview.vtt\" srclang=\"en\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"UV Ozone Cleaner Product Overview\",\n\"description\": \"Ossila UV Ozone Cleaner Product Overview\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/uv-ozone-cleaner-product-overview.jpg\",\n\"uploadDate\": \"2023-11-29\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/uv-ozone-cleaner-product-overview-1080p.mp4\",\n\"duration\": \"PT0M24S\"\n}\n\u003c\/script\u003e\u003c\/figure\u003e\n\u003ch2 id=\"specification\"\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eUV Light\u003c\/h3\u003e\n\u003ch4\u003eLamp\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eLamp Type\u003c\/th\u003e\n\u003ctd\u003eLow pressure mercury discharge lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eLamp Dimensions (L x D)\u003c\/th\u003e\n\u003ctd\u003e150 mm x 15 mm (5.91\" x 0.59\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eNumber of Lamps\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDischarge Peaks\u003c\/th\u003e\n\u003ctd\u003e185 nm and 254 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eLamp Lifetime\u003c\/th\u003e\n\u003ctd\u003eT80 lifetime 2,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eSample Irradiance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSample UV Intensity\u003c\/th\u003e\n\u003ctd\u003e15±1 mW·cm\u003csup\u003e-2\u003c\/sup\u003e at 254 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCleaning Area\u003c\/th\u003e\n\u003ctd\u003e153 mm (6\") diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eExposure Time\u003c\/th\u003e\n\u003ctd\u003e1 second – 60 minute, digitally controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg alt=\"Wireframe diagram of the Ossila UV Ozone Cleaner\" height=\"585.750\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Product_Wireframes_UV_Ozone_Cleaner.svg?v=1709633899\" width=\"636\"\u003e\u003c\/figure\u003e\n\u003ch3\u003eDimensions and Weight\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDimensions (W x D x H)\u003c\/th\u003e\n\u003ctd\u003e210 mm x 310 mm x 228 mm (8.27\" x 12.20\" x 8.98\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eTray Illumination Area\u003c\/th\u003e\n\u003ctd\u003e153 mm (6\") diameter circle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Sample Height\u003c\/th\u003e\n\u003ctd\u003e12 mm (0.47\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e5.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMaterials and Finish\u003c\/h3\u003e\n\u003ch4\u003eCase\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e1.5 mm (0.06\") mild steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eTextured black powder coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDrawer Tray\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e1.5 mm (0.06\") stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFinish\u003c\/th\u003e\n\u003ctd\u003e#4 brushed finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eUser Interface\u003c\/h3\u003e\n\u003ch4\u003eDisplay\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eType\u003c\/th\u003e\n\u003ctd\u003e24 bit color TFT LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e480 x 272 px\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSize\u003c\/th\u003e\n\u003ctd\u003e4.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInterface\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDescription\u003c\/th\u003e\n\u003ctd\u003eTactile buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSafety Features\u003c\/h3\u003e\n\u003ch4\u003eEquipment Safety Features\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDrawer Interlock\u003c\/th\u003e\n\u003ctd\u003eHardware interlock sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eTemperature Regulation\u003c\/th\u003e\n\u003ctd\u003eActive lamp cooling - 53 CFM axial fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eThermal Cutoff\u003c\/th\u003e\n\u003ctd\u003eOnboard temperature sensors for software cutoff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePower Supply\u003c\/h3\u003e\n\u003ch4\u003eInput\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eIEC C13 power cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eVoltage Range\u003c\/th\u003e\n\u003ctd\u003e110 V – 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFuse\u003c\/th\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCertification and Standards\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eConformité Européenne (CE) Mark\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eLow Voltage Directive (2014\/35\/EU)\u003c\/p\u003e\n\u003cp\u003eElectromagnetic Compatibility (EMC) (2014\/30\/EU)\u003c\/p\u003e\n\u003cp\u003eRestriction of Hazardous Substances (RoHS) (2011\/65\/EU + 2015\/863)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eBritish Standards Institution (BSI)\u003c\/th\u003e\n\u003ctd\u003eBS EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use. General requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDocumentation\u003c\/h3\u003e\n\u003cp class=\"pad-top-half-height\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/UV-Ozone-Lamp-Spectra.jpg?1276\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"UV Lamp Spectrum\" height=\"20\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px; height: 22px;\" width=\"20\"\u003eUV Lamp Spectrum (graph of relative intensity of emission spectrum)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pad-top-half-height\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/Lamp-Lifetime.svg\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"UV Lamp Lifetime\" height=\"20\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px; height: 22px;\" width=\"20\"\u003eUV Lamp Lifetime (graph of relative intensity over operational time in hours)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pad-top-half-height\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/EU_Declaration_of_Conformity.pdf?v=1722248465\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Declaration of Conformance\" height=\"20\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px; height: 22px;\" width=\"20\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/EU_Declaration_of_Conformity.pdf\"\u003eDeclaration of Conformance (Low Voltage Directive, EMC Directive, RoHS Directive, and BS EN 61010-1:2010)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pad-top-half-height\"\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/manuals\/uv-ozone-cleaner.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg alt=\"Uv Ozone Cleaner manual\" height=\"20\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px; height: 22px;\" width=\"20\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/manuals\/uv-ozone-cleaner.pdf\"\u003eUV Ozone Cleaner Manual (December 2022 onwards)\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv class=\"well alert-warning\"\u003ePlease note that the Ossila UV Ozone Cleaner does \u003cstrong\u003eNOT\u003c\/strong\u003e have an integrated ozone filtration system, and must therefore be operated in a working fume hood.\u003c\/div\u003e\n\u003ch2 id=\"features\"\u003eUV Ozone Cleaner Features\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"UV Ozone Mercury Vapour Discharge Lamp\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/uv-ozone-cleaner-lamp-square.jpg?v=1670229166\u0026amp;width=190\u0026amp;height=190\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eHigh Intensity UV Lamp\u003c\/p\u003e\n\u003cp\u003eHousing a series of high intensity, low pressure synthetic quartz mercury vapor discharge lamps. By utilizing the emission at 185 nm and 254 nm, ozone is generated. The high intensity output gives results quickly and facilitates a large cleaning area.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"UV Ozone Cleaner Illumination Area\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/uv-ozone-cleaner-tray-square.jpg?v=1670229166\u0026amp;width=190\u0026amp;height=190\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eLarge Cleaning Area\u003c\/p\u003e\n\u003cp\u003eThe tray can accommodate wafers up to 153 mm (6\") in diameter and 12 mm (0.47\") in thickness for a wide array of samples, including:\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eMicroscope slides\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eDiced substrates\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003ePetri dishes\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eAFM tips\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Simple To Use UV Ozone Cleaner\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/uv-ozone-cleaner-substrate-tray-square.jpg?crop=center\u0026amp;width=190\u0026amp;height=190\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eSimple to Use Interface\u003c\/p\u003e\n\u003cp\u003eThe bright LCD display and tactile keypad provide a simple interface.\u003c\/p\u003e\n\u003cp\u003eThe integrated software continuously monitors the temperature inside the system and gives readings for the tray, UV lamp, and electronics. This makes it easy to make sure that delicate samples do not overheat.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"Designed for safety\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/uv-ozone-cleaner-open-tray-substrates-square.jpg?crop=center\u0026amp;width=190\u0026amp;height=190\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eDesigned with Safety in Mind\u003c\/p\u003e\n\u003cp\u003eOur system adheres to BS EN 61010-1:2010 standards alongside EMC, Low Voltage, and RoHS CE directives. Smart safety features include an integrated safety interlock which keeps the lamp off while the tray is open. Plus, a thermal cutoff is triggered if the temperature detected by any of the internal sensors is too high.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eUV Ozone Cleaner Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/UV_Ozone_cleaner.jpg?width=1620\" title=\"UV Ozone Cleaner\"\u003e \u003cimg alt=\"UV Ozone Cleaner\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/UV_Ozone_cleaner.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/UV_Ozone_cleaner_substrate.jpg?width=1620\" title=\"Removing substrates from UV Ozone Cleaner tray\"\u003e \u003cimg alt=\"Removing substrates from UV Ozone Cleaner tray\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/UV_Ozone_cleaner_substrate.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/UV_Ozone_cleaning_tray.jpg?width=1620\" title=\"UV Ozone Cleaning\"\u003e \u003cimg alt=\"UV Ozone Cleaning\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/UV_Ozone_cleaning_tray.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/UV_Ozone_Cleaner_tray_slot.jpg?width=1620\" title=\"Open tray area\"\u003e \u003cimg alt=\"Open tray area\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/UV_Ozone_Cleaner_tray_slot.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/UV_Ozone_cleaner_2.jpg?width=1620\" title=\"UV Ozone Cleaner in use\"\u003e \u003cimg alt=\"UV Ozone Cleaner in use\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/UV_Ozone_cleaner_2.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca class=\"carousel-left-control\" role=\"button\"\u003e \u003csvg class=\"icon icon-chevron-left\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious\u003c\/span\u003e \u003c\/a\u003e \u003ca class=\"carousel-right-control\" role=\"button\"\u003e \u003csvg class=\"icon icon-chevron-right\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"replacement-service\"\u003eUV Lamp Replacement Service\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eFor safe and successful bulb replacement, simply contact us to place an order for a new bulb and send your Ossila system back to us. Once it arrives in house, we can replace the bulb and have it ready for return within 48 hours. Within this service, we will:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReplace the UV bulb\u003c\/li\u003e\n\u003cli\u003eFully test all components to ensure they are working as intended\u003c\/li\u003e\n\u003cli\u003eCheck that all components meet the required safety standard\u003c\/li\u003e\n\u003cli\u003eSafely dispose of the old bulb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe recommend bulb replacement is undertaken by us rather than installing the bulb yourself as the system operates at high voltage. Incorrect assembly of the unit after a bulb replacement can be dangerous. Please feel free to contact us if you have any questions about this.\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/which-uv-ozone-features-are-needed\"\u003e\u003cimg alt=\"UV Ozone Cleaner features\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/uv-ozone-cleaner-open-tray-substrates-square.jpg?crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/which-uv-ozone-features-are-needed\"\u003eWhich UV Ozone Cleaner Features do I Need?\u003c\/a\u003e\n\u003cp\u003eIt is always important to assess the necessity and applicability of additional features in your experimental setup. The Ossila UV Ozone Cleaner is built with simplicity and efficacy in mind.\u003c\/p\u003e\n\u003ca href=\"\/pages\/which-uv-ozone-features-are-needed\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Type B (US)","offer_id":37813667457,"sku":"L2002A3-US","price":2400.0,"currency_code":"GBP","in_stock":true},{"title":"Type F (EU)","offer_id":37813667393,"sku":"L2002A3-EU","price":2400.0,"currency_code":"GBP","in_stock":true},{"title":"Type G (UK)","offer_id":1200242961,"sku":"L2002A3-UK","price":2400.0,"currency_code":"GBP","in_stock":true},{"title":"Type I (AU)","offer_id":37813667521,"sku":"L2002A3-AU","price":2400.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/uv-ozone-cleaner-featured-image.jpg?v=1768823156"},{"product_id":"tips-pentacene","title":"TIPS-Pentacene","description":"\u003ch2 id=\"product-oneliner\"\u003eHigh Purity p-Type Organic Semiconductor\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eExcellent hole mobility and air stability\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eTIPS-Pentacene is tri-isopropylsilyly-ethynyl (TIPS) substituted pentacene at 6- and 13-positions of the conjugated core. The substituted TIPS functional groups extend the conjugation further to the branches to provide further stability, enhance solubility for solution processing for low-cost and large-area fabrication of organic thin-film transistors (OTFTs).\u003c\/p\u003e\n\u003cp\u003eTIPS pentacene has been developed as a \u003cem\u003ep-\u003c\/em\u003etype organic semiconductor, and demonstrates high hole mobility and excellent air stability with great solution processability. The substitution of two bulky side groups can not only significantly enhance the solubility of TIPS-pentacene in most of the common solvents but also prevent the middle acene from oxidation and degradation. The tri-isopropylsilyly-ethynyl side groups can also interrupt the edge-to-face interaction of the aromatic ring to avoid the herringbone packing motif in neat pentacene. The ethynyl groups keeps the bulky side tri-isopropylsilyly groups away from the aromatic ring to allow π-π stacking between adjacent TIPS pentacene molecules.\u003c\/p\u003e\n\u003cp\u003eIn general, polymer\/TIPS pentacene blends have been used to improve film morphology and reduce crystal misorientation since TIPS-pentacene crystalline films are highly anisotropic, which could lead to significant variations in device performance.\u003c\/p\u003e\n\u003cp\u003eA high-purity TIPS-Pentacene for use in organic field-effect transistors (OFETs). TIPS-Pentacene is widely used as a high performance small molecule for OFET applications, with a mobility in excess of 1 cm\u003csup\u003e2\u003c\/sup\u003e\/Vs having being achieved in the literature. It has excellent solubility in a range of common organic solvents, and a good ambient stability - making it easy to process into devices. Ossila's TIPS-pentacene has been produced with a purity of \u0026gt;99.9%.\u003c\/p\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cimg alt=\"TIPS-Pentacene from Ossila was used in a high-impact paper (IF 18.81)\" class=\"float-left no-margin-bottom\" height=\"45\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/review-paper-icon.png?width=40\" width=\"40\"\u003e\n\u003cp class=\"no-margin\"\u003eTIPS-Pentacene from Ossila was used in the high-impact paper (IF 18.81), \u003ca class=\"text-italics\" href=\"https:\/\/doi.org\/10.1002\/adfm.201501381\" rel=\"nofollow\" target=\"_blank\"\u003eSelf-Assembled, Millimeter-Sized TIPS-Pentacene Spherulites Grown on Partially Crosslinked Polymer Gate Dielectric\u003c\/a\u003e, H. Yoo et al., Adv. Funct. Mater., 3658-3665 (2015); DOI: 10.1002\/adfm.201501381.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003ePlease note that TIPS-Pentacene is unavailable to buyers in the USA. Any incoming orders from the USA for TIPS-Pentacene will not be processed.\u003c\/p\u003e\n\u003cp\u003eOld product code M151 was upgraded to new product code M0151.\u003c\/p\u003e\n\u003ch2\u003eGeneral Information\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFull Name\u003c\/th\u003e\n\u003ctd\u003e6,13-Bis(triisopropylsilylethynyl)pentacene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSynonyms\u003c\/th\u003e\n\u003ctd\u003eTIPS-pentacene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCAS Number\u003c\/th\u003e\n\u003ctd\u003e373596-08-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eChemical Formula\u003c\/th\u003e\n\u003ctd\u003eC\u003csub\u003e44\u003c\/sub\u003eH\u003csub\u003e54\u003c\/sub\u003eSi\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMolecular Weight\u003c\/th\u003e\n\u003ctd\u003e639.07 g\/mol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSolvents\u003c\/th\u003e\n\u003ctd\u003eAnisole, butylbenzene, chlorobenzene, chloroform, dichlorobenzene, tetrahydrofuran, toluene, xylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eClassification \/ Family\u003c\/th\u003e\n\u003ctd\u003eMolecular semiconductors, Small molecule semiconductor, Organic Field-Effect Transistors (OFETs), soluble semiconductor materials, Pentacene derivatives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePurity\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 99 % (HPLC)\u003cbr\u003e\u0026gt; 99% (\u003csup\u003e1\u003c\/sup\u003eH-NMR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMelting Point\u003c\/th\u003e\n\u003ctd\u003e259 °C (DSC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAppearance\u003c\/th\u003e\n\u003ctd\u003eDark blue solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eChemical Structure\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tips-pentacene-373596-08-8-chemical-structure-body.png\" title=\"M151 Chemical structure of TIPS-pentacene\" target=\"_blank\"\u003e\u003cimg alt=\"Chemical structure of TIPS-pentacene\" height=\"240\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tips-pentacene-373596-08-8-chemical-structure-body.png?height=240\" width=\"320\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eChemical structure of TIPS-pentacene, CAS 373596-08-8\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eCharacterization\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp class=\"pad-top-half-height\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tips-pentacene-hplc.jpg\" target=\"_blank\"\u003e\u003cimg alt=\"HPLC data\" height=\"20\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px; height: 22px;\" width=\"20\"\u003eHPLC data\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pad-top-half-height\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tips-pentacene-1h-nmr.jpg\" target=\"_blank\"\u003e\u003cimg alt=\"NMR trace\" height=\"20\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px; height: 22px;\" width=\"20\"\u003eNMR trace\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pad-top-half-height\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/TIPS-pentacene-DSC.png\" target=\"_blank\"\u003e\u003cimg alt=\"\u0026gt;DSC trace\" height=\"20\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px; height: 22px;\" width=\"20\"\u003eDSC trace\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eOFET Fabrication Procedure\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eAbstract\u003c\/h3\u003e\n\u003cp\u003eWe have achieved a mobility of approximately 0.92 cm\u003csup\u003e2\u003c\/sup\u003e\/Vs using TIPS-Pentacene for top contact OFETs with a drop casting protocol. The TIPS-Pentacene film is obtained through slow crystallization growth at high temperature (50°C), in solvent saturated ambient, over silicon oxide substrates treated with phenyl-terminated silane molecules.\u003c\/p\u003e\n\u003cdiv class=\"expandable\" id=\"ofet-fabrication\"\u003e\n\u003ch3\u003eResults\u003c\/h3\u003e\n\u003cp\u003eThe image below depicts the best performance OFET, showing how the boundaries of the crystals forming the crystallite domain have boundaries parallel to the channel length. Cracks perpendicular to the growth direction are also clearly visible. These cracks act as defects (bottlenecks for charge transport) and must be minimized in order to obtain high-performing OFETs.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"TIPS pentacene OFET crystals\" height=\"187\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tips-pentacene-crystals-ofet-device.png?width=250\" width=\"250\"\u003e \u003cimg alt=\"TIPS pentacene crystals across OFET channel\" height=\"187\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tips-pentacene-crystals-ofet-channel.png?width=250\" style=\"float: none;\" width=\"250\"\u003e\n\u003cfigcaption\u003eAligned TIPS-Pentacene crystalline domains.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFET measurements\u003c\/h3\u003e\n\u003cp\u003eThe table below summarizes the mobility and threshold voltage for the three PTES-treated substrates, taking an average of 75% of the 15 OFET devices to minimize the maximum and minimum outliers.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDevices Measured\u003c\/th\u003e\n\u003cth\u003eMobility (cm\u003csup\u003e2\u003c\/sup\u003e\/Vs)\u003c\/th\u003e\n\u003cth\u003e\n\u003cem\u003eV\u003c\/em\u003e\u003csub\u003eT \u003c\/sub\u003e(V)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e0.28 +\/- 0.06\u003c\/td\u003e\n\u003ctd\u003e-5.14 +\/- 2.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg alt=\"TIPS pentacene output characteristics\" height=\"249\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tips-pentacene-output-characteristics.png?width=270\" width=\"270\"\u003e \u003cimg alt=\"TIPS pentacene transfer characteristics\" height=\"247\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tips-pentacene-transfer-characteristics.png?width=270\" style=\"float: none;\" width=\"270\"\u003e\n\u003cfigcaption\u003eLeft: Output currents of the best performing top-contact OFET for six different gate voltages.\u003c\/figcaption\u003e\n\u003cfigcaption\u003eRight: Same device transfer characteristic in saturation mode (V\u003csub\u003eds\u003c\/sub\u003e = -40 V).\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDrop Casting Details\u003c\/h3\u003e\n\u003cp\u003eThe direction of the crystal growth, and therefore the orientation of the crystal axes (with respect to the channel length), can be controlled by imposing a preferential drying direction to the drop casted solution. This is achieved by positioning the substrate inside a Petri dish at a 3.5° angle with respect to the horizontal line of a perfectly flat hot plate. Substrates are placed inside the Petri dish in a manner such that the length of the channel is perpendicular to the receding direction of the drying solution. Drop casting is carried out using a pipette with the substrate at a temperature of 50°C. The lid was put back immediately afterwards to trap the solvent vapor and create a vapor-saturated condition inside the Petri dish.\u003c\/p\u003e\n\u003cp\u003eImages below taken of thin films of TIPS-pentacene deposited by spin casting and drop casting from toluene (10 mg\/ml) on SiO\u003csub\u003e2,\u003c\/sub\u003e showing the strong crystallization behavior in slow dried films.\u003c\/p\u003e\n\u003cdiv class=\"description col-xs-12\"\u003e\n\u003ctable style=\"width: 100%; border: 0px; background-color: white;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: white;\"\u003e\n\u003cfigure style=\"text-align: center;\"\u003e\u003cimg alt=\"TIPS pentacene small crystals from 1000 rpm spin cast film\" height=\"192\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tips-pentacene-1000-rpm.png?width=240\" style=\"float: none;\" width=\"240\"\u003e\n\u003cfigcaption\u003eTIPS-Pentacene, spin coated 1000 rpm\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/td\u003e\n\u003ctd style=\"background-color: white;\"\u003e\n\u003cfigure style=\"text-align: center;\"\u003e\u003cimg alt=\"TIPS pentacene medium crystals from 300 rpm spin cast film\" height=\"192\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tips-pentacene-300rpm.png?width=240\" style=\"float: none;\" width=\"240\"\u003e\n\u003cfigcaption\u003eTIPS-Pentacene, spin coated 300 rpm\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/td\u003e\n\u003ctd style=\"background-color: white;\"\u003e\n\u003cfigure style=\"text-align: center;\"\u003e\u003cimg alt=\"TIPS pentacene large crystals from drop cast film\" height=\"192\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tips-pentacene-dropcast.png?width=240\" style=\"float: none;\" width=\"240\"\u003e\n\u003cfigcaption\u003eTIPS-Pentacene, drop cast (covered)\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003eExperimental\u003c\/h3\u003e\n\u003ch4\u003eOFET device specifications\u003c\/h4\u003e\n\u003cp\u003eThis table shows details of the substrates used in this fabrication routine.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSubstrates\u003c\/th\u003e\n\u003ctd\u003eOssila \u003ca href=\"https:\/\/www.ossila.com\/products\/silicon-oxide-substrates\" title=\"silicon substrates for OFET test chips\"\u003esilicon\/silicon dioxide substrates (S146)\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSubstrate Size\u003c\/th\u003e\n\u003ctd\u003e20 x 15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGate Conductivity\u003c\/th\u003e\n\u003ctd\u003e1-30 Ω·cm (Boron doped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSilicon Oxide Thickness\u003c\/th\u003e\n\u003ctd\u003e300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice per Substrates\u003c\/th\u003e\n\u003ctd\u003eFive, common gate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel Length\u003c\/th\u003e\n\u003ctd\u003e30 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel Width\u003c\/th\u003e\n\u003ctd\u003e1000 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOFET Architecture\u003c\/th\u003e\n\u003ctd\u003eTop contact, bottom gate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSource-Drain Patterning\u003c\/th\u003e\n\u003ctd\u003eThermal evaporation using \u003ca href=\"https:\/\/www.ossila.com\/products\/ofet-source-drain-mask-low-density\" title=\"OFET source-drain shadow evaporation mask\"\u003eSource-Drain Deposition Mask for Low Density OFETs\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eTIPS-Pentacene solution preparation\u003c\/h4\u003e\n\u003cp\u003ePreparation of the stock solution took place in a glove box (O\u003csub\u003e2\u003c\/sub\u003e \u0026lt;\u0026lt; 10 ppm; H\u003csub\u003e2\u003c\/sub\u003eO). The solution used for drop casting was prepared only when needed. TIPS-pentacene is relatively resilient to oxidation at room temperature. However, long permanence in normal ambient condition (\u0026gt;24 hrs) can result in molecular degradation and increased water content of the solution.\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTIPS-pentacene dissolved in anhydrous toluene, 10 mg\/ml, to make stock solution\u003c\/li\u003e\n\u003cli\u003eThe stock solution is placed on a hotplate at 60°C for 1 hour at 1000 rpm with a magnetic stirrer\u003c\/li\u003e\n\u003cli\u003eSolution was then filtered with 0.45 µm filter into a new vial\u003c\/li\u003e\n\u003cli\u003eRequired amount was diluted with anhydrous toluene to 2 mg\/ml\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSubstrate cleaning\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1% Hellmanex III solution in hot DI water\u003c\/li\u003e\n\u003cli\u003eSonicate for 5 min in hot water\u003c\/li\u003e\n\u003cli\u003eRinse twice in hot water\u003c\/li\u003e\n\u003cli\u003eIPA, Sonicate 5 min in hot water\u003c\/li\u003e\n\u003cli\u003eRinse twice in DI water (cold)\u003c\/li\u003e\n\u003cli\u003eStore substrates in DI water\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/products\/uv-ozone-cleaner\" title=\"UV Ozone Cleaner for substrate cleaning\"\u003eUV Ozone treatment\u003c\/a\u003e for 5 min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSurface treatments\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePTES (Trichloro(phenethyl)silane) treatment: 3 mMol in toluene for 15 hrs in glove box at 90°C or, alternatively\u003c\/li\u003e\n\u003cli\u003ePTS (Trichloro(phenyl)silane) treatment: 3% in weight in toluene at 90°C for 15 hrs in glove box\u003c\/li\u003e\n\u003cli\u003eSubstrates rinsed twice in glove box with toluene, then blow dried and brought outside a glove box\u003c\/li\u003e\n\u003cli\u003eSonicated in toluene for 10 minutes and blow dried\u003c\/li\u003e\n\u003cli\u003eRinsed with 2 ml of acetone and blow dried\u003c\/li\u003e\n\u003cli\u003eRinsed with 2 ml of IPA and blow dried\u003c\/li\u003e\n\u003cli\u003ePut in glove box on hotplate at 150°C for 5 min\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTIPS-pentacene drop casting\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePipetted 50 μl of TIPS solution (2 mg\/ml) onto each substrate, which were sitting within a petri dish\u003c\/li\u003e\n\u003cli\u003eCovered with glass lid for 5 minutes on a hot plate at 50°C\u003c\/li\u003e\n\u003cli\u003eHot plate switched off and left to cool down to close to room temperature\u003c\/li\u003e\n\u003cli\u003eUsing cleanroom swabs wetted with toluene, wiped the substrates clean with the exception of the area over which the drain and source were to be deposited\u003c\/li\u003e\n\u003cli\u003eLoaded the substrates into the \u003ca href=\"https:\/\/www.ossila.com\/products\/ofet-evaporation-stack-low-density\" title=\"Evaporation Stack for Low Density OFETs\"\u003eevaporation stack for low density OFETs\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDeposition of top contact gold\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLoaded Edwards Auto 306 thermal evaporator\u003c\/li\u003e\n\u003cli\u003eEvaporator left to pump down to low pressure (\u003cem\u003eca.\u003c\/em\u003e 2 x 10\u003csup\u003e-\u003csmall\u003e6\u003c\/small\u003e\u003c\/sup\u003e mBar)\u003c\/li\u003e\n\u003cli\u003eDeposited 80 nm of gold on TIPS-pentacene-coated substrates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOFETs were measured using an Ossila \u003ca href=\"https:\/\/www.ossila.com\/products\/ofet-test-board-low-density\" title=\"OFET measurement test board\"\u003eTest Board for Low-Density OFETs (E222)\u003c\/a\u003e under air.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tips-pentacene-fabrication-guide-v2.pdf\"\u003eDownload the full fabrication report\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbutton class=\"anchor expand-link\" data-expand-target=\"ofet-fabrication\" data-toggle-text=\"Hide all fabrication details\" type=\"button\"\u003eView all fabrication details\u003c\/button\u003e\u003c\/p\u003e","brand":"Ossila","offers":[{"title":"100 mg","offer_id":50442534125784,"sku":"M0151B1-100mg","price":110.0,"currency_code":"GBP","in_stock":true},{"title":"250 mg","offer_id":51258512834776,"sku":"M0151B1-250mg","price":230.0,"currency_code":"GBP","in_stock":true},{"title":"500 mg","offer_id":1200243673,"sku":"M0151B1-500mg","price":410.0,"currency_code":"GBP","in_stock":true},{"title":"1 g","offer_id":19252737966176,"sku":"M0151B1-1g","price":660.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/tips-pentacene-373596-08-8-chemical-structure-title.png?v=1745490615"},{"product_id":"mai-methyl-ammonium-iodide","title":"Methylammonium Iodide (MAI)","description":"\u003ch2 id=\"product-oneliner\"\u003eMethylammonium iodide, precursor for the synthesis of perovskites\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eHigh quality, low price, and available online for fast and secure dispatch\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#msds\"\u003eMSDS\u003c\/a\u003e | \u003ca href=\"#pricing\"\u003ePricing and Options\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eMethylammonium iodide (MAI), CAS number 14965-49-2, also referred to as methylamine hydroiodide, is a precursor for the synthesis of organic-inorganic hybrid perovskites for use in FETs, LEDs and PVs.\u003c\/p\u003e\n\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Perovskite precursor material\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Lab_Proof.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003ePerovskite precursor material\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003efor the synthesis of organic-inorganic hybrid perovskite\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 margin-top text-center\"\u003e\n\u003cimg alt=\"Worldwide shipping\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/free-shipping.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eWorldwide shipping\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eQuick and reliable shipping\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"electronic applications\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Voltage.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eUsed in multiple electronic applications\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eincluding FETs, LEDs, and PVs\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"High purity\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2D-Materials-Icons_-Purity.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eHigh purity\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003e\u0026gt; 99.9% non-recrystallized and recrystallized grade available\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cimg alt=\"Methylammonium Iodide (MAI) from Ossila was used in the high-impact paper (IF 30.85)\" class=\"float-left no-margin-bottom\" height=\"56\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/review-paper-icon.png?v=1613159723\u0026amp;width=50\" width=\"50\"\u003e\n\u003cp class=\"no-margin\"\u003eMethylammonium Iodide (MAI) from Ossila was used in the high-impact paper (IF 30.85), \u003ca class=\"text-italics\" href=\"https:\/\/doi.org\/10.1002\/adma.201603016\" rel=\"nofollow\" target=\"_blank\"\u003eStrontium Insertion in Methylammonium Lead Iodide: Long Charge Carrier Lifetime and High Fill-Factor Solar Cells\u003c\/a\u003e, D. Pérez-del-Rey et al., Adv. Mater., 28, 9839-9845 (2016); DOI: 10.1002\/adma.201603016.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eChemical Formula\u003c\/th\u003e\n\u003ctd\u003eCH\u003csub\u003e6\u003c\/sub\u003eIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSynonyms\u003c\/th\u003e\n\u003ctd\u003eMethylamine hydroiodide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCAS No.\u003c\/th\u003e\n\u003ctd\u003e14965-49-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eChemical Name\u003c\/th\u003e\n\u003ctd\u003eMethylammonium iodide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePhysical Aappearance\u003c\/th\u003e\n\u003ctd\u003eWhite, crystalline solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePurity\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eM272: 99.9% (ICP-OES)\u003c\/p\u003e\n\u003cp\u003eM271: \u0026gt;99.9% (further purified by double recrystallization from 99.9% grade in ethanol)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMolecular Weight\u003c\/th\u003e\n\u003ctd\u003e158.97 g\/mol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eRecommended Solvents (for perovskite synthesis)\u003c\/th\u003e\n\u003ctd\u003eDMF, DMSO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eChemical Structure\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/methyl-ammonium-iodide-structure-body.png\" rel=\"noopener noreferrer\" target=\"_blank\" title=\"Methyl-ammonium iodide (MAI) chemical structure\"\u003e \u003cimg alt=\"Methyl-ammonium iodide (MAI) chemical structure\" height=\"196\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/methyl-ammonium-iodide-structure-body.png\" width=\"240\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eMethylammonium Iodide (MAI) chemical structure\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eNMR spectrum\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure\u003e\u003ca alt=\"Methylammonium Iodide NMR Spectrum\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/mai_nmr-spectrum.png\"\u003e \u003cimg alt=\"MAI 1H-NMR spectrum\" height=\"295.219\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/mai_nmr-spectrum.png?v=1718874363\" width=\"848.328\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003e\u003cem\u003e\u003csup\u003e1\u003c\/sup\u003eH NMR spectrum of methylammonium iodide in DMSO (500 MHz). The peaks centered around 2.5 and 3.3 ppm are residual DMSO and water impurities respectively from the deuterated NMR solvent. (Click the image for a larger version)\u003c\/em\u003e\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch2 id=\"msds\"\u003eMSDS Documentation\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/msds\/mai-methyl-ammonium-iodide.pdf\" target=\"_blank\" title=\"Methylammonium Iodide MSDS Sheet\"\u003e\u003cimg alt=\"Methylammonium Iodide MSDS\" class=\"msds-icon\" height=\"39\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/product-downloads-msds.svg\" width=\"30\"\u003eMethylammonium Iodide MSDS sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eDue to the high purity of the methylammonium iodide (\u0026gt;99.9% recrystallized), it should be noted that its solubility is reduced within dimethyl formamide and dimethyl sulfoxide. This reduced solubility is due to the removal of trace amounts of residual hydroiodic acid (HI) used during the synthesis and purification of the material. This can potentially have an impact upon the performance of solar cells leading to a reduction in maximum power conversion efficiency achievable. Adding fixed concentrations of hydroiodic acid to perovskite solutions can allow for the improvement of device metrics\u003csup\u003e[1-3]\u003c\/sup\u003e. Using high-purity precursor materials allows for accurate addition of amounts of hydroiodic acid giving higher reproducibility to experiments. It is recommended that between 1% and 10% hydroiodic acid is used with high-purity methylammonium iodide to achieve optimal device performance. The amount required depends on the precursors used, solution concentration, solvent used, and processing environment. Therefore, this will need to be adjusted for each individual laboratory and process.\u003c\/p\u003e\n\u003cp\u003eFor simpler ink fabrication, it is recommended that the lower-purity methylammonium iodide (99.9% non-recrystallized) is used.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cem\u003eHysteresis-less inverted CH\u003csub\u003e3\u003c\/sub\u003eNH\u003csub\u003e3\u003c\/sub\u003ePbI\u003csub\u003e3\u003c\/sub\u003e planar perovskite hybrid solar cells with 18.1% power conversion efficiency, \u003c\/em\u003eJ. H. Heo et al., Energ. Environ. Sci., 8, 602-1608 (2015); DOI: 10.1039\/C5EE00120J.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eA [2,2]paracyclophane triarylamine-based hole-transporting material for high performance perovskite solar cells, \u003c\/em\u003eS Park et al., J. Mater. Chem. A., 3, 24215-24220 (2015); DOI: 10.1039\/C5TA08417B.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eEnhanced optopelectronic quality of perovskite thin films with hydrophosphorous acid for planar heterojunction solar cells,\u003c\/em\u003e W. Zhang et al., Nat. Commun., 6, 10030 (2015); doi:10.1038\/ncomms10030.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cfigure\u003e\u003cimg alt=\"Methylammonium iodide (MAI) photo\" height=\"240\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/methyl-ammonium-iodide-photo.png?v=1726498467\u0026amp;width=240\" width=\"240\"\u003e\n\u003cfigcaption\u003eMethylammonium Iodide (MAI) powder\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eUsage details\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eReference devices - perovskite PVs\u003c\/h3\u003e\n\u003cp\u003eReference devices were made to assess the performance of perovskite (MAI:PbCl\u003csub\u003e2\u003c\/sub\u003e) based devices with the below structure. These were fabricated in air prior to spincasting the fullerene layer in a N\u003csub\u003e2\u003c\/sub\u003e glove box Substrates were then transferred to a vacuum chamber where a composite metal cathode was thermally evaporated. Finally, substrates were encapsulated inside the glove box before measurements were taken under ambient conditions.\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003e\u003cstrong\u003eGlass \/ ITO (100 nm) \/ \u003ca href=\"https:\/\/www.ossila.com\/products\/pedot-pss-ai-4083\" title=\"AI 4083 PEDOT:PSS\"\u003ePEDOT:PSS AI 4083\u003c\/a\u003e (30 nm) \/ MAI:PbCl\u003csub\u003e2\u003c\/sub\u003e \/ \u003ca href=\"https:\/\/www.ossila.com\/products\/pc70bm\" title=\"PC70BM, PC71BM\"\u003ePC\u003csub\u003e70\u003c\/sub\u003eBM\u003c\/a\u003e \/ Ca (5 nm) \/ Al (100 nm)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor generic details please see the \u003ca alt=\"Perovskite Fabrication Guide\" href=\"\/pages\/perovskite-solar-cells-fabrication-guide-using-i101-perovskite-precursor-ink\" title=\"Perovskite fabrication guide\"\u003efabrication guide\u003c\/a\u003e and \u003ca alt=\"Perovskite Video Guide\" href=\"\/pages\/video-guide-to-make-efficient-air-processed-perovskite-devices\" title=\"How to make perovskites video\"\u003evideo\u003c\/a\u003e. For specific details please see the below condensed fabrication report which details the optical modeling and optimization of the multilayer stack.\u003c\/p\u003e\n\u003cp\u003eThe perovskite solution (MAI:PbCl\u003csub\u003e2\u003c\/sub\u003e at a molar ratio of 3:1) was made in dimethylformamide (DMF) at a concentration of 664 mg\/ml. It was found to be critical that both materials were mixed dry prior to adding the solvent in order to achieve such high concentration.\u003c\/p\u003e\n\u003cp\u003eFor maximum efficiency, the active layer thickness was achieved from spin casting the heated solution (70°C) onto a hot \u003ca href=\"https:\/\/www.ossila.com\/products\/pedot-pss-ai-4083\" title=\"AI 4083 PEDOT:PSS\"\u003ePEDOT:PSS AI 4083\u003c\/a\u003e substrate (90°C) at a spin speed of 5000 rpm for 30s. The films were then placed back onto the hotplate (90°C) for 2 hrs. The data below shows the maximum performance achieved from non-optimized conditions.\u003c\/p\u003e\n\u003cp\u003eOverall, the average efficiency after 5 mins light soaking was 8.89% (9.57% maximum) from MAI:PbCl\u003csub\u003e2\u003c\/sub\u003e based devices. Hysteresis was observed to be quite significant, with sweeps running from positive to negative bias presenting the best efficiencies (hereby referred to as reverse sweeps).\u003c\/p\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/i101-perovskite-ink-jv-curve.svg?v=1726498849\" target=\"_blank\"\u003e\u003cimg alt=\"I101 perovskite ink J-V curve\" height=\"360\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/i101-perovskite-ink-jv-curve.svg?v=1726498849\u0026amp;width=550\" width=\"550\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eJV curve under AM1.5 irradiation for a PV device based on MAI perovskite ink. Device characteristics were recorded on a reverse sweep.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/i101-perovskite-ink-efficiency.svg?v=1726498904\" target=\"_blank\"\u003e\u003cimg alt=\"I101 perovskite ink efficiency histogram\" height=\"349\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/i101-perovskite-ink-efficiency.svg?v=1726498904\u0026amp;width=550\" width=\"550\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eDistribution in device efficiencies recorded for a typical process run. Data taken from 5 substrates containing 30 pixels. 10 pixels having low operational efficiency resulting from their proximity to the edge of the device substrate were removed from this analysis.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eFabrication\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSubstrates and cleaning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePixelated Cathode substrates (S171) or Photovoltaic (8 Pixel) Substrates\u003c\/li\u003e\n\u003cli\u003e5 minutes sonication in hot 1% \u003ca alt=\"Hellmanex III Cleaning Solution\" href=\"\/products\/hellmanex-iii\" title=\"Hellmanex III for critical cleaning\"\u003eHellmanex III\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e1x boiling DI dump rinse, 1x cold dump rinse\u003c\/li\u003e\n\u003cli\u003e5 minutes sonication in warm IPA\u003c\/li\u003e\n\u003cli\u003e2x DI cold dump rinse\u003c\/li\u003e\n\u003cli\u003eStored in DI for 1hr\u003c\/li\u003e\n\u003cli\u003e5 minutes sonication in hot 10% NaOH solution\u003c\/li\u003e\n\u003cli\u003e2x DI dump rinse\u003c\/li\u003e\n\u003cli\u003eN\u003csub\u003e2\u003c\/sub\u003e blow dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePEDOT:PSS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/products\/pedot-pss-ai-4083\" title=\"AI 4083 PEDOT:PSS\"\u003ePEDOT:PSS AI 4083\u003c\/a\u003e filtered through a 0.45 µm PES filter (C2009S1)\u003c\/li\u003e\n\u003cli\u003eSpin on heated substrates at 6000 rpm for 30s\u003c\/li\u003e\n\u003cli\u003eBake at 130°C after spin cast\u003c\/li\u003e\n\u003cli\u003eNote that the cathode strip was not wiped clean, this is to allow a consistent perovskite layer on top\u003c\/li\u003e\n\u003cli\u003eSubstrates held at a temperature of 90°C for spin casting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eActive layer solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOld stock solution (2 weeks old) of MAI:PbCl\u003csub\u003e2\u003c\/sub\u003e (3:1 molar ratio) made at a concentration 664 mg\/ml in DMF\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eHeated for approx. 3 hrs at 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003eOld stock solution of PC\u003csub\u003e70\u003c\/sub\u003eBM, 50 mg\/ml in CB\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eHeated for approx. 4 hrs at 70°C with \u003ca href=\"https:\/\/www.ossila.com\/products\/magnetic-stir-bars\" title=\"Magnetic Stir Bars, Solvent Safe PTFE Coated\"\u003estir bar\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eActive layers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDevices spun onto hot substrate at 5000 rpm using 25 µl dynamic dispense for 30s\u003c\/li\u003e\n\u003cli\u003ePlaced immediately onto hotplate at 90°C for 2 hrs\u003c\/li\u003e\n\u003cli\u003eCathode wipe with dry cotton bud once all substrates were spun\u003c\/li\u003e\n\u003cli\u003eFilms started with a bright yellow color\u003c\/li\u003e\n\u003cli\u003eChanged to a dark grey color during thermal annealing process\u003c\/li\u003e\n\u003cli\u003eTransferred to a N\u003csub\u003e2\u003c\/sub\u003e glove box\u003c\/li\u003e\n\u003cli\u003ePCBM layer was spun at 1000 rpm for 30s, 20 µl dynamic dispense\u003c\/li\u003e\n\u003cli\u003eCB cathode wipe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEvaporation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLeft in vacuum chamber overnight and evaporated with the below parameters.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e5 nm Ca at 0.2 Å\/s\u003c\/li\u003e\n\u003cli\u003e100 nm Al at 1.5 Å\/s\u003c\/li\u003e\n\u003cli\u003eDeposition pressure 1e-6 mbar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEncapsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAs standard using Ossila EE1, 30 mins UV in MEGA LV101\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJV sweeps taken with source-meter\u003c\/li\u003e\n\u003cli\u003eIllumination by solar simulator with 100 mW\/cm\u003csup\u003e2\u003c\/sup\u003e AM1.5 output\u003c\/li\u003e\n\u003cli\u003eNREL certified silicon reference cell used to calibrate\u003c\/li\u003e\n\u003cli\u003eLamp current: 7.8 A\u003c\/li\u003e\n\u003cli\u003eSolar output at start of testing: 1.00 suns at 23°C\u003c\/li\u003e\n\u003cli\u003eSolar output at end of testing: 1.00 suns at 25°C\u003c\/li\u003e\n\u003cli\u003eAir cooled substrates\u003c\/li\u003e\n\u003cli\u003eRoom temperature at start of testing : 25°C\u003c\/li\u003e\n\u003cli\u003eRoom temperature at end of testing: 25°C\u003c\/li\u003e\n\u003cli\u003eCalibrated aperture mask size: 0.256 mm\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe are continuously studying MAI and perovskites and expect to provide you with further information and optimized fabrication guides as we do so. Check back regularly or subscribe to our email newsletter for updates. In the meantime, please \u003ca href=\"\/pages\/contact-us\" title=\"Contact Ossila\"\u003econtact us\u003c\/a\u003e if you have any further questions.\u003c\/p\u003e\n\u003ch2 id=\"pricing\"\u003ePricing\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eGrade\u003c\/th\u003e\n\u003cth\u003eOrder Code\u003c\/th\u003e\n\u003cth\u003eQuantity\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e99.9% purity\u003c\/td\u003e\n\u003ctd\u003eM272\u003c\/td\u003e\n\u003ctd\u003e10 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"130\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e99.9% purity\u003c\/td\u003e\n\u003ctd\u003eM272\u003c\/td\u003e\n\u003ctd\u003e25 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"260\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e99.9% purity\u003c\/td\u003e\n\u003ctd\u003eM272\u003c\/td\u003e\n\u003ctd\u003e100 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"760\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e99.9% purity\u003c\/td\u003e\n\u003ctd\u003eM272\u003c\/td\u003e\n\u003ctd\u003e500 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"2300\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;99.9% recrystallized\u003c\/td\u003e\n\u003ctd\u003eM271\u003c\/td\u003e\n\u003ctd\u003e5 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"150\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;99.9% recrystallized\u003c\/td\u003e\n\u003ctd\u003eM271\u003c\/td\u003e\n\u003ctd\u003e10 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"230\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;99.9% recrystallized\u003c\/td\u003e\n\u003ctd\u003eM271\u003c\/td\u003e\n\u003ctd\u003e25 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"460\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNote: Looking for a bulk order (100 g or above)? Please \u003ca href=\"\/pages\/contact-us\" target=\"_blank\" title=\"contact us\"\u003econtact us\u003c\/a\u003e for a quote.\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"col-xs-12 button-col\"\u003e\n\u003cdiv class=\"card-box\"\u003e\n\u003ch3 class=\"h4\"\u003eHow to Make Efficient Perovskite Solar Cells in a Glove Box\u003c\/h3\u003e\n\u003cp\u003eVarious other perovksites and transport materials, along with references and examples of their uses, can be found on our \"Ultimate Guide to Perovskites\" page - but we thought it would be useful to demonstrate an example of how to make a PSC (that can acheive over 19% PCE), from start to finish. We've also tried to include some helpful tips to perfect your technique.\u003c\/p\u003e\n\u003ca href=\"\/pages\/how-to-make-perovskites-solar-cells-in-a-glovebox-part-2\"\u003eLearn more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Ossila","offers":[{"title":"\u003e99.9% purity - recrystallised \/ 5 g","offer_id":30366225596512,"sku":"M271-5g","price":150.0,"currency_code":"GBP","in_stock":true},{"title":"99.9% purity \/ 10 g","offer_id":30366225629280,"sku":"M272-10g","price":130.0,"currency_code":"GBP","in_stock":true},{"title":"\u003e99.9% purity - recrystallised \/ 10 g","offer_id":30366225662048,"sku":"M271-10g","price":230.0,"currency_code":"GBP","in_stock":true},{"title":"99.9% purity \/ 25 g","offer_id":30366225694816,"sku":"M272-25g","price":260.0,"currency_code":"GBP","in_stock":true},{"title":"\u003e99.9% purity - recrystallised \/ 25 g","offer_id":30366225727584,"sku":"M271-25g","price":460.0,"currency_code":"GBP","in_stock":true},{"title":"99.9% purity \/ 100 g","offer_id":30366225760352,"sku":"M272-100g","price":760.0,"currency_code":"GBP","in_stock":true},{"title":"99.9% purity \/ 500 g","offer_id":30366225793120,"sku":"M272-500g","price":2300.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/methyl-ammonium-iodide-structure.png?v=1736778171"},{"product_id":"spiro-ometad","title":"Spiro-OMeTAD (Spiro-MeOTAD)","description":"\u003ch2 id=\"product-oneliner\"\u003eSpiro-OMeTAD, high performance HTL material\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003ewith excellent electronic properties and processability for solar cells and OLEDs\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e |\u003ca href=\"#pricing\"\u003ePricing and Options\u003c\/a\u003e | \u003ca href=\"#literature\"\u003eLiterature and Reviews\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eSpiro-OMeTAD (or Spiro-MeOTAD), CAS number 207739-72-8, is one of the most studied and suitable \u003ca href=\"https:\/\/www.ossila.com\/collections\/transport-layer-materials\" title=\"Transport Layer Materials\"\u003ehole transport layer materials (HTL)\u003c\/a\u003e due to its facile implementation and high performance in organic-inorganic electronic devices. The spiro-linked molecule provides high glass transition temperature (\u003cem\u003eT\u003csub\u003eg\u003c\/sub\u003e\u003c\/em\u003e), morphological stability and easy processability while maintaining good electronic properties. Spiro-MeOTAD has been widely used in solid-state dye-sensitized solar cells (ssDSSC), organic light-emitting diodes (OLED), perovskite solar cells (PSCs) and polymer based organic solar cells (OSCs).\u003c\/p\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cimg alt=\"Ossila's Spiro-OMeTAD was used in a high impact paper (IF 29.37)\" class=\"float-left no-margin-bottom\" height=\"56\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/review-paper-icon.png?v=1613159723\u0026amp;width=50\" width=\"50\"\u003e\n\u003cp class=\"no-margin\"\u003eSpiro-OMeTAD (Spiro-MeOTAD) from Ossila was used in the high-impact paper (IF 29.37), \u003ca class=\"text-italics\" href=\"https:\/\/doi.org\/10.1002\/aenm.201800399\" rel=\"nofollow\" target=\"_blank\"\u003eInterfacing Pristine C60 onto TiO2 for Viable Flexibility in Perovskite Solar Cells by a Low-Temperature All-Solution Process\u003c\/a\u003e, Y. Zhou et al., Adv. Energy Mater., 1800399 (2018); DOI: 10.1002\/aenm.201800399; and paper (IF 39.714), \u003cspan class=\"title_heading\"\u003e\u003cem\u003e\u003ca href=\"https:\/\/doi.org\/10.1039\/C7EE03013D\" rel=\"nofollow\" target=\"_blank\" title=\"Spiro-ometad\"\u003e\u003cspan class=\"italic\"\u003eIn situ\u003c\/span\u003e simultaneous photovoltaic and structural evolution of perovskite solar cells during film formation\u003c\/a\u003e\u003c\/em\u003e, M. Alsari et al., Energy Environ. Sci., 11, 383-393 (2018); DOI: 10.1039\/C7EE03013D.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eHigh-purity Spiro-OMeTAD (Spiro-MeOTAD) is in stock now for immediate dispatch to institutions worldwide. Please \u003ca href=\"https:\/\/www.ossila.com\/pages\/contact-us\" title=\"Contact Us\"\u003econtact us\u003c\/a\u003e for bulk orders over 100 g.\u003c\/p\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Spirobifluorene hold transport layer material\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/All_Icons_CRYSTALS.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eSpirobifluorene hold transport layer material\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eexhibiting facile implementation and high performance in electronic devices\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 margin-top text-center\"\u003e\n\u003cimg alt=\"207739-72-8 Worldwide shipping\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/free-shipping.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eWorldwide shipping\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eQuick and reliable shipping\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"High glass transition temperature and morphological stability\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Enviroment_sensors.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eHigh glass transition temperature and morphological stability\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003efor facile coupling reactions\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"High purity 207739-72-8\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2D-Materials-Icons_-Purity.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eHigh purity\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003e99.5% (sublimed) and 99% (unsublimed)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"specifications\"\u003eGeneral Information\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCAS Number\u003c\/th\u003e\n\u003ctd\u003e207739-72-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMolecular Formula\u003c\/th\u003e\n\u003ctd\u003eC\u003csub\u003e81\u003c\/sub\u003eH\u003csub\u003e68\u003c\/sub\u003eN\u003csub\u003e4\u003c\/sub\u003eO\u003csub\u003e8\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFull Name\u003c\/th\u003e\n\u003ctd\u003e2,2',7,7'-Tetrakis[N,N-di(4-methoxyphenyl)amino]-9,9'-spirobifluorene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSynonyms\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eSpiro-OMeTAD\u003c\/p\u003e\n\u003cp class=\"no-margin\"\u003eSpiro-MeOTAD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eM\u003csub\u003ew\u003c\/sub\u003e\n\u003c\/th\u003e\n\u003ctd\u003e1225.43 g\/mol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eUV Absorption Max\u003c\/th\u003e\n\u003ctd\u003e306 nm, 385 nm (in CH\u003csub\u003e2\u003c\/sub\u003eCl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePL Max\u003c\/th\u003e\n\u003ctd\u003e429 nm (in CH\u003csub\u003e2\u003c\/sub\u003eCl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eHOMO \/ LUMO\u003c\/th\u003e\n\u003ctd\u003eHOMO = -5.0 eV, LUMO = -2.05 eV (HOMO - E\u003csub\u003eg\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003e\n\u003cem\u003eE\u003c\/em\u003e\u003csub\u003eg\u003c\/sub\u003e (optical)\u003c\/th\u003e\n\u003ctd\u003e2.95 eV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eChemical Structure\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spiro-ometad-207739-72-8-chemical-structure-body.png\" rel=\"noopener\" target=\"_blank\" title=\"spiro-ometad, 207739-72-8\"\u003e\u003cimg alt=\"spiro-ometad, 207739-72-8\" height=\"240\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spiro-ometad-207739-72-8-chemical-structure-body.png?height=240\" style=\"margin-bottom: 16px; float: none;\" width=\"320\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cfigcaption\u003eSpiro-OMeTAD chemical structure, CAS 207739-72-8\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePurity\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eSublimed: \u0026gt;99.5% (HPLC)\u003c\/p\u003e\n\u003cp class=\"no-margin\"\u003eUnsublimed: \u0026gt;99.0% (HPLC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMelting Point\u003c\/th\u003e\n\u003ctd\u003e240 °C (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eTGA\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;360 °C (0.5% weight loss)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAppearance\u003c\/th\u003e\n\u003ctd\u003eWhite to pale yellow powder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*Sublimation is a technique used to obtain ultra pure-grade chemicals. For more details about sublimation, please refer to the \u003ca href=\"https:\/\/www.ossila.com\/collections\/sublimed-materials\" title=\"Sublimed Materials\"\u003eSublimed Materials\u003c\/a\u003e .\u003c\/p\u003e\n\u003ch2\u003eCharacterization\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure\u003e\u003cimg alt=\"Spiro-OMeTAD HPLC trace\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spiro-ometad-hplc-purity.png?v=1718800486\"\u003e\n\u003cfigcaption\u003eHPLC trace and \u003csup\u003e1\u003c\/sup\u003eH-NMR spectrum for Spiro-OMeTAD with \u0026gt; 99.5% purity. \u003c!--Click image for higher resolution.--\u003e\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch2 id=\"pricing\"\u003ePricing\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eGrade\u003c\/th\u003e\n\u003cth width=\"20.6%\"\u003eOrder Code\u003c\/th\u003e\n\u003cth width=\"20.6%\"\u003eQuantity\u003c\/th\u003e\n\u003cth width=\"20.6%\"\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eUnsublimed (\u0026gt;99.0% purity)\u003c\/th\u003e\n\u003ctd\u003eM291\u003c\/td\u003e\n\u003ctd\u003e500 mg\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"210\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSublimed (\u0026gt;99.5% purity)\u003c\/th\u003e\n\u003ctd\u003eM292\u003c\/td\u003e\n\u003ctd\u003e500 mg\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"300\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eUnsublimed (\u0026gt;99.0% purity)\u003c\/th\u003e\n\u003ctd\u003eM291\u003c\/td\u003e\n\u003ctd\u003e1 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"350\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSublimed (\u0026gt;99.5% purity)\u003c\/th\u003e\n\u003ctd\u003eM292\u003c\/td\u003e\n\u003ctd\u003e1 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"480\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eUnsublimed (\u0026gt;99.0% purity)\u003c\/th\u003e\n\u003ctd\u003eM291\u003c\/td\u003e\n\u003ctd\u003e5 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"1560\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSublimed (\u0026gt;99.5% purity)\u003c\/th\u003e\n\u003ctd\u003eM292\u003c\/td\u003e\n\u003ctd\u003e5 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"2100\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eUnsublimed (\u0026gt;99.0% purity)\u003c\/th\u003e\n\u003ctd\u003eM291\u003c\/td\u003e\n\u003ctd\u003e10 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"2500\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSublimed (\u0026gt;99.5% purity)\u003c\/th\u003e\n\u003ctd\u003eM292\u003c\/td\u003e\n\u003ctd\u003e10 g\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"4000\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"literature\"\u003eReferences\u003c\/h2\u003e\n\u003chr\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003ci\u003eInterface engineering of highly efficient perovskite solar cells,\u003c\/i\u003e Huanping Zhou et al\u003ci\u003e.,\u003c\/i\u003e Science, V 34, p.546 (2014).\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003eSequential deposition as a route to high-performance perovskite-sensitized solar cells,\u003c\/i\u003e Julian Burschka et al., Nature, V499 p.316 (2013).\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003eNanostructured TiO\u003csub\u003e2\u003c\/sub\u003e \/CH\u003csub\u003e3\u003c\/sub\u003eNH\u003csub\u003e3\u003c\/sub\u003ePbI\u003csub\u003e3\u003c\/sub\u003e heterojunction solar cells employing spiro-OMeTAD\/Co-complex as hole-transporting material\u003c\/i\u003e, Jun Hong Noh et al., J. Mater. Chem. A, 1, 11842-11847, DOI: 10.1039\/C3TA12681A (2013).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cdiv class=\"expandable\" id=\"literature-and-reviews\"\u003e\n\u003ch3\u003eKey details from references\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e[1]: High efficiency perovskite solar cells with \u0026gt;19% efficiency. Doping regime specified via reference [2].\u003c\/li\u003e\n\u003cli\u003e[2]: \u003ca href=\"https:\/\/www.ossila.com\/products\/spin-coater\" title=\"Ossila Spin Coater\"\u003eSpin coated\u003c\/a\u003e spiro-MeOTAD in chlorobenzene doped with the below compounds doping ratio's specified in reference [3]:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.ossila.com\/products\/4-tert-butylpyridine\" title=\"4-tert-butylpyridine\"\u003e4-tert-butylpyridine\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.ossila.com\/products\/litfsi\" title=\"LiTFSI\"\u003elithium bis(trifluoromethylsul-phonyl)imide (LiTFSI)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003etris(2-(1H-pyrazol-1-yl)-4-tert-butylpyridine)cobalt(III) bis(tri-fluoromethylsulphonyl)imide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e[3]: Doped with the below concentrations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e50 mM spiro-OMeTAD in chlorobenzene\u003c\/li\u003e\n\u003cli\u003eCo(III)-complex (FK209) first dissolved into an acetonitrile stock solution prepared with concentrations in the range 4 to 33 mM before being added to the Spiro\/chlorobenzene solution\u003c\/li\u003e\n\u003cli\u003eFK209 stock solution mixed with Spiro\/chlorobenzene solution to give overall 7.7 mol% FK209 to Spiro-OMeTAD\u003c\/li\u003e\n\u003cli\u003eAlso doped with a stock solution of Li-bis(trifluoromethanesulfonyl)imide (Li-TFSI) at 170 mg and TBP at 46.6% by volume in acetonitrile\u003c\/li\u003e\n\u003cli\u003eSpin-coated at 3000 rpm for 30 s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbutton class=\"anchor expand-link\" data-expand-target=\"literature-and-reviews\" data-toggle-text=\"Hide Literature and Reviews\" type=\"button\"\u003eView Literature and Reviews\u003c\/button\u003e\u003c\/p\u003e\n","brand":"Ossila","offers":[{"title":"Unsublimed (\u003e99.0% purity) \/ 500 mg","offer_id":23115455681,"sku":"M291-500mg","price":210.0,"currency_code":"GBP","in_stock":true},{"title":"Unsublimed (\u003e99.0% purity) \/ 1 g","offer_id":1200243941,"sku":"M291-1g","price":350.0,"currency_code":"GBP","in_stock":true},{"title":"Unsublimed (\u003e99.0% purity) \/ 5 g","offer_id":51217227710680,"sku":"M291-5g","price":1560.0,"currency_code":"GBP","in_stock":true},{"title":"Unsublimed (\u003e99.0% purity) \/ 10 g","offer_id":20207134146656,"sku":"M291-10g","price":2500.0,"currency_code":"GBP","in_stock":true},{"title":"Sublimed (\u003e99.5% purity) \/ 500 mg","offer_id":23115492161,"sku":"M292-500mg","price":300.0,"currency_code":"GBP","in_stock":true},{"title":"Sublimed (\u003e99.5% purity) \/ 1 g","offer_id":1200243945,"sku":"M292-1g","price":480.0,"currency_code":"GBP","in_stock":true},{"title":"Sublimed (\u003e99.5% purity) \/ 5 g","offer_id":36710911836323,"sku":"M292-5g","price":2100.0,"currency_code":"GBP","in_stock":true},{"title":"Sublimed (\u003e99.5% purity) \/ 10 g","offer_id":36710925140131,"sku":"M292-10g","price":4000.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/spiro-ometad-207739-72-8-chemical-structure-title.png?v=1745402500"},{"product_id":"slot-die-coater","title":"Slot Die Coater","description":"\u003ch2 id=\"product-oneliner\"\u003eVersatile and Precise Slot Die Coating in Any Laboratory\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eScale up your research with an adaptable and low cost coating system\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#included\"\u003eIn the Box\u003c\/a\u003e | \u003ca href=\"#accessories\"\u003eAccessories\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eElevate your research with scalable coating technology. Our complete slot die coater features an integrated high-precision syringe pump and customizable head. With stage speeds ranging from 50 μm.s\u003csup\u003e-1\u003c\/sup\u003e to 75 mm.s\u003csup\u003e-1\u003c\/sup\u003e, an improved flow rate range (0.5–624 μl.s\u003csup\u003e-1\u003c\/sup\u003e for a 5 ml syringe), easy levelling, and large coating area, you have full control over the parameters critical to improving the uniformity of your films.\u003c\/p\u003e\n\u003cp\u003eThis slot die coater is suitable for users at any level. With intuitive software and adaptable design, you control the flow rate, coating speed, plate temperature, alignment, channel thickness, head height, multiple step programming, and more. Our modular accessories make the Ossila Slot Die Coater easy to tailor to your specific coating needs.\u003c\/p\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon-large-coating-area.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eUniform Thin Films\u003cbr\u003ewith Scalable Technology\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eOver a maximum coating\u003cbr\u003earea up to 150 cm\u003csup\u003e2\u003c\/sup\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Head_Heigfht_Control.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eAdjustable Gap Height\u003cbr\u003efor Easy Optimization\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003e2-point levelling with\u003cbr\u003eprecision micrometer heads\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2D-Materials-Icons_-Different_Forms.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eRange of Useful\u003cbr\u003eAdd-On Accessories\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eInterchangeable design to\u003cbr\u003eexpand coating capabilities\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Oprimised_Air_Speed.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eHigh Viscosity Model\u003cbr\u003efor Advanced Films\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eDesigned for viscosities of\u003cbr\u003e1,000 to 10,000 cPs\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure\u003e\u003cvideo class=\"widescreen\" controls=\"controls\" controlslist=\"nodownload\" crossorigin=\"\" height=\"477.172\" poster=\"https:\/\/cdn.ossila.com\/videos\/slot-die-coater-product-overview.jpg\" preload=\"none\" title=\"Slot Die Coater Product Overview video\" width=\"848.328\"\u003e\n\u003csource src=\"https:\/\/cdn.ossila.com\/videos\/slot-die-coater-product-overview.mp4\" type=\"video\/mp4\"\u003e\n\u003ctrack default=\"\" kind=\"subtitles\" label=\"English\" src=\"https:\/\/cdn.ossila.com\/videos\/slot-die-coater-product-overview.vtt\" srclang=\"en\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"Ossila Slot Die Coater Product Overview\",\n\"description\": \"Ossila Slot Die Coater Product Overview\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/slot-die-coater-product-overview.jpg\",\n\"uploadDate\": \"2023-11-29\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/slot-die-coater-product-overview.mp4\",\n\"duration\": \"PT0M56S\"\n}\n\u003c\/script\u003e\u003c\/figure\u003e\n\u003ch2 id=\"specification\"\u003eKey Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Hotplate Temperature\u003c\/th\u003e\n\u003ctd\u003e140 °C (284 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eStage Surface Roughness (RMS)\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;3 μm*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eStage Surface Flatness\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;20 μm*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eLinear Motion Levelness\u003c\/th\u003e\n\u003ctd\u003e0.05% variation (50 μm\/100 mm travel)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Stage Travel Length\u003c\/th\u003e\n\u003ctd\u003e150 mm (5.91\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMinimum Stage Speed\u003c\/th\u003e\n\u003ctd\u003e50 μm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Stage Speed\u003c\/th\u003e\n\u003ctd\u003e75 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Head to Substrate Travel Distance\u003c\/th\u003e\n\u003ctd\u003e13 mm (0.51\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMinimum Syringe Speed\u003c\/th\u003e\n\u003ctd\u003e6 μm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Syringe Speed\u003c\/th\u003e\n\u003ctd\u003e7.5 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"text-muted\"\u003e* Values determined at a stage temperature of 21 °C (69.8 °F).\u003c\/p\u003e\n\u003ch3\u003eSlot Die Heads\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003e\u003c\/th\u003e\n\u003cth width=\"30.9%\"\u003eStandard\u003c\/th\u003e\n\u003cth width=\"30.9%\"\u003eHigh Viscosity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eViscosity Range\u003c\/th\u003e\n\u003ctd\u003e0 – 1000 cPs\u003c\/td\u003e\n\u003ctd\u003e1000 – 10,000 cPs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eHead Inlet Connector\u003c\/th\u003e\n\u003ctd\u003eM5x0.8 Thread\u003c\/td\u003e\n\u003ctd\u003e1\/16 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eTubing and Connector Material\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003ePTFE tubing\u003c\/p\u003e\n\u003cp\u003eHigh-density PP Luer lock connectors\u003c\/p\u003e\n\u003cp\u003eStainless steel Luer lock to M5 thread connector\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1\/8 inch OD 2.1 mm ID stainless steel tubing\u003c\/p\u003e\n\u003cp\u003eStainless steel NPT compression fittings:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1\/8 NPT to 1\/8 tubing\u003c\/li\u003e\n\u003cli\u003e1\/16 NPT to 1\/8 tubing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSyringes\u003c\/th\u003e\n\u003ctd\u003e5 ml high-density PP disposable\u003c\/td\u003e\n\u003ctd\u003e5 ml precision stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003ca href=\"#specifications-continued\"\u003eSee more specifications\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eComplete Coating System\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Precise flow and optimized temperatures\" height=\"105\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Processing_icons_Stainless_steel_tray.svg\" style=\"margin-left: 5px;\" width=\"105\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eReliable Deposition and Drying\u003c\/p\u003e\n\u003cp\u003eMicro-step technology ensures precise solution flow, controlled start and end times, and a range of flow rates. Increase stage temperature to improve wetting and reduce the surface tension, as well as to optimize film drying. In high air flow conditions, control temperature offset to correct for differences between the substrate and stage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Full coating control\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Full_Control.svg\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eOptimize Coating Parameters\u003c\/p\u003e\n\u003cp\u003eUse the smooth, continuous motion across a range of speeds to alter the processing window, control film thickness, and find the best parameters for defect-free coatings. Vary the gap height, by adjusting the head relative to the stage, to improve the stability of the meniscus and alter the minimum wet film thickness.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Interchangeable slot die head accessories\" height=\"105\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Linear_Stage_Icons_Modular-design.svg\" style=\"margin-left: 12px;\" width=\"105\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eAdapt to Different Coating Setups\u003c\/p\u003e\n\u003cp\u003eWith an adaptable slot die head, use interchangeable stainless steel shims and meniscus guides to control channel thickness, guide your meniscus, and carefully control your thin film coating. Plus, our add-on accessories enable you to expand your coating capabilities with one system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eSlot Die Coater Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cvideo alt=\"Stage range of the slot die coater\" autoplay=\"autoplay\" class=\"widescreen\" height=\"477.17\" loop=\"loop\" muted=\"muted\" src=\"https:\/\/cdn.ossila.com\/videos\/slot-die-coater-stage-movement-loop.mp4\" title=\"Slot Die Coater stage range\" type=\"video\/mp4\" width=\"848.33\"\u003e\u003c\/video\u003e\u003c\/p\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Slot-Die-Coater.jpg?width=1620\" title=\"The Ossila Slot Die Coater\"\u003e \u003cimg alt=\"The Ossila Slot Die Coater\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Slot-Die-Coater.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \n\u003ca title=\"High Viscosity Slot Die Coater Setup\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/slot-die-high-viscosity-coater-setup.jpg?width=1024\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/slot-die-high-viscosity-coater-setup.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"High Viscosity Slot Die Coater Setup\"\u003e \u003c\/a\u003e\n\u003ca title=\"Slot Die Coater High Viscosity\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/slot-die-coater-high-viscosity-setup.jpg?width=1024\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/slot-die-coater-high-viscosity-setup.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"Slot Die Coater High Viscosity\"\u003e \u003c\/a\u003e\n\u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/SDC-thin-film.jpg?width=1620\" title=\"Slot die coater head\"\u003e \u003cimg alt=\"Slot die coater head\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/SDC-thin-film.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \n\u003ca title=\"Slot Die High Viscosity Coater\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/slot-die-coater-high-viscosity-syringe-closeup.jpg?width=1024\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/slot-die-coater-high-viscosity-syringe-closeup.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"Slot Die High Viscosity Coater\"\u003e \u003c\/a\u003e \n\u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-Slot-Die-Coater-Gauge.jpg?width=1620\" title=\"The slot die coater height gauges\"\u003e \u003cimg alt=\"The slot die coater height gauges\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-Slot-Die-Coater-Gauge.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-Slot-Die-Coater-Stage.jpg?width=1620\" title=\"The slot die coater stage mechanism\"\u003e \u003cimg alt=\"The slot die coater stage mechanism\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-Slot-Die-Coater-Stage.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \n\u003ca title=\"High Viscosity Slot Die Coater\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/slot-die-coater-high-viscosity-full-setup.jpg?width=1024\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/slot-die-coater-high-viscosity-full-setup.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"High Viscosity Slot Die Coater\"\u003e \u003c\/a\u003e\n\u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Slot-Die-Coater-Syringe-Pump.jpg?width=1620\" title=\"Integrated syringe pump setup\"\u003e \u003cimg alt=\"Integrated syringe pump setup\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Slot-Die-Coater-Syringe-Pump.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca class=\"carousel-left-control\" role=\"button\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-left\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious\u003c\/span\u003e \u003c\/a\u003e \u003ca class=\"carousel-right-control\" role=\"button\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-right\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"specifications-continued\"\u003eAdditional Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure\u003e\u003cimg alt=\"Ossila Slot Die Coater diagram\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/slot-die-coater-wireframe.svg\" width=\"424\"\u003e\u003c\/figure\u003e\n\u003ch3\u003eSlot Die Coater\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Head Width\u003c\/th\u003e\n\u003ctd\u003e100 mm (3.94\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eDC 24 V, 6.2 A, via 100 – 240 V 50\/60 Hz power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDimensions (D x W x H)\u003c\/th\u003e\n\u003ctd\u003e360 mm x 280 mm x 190 mm (14.2\" x 11\" x 7.5\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e10.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSlot Die Heads\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003e\u003c\/th\u003e\n\u003cth\u003e50 mm Head\u003c\/th\u003e\n\u003cth\u003e100 mm Head\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Coating Width\u003c\/th\u003e\n\u003ctd\u003e50 mm (1.97\")\u003c\/td\u003e\n\u003ctd\u003e100 mm (3.94\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCompatible Shims\u003c\/th\u003e\n\u003ctd\u003e5 – 50 mm coating width\u003c\/td\u003e\n\u003ctd\u003e75 – 100 mm coating width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCompatible Meniscus Guides\u003c\/th\u003e\n\u003ctd\u003e15 – 50 mm coating width\u003c\/td\u003e\n\u003ctd\u003e75 – 100 mm coating width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eUser Manuals\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/manuals\/slot-die-coater.pdf\" target=\"_blank\" title=\"Ossila Slot Die Coater user manual\"\u003e\u003cimg alt=\"Slot die coater user manual\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px;\" width=\"30\"\u003eSlot Die Coater Version 1 (L2005A1) user manual (legacy)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/manuals\/slot-die-coater-v2.pdf\" target=\"_blank\" title=\"Ossila Slot Die Coater user manual\"\u003e\u003cimg alt=\"Slot die coater user manual\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px;\" width=\"30\"\u003eSlot Die Coater Version 2 (L2005A2) user manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"included\"\u003eIn the Box\u003c\/h2\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eSlot die coating system\u003c\/li\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eStandard Slot Die Head:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStandard slot die head (with screw fittings and luer lock adapter)*\u003c\/li\u003e\n\u003cli\u003eSlot die coater PTFE tubing (pack of 5)*\u003c\/li\u003e\n\u003cli\u003e5 ml (6 ml) Norm-Ject Disposable Luer Lock Syringe (pack of 10)*\u003c\/li\u003e\n\u003cli\u003eMeniscus guide set*\u003c\/li\u003e\n\u003cli\u003eShim set*\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHigh Viscosity Slot Die Head:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh viscosity slot die head\u003c\/li\u003e\n\u003cli\u003eStainless steel tubing\u003c\/li\u003e\n\u003cli\u003e5 ml stainless steel syringe\u003c\/li\u003e\n\u003cli\u003eMeniscus guide set*\u003c\/li\u003e\n\u003cli\u003eHigh viscosity shim set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* Also available to be purchased separately\u003c\/p\u003e\n\u003ch2 id=\"accessories\"\u003eAccessories and Related Products\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e[[collection handle=\"equipment-accessories\" tags=\"slot die coater accessories\"]]\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/slot-die-coater-improved-design\"\u003e\u003cimg alt=\"Upgrading the Ossila Slot Die Coater\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Slot-Die-Coater.jpg?crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e\u003ca href=\"\/pages\/slot-die-coater-improved-design\"\u003eUpgrading the Ossila Slot Die Coater\u003c\/a\u003e\n\u003cp\u003eOur newest system has some important improvements that will enhance your coating processes.\u003c\/p\u003e\n\u003ca href=\"\/pages\/slot-die-coater-improved-design\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/setting-up-slot-die-coater\"\u003e\u003cimg alt=\"How to Set Up the Ossila Slot Die Coater\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-Slot-Die-Coater-Gauge.jpg?crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e\u003ca href=\"\/pages\/setting-up-slot-die-coater\"\u003eHow to Set Up the Ossila Slot Die Coater\u003c\/a\u003e\n\u003cp\u003eLearn how to \u003cspan\u003eset up the slot die coater and begin optimizing your large area thin film depositions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ca href=\"\/pages\/setting-up-slot-die-coater\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Ossila","offers":[{"title":"Standard 100 mm head \/ Type B (US)","offer_id":45300454293720,"sku":"L2005A2-100-US","price":7000.0,"currency_code":"GBP","in_stock":true},{"title":"Standard 100 mm head \/ Type F (EU)","offer_id":45300454260952,"sku":"L2005A2-100-EU","price":7000.0,"currency_code":"GBP","in_stock":true},{"title":"Standard 100 mm head \/ Type G (UK)","offer_id":45300454228184,"sku":"L2005A2-100-UK","price":7000.0,"currency_code":"GBP","in_stock":true},{"title":"Standard 100 mm head \/ Type I (AU)","offer_id":45300454326488,"sku":"L2005A2-100-AU","price":7000.0,"currency_code":"GBP","in_stock":true},{"title":"Standard 100 mm head \/ Type D\/H\/K\/L\/M\/N","offer_id":45384127676632,"sku":"L2005A2-100","price":7000.0,"currency_code":"GBP","in_stock":false},{"title":"Standard 50 mm head \/ Type B (US)","offer_id":45300454162648,"sku":"L2005A2-50-US","price":6750.0,"currency_code":"GBP","in_stock":true},{"title":"Standard 50 mm head \/ Type F (EU)","offer_id":45300454129880,"sku":"L2005A2-50-EU","price":6750.0,"currency_code":"GBP","in_stock":true},{"title":"Standard 50 mm head \/ Type G (UK)","offer_id":45300454097112,"sku":"L2005A2-50-UK","price":6750.0,"currency_code":"GBP","in_stock":true},{"title":"Standard 50 mm head \/ Type I (AU)","offer_id":45300454195416,"sku":"L2005A2-50-AU","price":6750.0,"currency_code":"GBP","in_stock":true},{"title":"Standard 50 mm head \/ Type D\/H\/K\/L\/M\/N","offer_id":45384127643864,"sku":"L2005A2-50","price":6750.0,"currency_code":"GBP","in_stock":false},{"title":"High viscosity 100 mm head \/ Type B (US)","offer_id":50898918932696,"sku":"L2005A2-100H-US","price":7500.0,"currency_code":"GBP","in_stock":true},{"title":"High viscosity 100 mm head \/ Type F (EU)","offer_id":50898918965464,"sku":"L2005A2-100H-EU","price":7500.0,"currency_code":"GBP","in_stock":true},{"title":"High viscosity 100 mm head \/ Type G (UK)","offer_id":50898918998232,"sku":"L2005A2-100H-UK","price":7500.0,"currency_code":"GBP","in_stock":true},{"title":"High viscosity 100 mm head \/ Type I (AU)","offer_id":50898919031000,"sku":"L2005A2-100H-AU","price":7500.0,"currency_code":"GBP","in_stock":true},{"title":"High viscosity 100 mm head \/ Type D\/H\/K\/L\/M\/N","offer_id":50898919063768,"sku":"L2005A2-100H","price":7500.0,"currency_code":"GBP","in_stock":true},{"title":"High viscosity 50 mm head \/ Type B (US)","offer_id":50898919096536,"sku":"L2005A2-50H-US","price":7250.0,"currency_code":"GBP","in_stock":true},{"title":"High viscosity 50 mm head \/ Type F (EU)","offer_id":50898919129304,"sku":"L2005A2-50H-EU","price":7250.0,"currency_code":"GBP","in_stock":true},{"title":"High viscosity 50 mm head \/ Type G (UK)","offer_id":50898919162072,"sku":"L2005A2-50H-UK","price":7250.0,"currency_code":"GBP","in_stock":true},{"title":"High viscosity 50 mm head \/ Type I (AU)","offer_id":50898919194840,"sku":"L2005A2-50H-AU","price":7250.0,"currency_code":"GBP","in_stock":true},{"title":"High viscosity 50 mm head \/ Type D\/H\/K\/L\/M\/N","offer_id":50898919227608,"sku":"L2005A2-50H","price":7250.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/slot-die-coater-50mm-head-product-photo.jpg?v=1760101479"},{"product_id":"ptaa-perovskites","title":"PTAA for Perovskite Applications","description":"\u003ch2 id=\"product-oneliner\"\u003eSubstantially Improve PCE of Perovskite Solar Cells\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eHigh quality HTL and EBL semiconducting material\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specifications\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#msds\"\u003eMSDS\u003c\/a\u003e | \u003ca href=\"#pricing\"\u003ePricing\u003c\/a\u003e | \u003ca href=\"#literature\"\u003eLiterature and Reviews\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003ePoly[bis(4-phenyl)(2,4,6-trimethylphenyl)amine (PTAA; CAS no. 1333317-99-9), a family member of poly(triaryl)amine, is an excellent hole-transporting and electron-blocking semiconducting material due to its electron-rich components. It is a popular choice for perovskite solar cell devices, due to its:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy processibility\u003c\/li\u003e\n\u003cli\u003eGood hole transport and electron blocking qualities\u003c\/li\u003e\n\u003cli\u003eHigh thermal stability\u003c\/li\u003e\n\u003cli\u003eUse in both regular and inverted devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cimg alt=\"Ossila's PTAA was used in a high impact paper (IF 30.85)\" class=\"float-left no-margin-bottom\" height=\"56\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/review-paper-icon.png?v=1613159723\u0026amp;width=50\" width=\"50\"\u003e\n\u003cp class=\"no-margin\"\u003ePTAA from Ossila was used in the high-impact paper (IF 30.85), \u003ca class=\"text-italics\" href=\"https:\/\/onlinelibrary.wiley.com\/doi\/abs\/10.1002\/adma.202002333\" rel=\"nofollow\" target=\"_blank\"\u003eMultiply Charged Conjugated Polyelectrolytes as a Multifunctional Interlayer for Efficient and Scalable Perovskite Solar Cells\u003c\/a\u003e, E. Jung et al., Adv. Mater., 2002333 (2020); DOI: 10.1002\/adma.202002333.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"PTAA (1333317-99-9) semiconducting material\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Powerful_Electronics-05.svg?v=1683217382\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eSemiconducting Material\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eHigh quality HTL and EBL material\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 margin-top text-center\"\u003e\n\u003cimg alt=\"Reduced electron-hole recombination\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Voltage.svg?v=1697197768\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eImprove Open Circuit Voltage\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003e(V\u003csub\u003eoc\u003c\/sub\u003e) and fill factor (FF)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"1333317-99-9 for perovskite applications\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2D-Materials-Icons_-Purity.svg?v=1698159365\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eHigh Quality\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eHigh quality \u0026amp; electron rich\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Hole-transport layer\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Five_Current_Range.svg?v=1697203063\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eHole-Transport Layer\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eImproved device performance\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv class=\"panel-body\"\u003eAlso available: \u003ca href=\"https:\/\/www.ossila.com\/products\/1f-ptaa\" title=\"1f-ptaa\" target=\"_blank\"\u003e1F-PTAA for perovskite and polymer solar cells\u003c\/a\u003e with improved \u003cem\u003eV\u003csub\u003eOC\u003c\/sub\u003e\u003c\/em\u003e and device performance, \u003ca href=\"https:\/\/www.ossila.com\/products\/ptaa\" title=\"ptaa for ofets\" target=\"_blank\"\u003ePTAA for organic field-effect transistor applications\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"specifications\"\u003eGeneral Information\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCAS Number\u003c\/th\u003e\n\u003ctd\u003e1333317-99-9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eChemical Formula\u003c\/th\u003e\n\u003ctd\u003e(C\u003csub\u003e21\u003c\/sub\u003eH\u003csub\u003e19\u003c\/sub\u003eN)\u003csub\u003en\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMolecular Weight\u003c\/th\u003e\n\u003ctd\u003ePlease see batch details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eHOMO \/ LUMO\u003c\/th\u003e\n\u003ctd\u003eHOMO 5.25 eV LUMO 2.30 eV [6]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSolubility\u003c\/th\u003e\n\u003ctd\u003eTHF, toluene, chloroform, chlorobenzene, dichlorobenzene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eRecommended Processing Solvents at 10mg\/ml\u003c\/th\u003e\n\u003ctd\u003eTHF (8mg\/ml)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSynonyms\u003c\/th\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePoly[bis(4-phenyl)(2,4,6-trimethylphenyl)amine\u003c\/li\u003e\n\u003cli\u003ePoly(triarylamine)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eClassification \/ Family\u003c\/th\u003e\n\u003ctd\u003ePolyamines, Hole-transport layer materials, Electron-blocking layer materials, Organic semiconducting materials, Organic photovoltaics, Polymer solar cells, OLED materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eChemical Structure\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ptaa-structure-body.jpg\" title=\"Chemical structure of PTAA, CAS no. 1333317-99-9\" target=\"_blank\"\u003e\u003cimg alt=\"Chemical structure of PTAA, CAS no. 1333317-99-9\" height=\"240\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ptaa-structure-body.jpg?height=240\" width=\"320\"\u003e \u003c\/a\u003e\n\u003cfigcaption\u003eChemical structure of PTAA, CAS no. 1333317-99-9\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eNotable Device Performances\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"20%\"\u003eJ\u003csub\u003eSC\u003c\/sub\u003e\n\u003c\/th\u003e\n\u003cth width=\"20%\"\u003eV\u003csub\u003eOC\u003c\/sub\u003e\n\u003c\/th\u003e\n\u003cth width=\"20%\"\u003eFF\u003c\/th\u003e\n\u003cth width=\"20%\"\u003ePCE\u003c\/th\u003e\n\u003cth width=\"20%\"\u003eRef\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16.5 mA\/cm\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.997 V\u003c\/td\u003e\n\u003ctd\u003e72.7%\u003c\/td\u003e\n\u003ctd\u003e12.0%\u003c\/td\u003e\n\u003ctd\u003e(Heo et al., 2013)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e21.84 mA\/cm\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.114\u003c\/td\u003e\n\u003ctd\u003e73.6%\u003c\/td\u003e\n\u003ctd\u003e17.91%\u003c\/td\u003e\n\u003ctd\u003e(Jeon et al., 2015)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24.7 mA\/cm\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.06\u003c\/td\u003e\n\u003ctd\u003e77.5%\u003c\/td\u003e\n\u003ctd\u003e20.2%\u003c\/td\u003e\n\u003ctd\u003e(Yang et al., 2015)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25.7 mA\/cm\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.118\u003c\/td\u003e\n\u003ctd\u003e82.3%\u003c\/td\u003e\n\u003ctd\u003e25.0%\u003c\/td\u003e\n\u003ctd\u003e(Li et al., 2022)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"msds\"\u003eMSDS Documentation\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/msds\/ptaa-perovskites.pdf\" title=\"PTAA (Perovskite) MSDS Sheet\" target=\"_blank\"\u003e\u003cimg alt=\"PTAA (Perovskite) MSDS\" class=\"msds-icon\" height=\"39\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/product-downloads-msds.svg\" width=\"30\"\u003ePTAA (Perovskite) MSDS sheet\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eBatch Details\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBatch\u003c\/th\u003e\n\u003cth\u003eMw\u003c\/th\u003e\n\u003cth\u003eMn\u003c\/th\u003e\n\u003cth\u003ePDI\u003c\/th\u003e\n\u003cth\u003eStock info\u003c\/th\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eM0511A10\u003c\/td\u003e\n\u003ctd\u003e12.6 kDa\u003c\/td\u003e\n\u003ctd\u003e5.5 kDa\u003c\/td\u003e\n\u003ctd\u003e2.29\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eM0511A14\u003c\/td\u003e\n\u003ctd\u003e10.7 kDa\u003c\/td\u003e\n\u003ctd\u003e8.2 kDa\u003c\/td\u003e\n\u003ctd\u003e1.29\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM0511A15\u003c\/td\u003e\n\u003ctd\u003e45.0 kDa\u003c\/td\u003e\n\u003ctd\u003e24.7 kDa\u003c\/td\u003e\n\u003ctd\u003e1.82\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"expandable\" id=\"past product detail\"\u003e\n\u003ch3\u003ePrevious Batch Details\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eBatch number\u003c\/th\u003e\n\u003cth width=\"15.45%\"\u003eM\u003csub\u003eW\u003c\/sub\u003e\n\u003c\/th\u003e\n\u003cth width=\"15.45%\"\u003eM\u003csub\u003en\u003c\/sub\u003e\n\u003c\/th\u003e\n\u003cth width=\"15.45%\"\u003ePDI\u003c\/th\u003e\n\u003cth width=\"15.45%\"\u003eStock info\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM0511A5\u003c\/td\u003e\n\u003ctd\u003e25,000\u003c\/td\u003e\n\u003ctd\u003e12,500\u003c\/td\u003e\n\u003ctd\u003e2.0\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM0511A6\u003c\/td\u003e\n\u003ctd\u003e13,000\u003c\/td\u003e\n\u003ctd\u003e8,667\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM0511A7\u003c\/td\u003e\n\u003ctd\u003e30 kDa\u003c\/td\u003e\n\u003ctd\u003e12.5 kDa\u003c\/td\u003e\n\u003ctd\u003e2.4\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM0511A8\u003c\/td\u003e\n\u003ctd\u003e56 kDa\u003c\/td\u003e\n\u003ctd\u003e19.5 kDa\u003c\/td\u003e\n\u003ctd\u003e2.87\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM0511A9\u003c\/td\u003e\n\u003ctd\u003e11 kDa\u003c\/td\u003e\n\u003ctd\u003e6.9 kDa\u003c\/td\u003e\n\u003ctd\u003e1.60\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM0511A12\u003c\/td\u003e\n\u003ctd\u003e30 kDa\u003c\/td\u003e\n\u003ctd\u003e15.7 kDa\u003c\/td\u003e\n\u003ctd\u003e1.91\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM0511A13\u003c\/td\u003e\n\u003ctd\u003e27 kDa\u003c\/td\u003e\n\u003ctd\u003e18 kDa\u003c\/td\u003e\n\u003ctd\u003e1.50\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbutton class=\"anchor expand-link\" data-expand-target=\"past product detail\" data-toggle-text=\"Hide past product detail\" type=\"button\"\u003ePast product details\u003c\/button\u003e\u003c\/p\u003e\n\u003ch2 id=\"literature\"\u003eLiterature and Reviews\u003c\/h2\u003e\n\u003chr\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cem\u003eEfficient inorganic–organic hybrid heterojunction solar cells containing perovskite compound and polymeric hole conductors,\u003c\/em\u003e J. Heo et al., Nat. Photonics 7, 486–491 (2013) doi:10.1038\/nphoton.2013.80.\u003c\/li\u003e\n\u003cli\u003eC\u003cem\u003eompositional engineering of perovskite materials for high-performance solar cells,\u003c\/em\u003e N. Jeon et al., Nature 517, 476–480 (2015), doi:10.1038\/nature14133.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eHigh-performance photovoltaic perovskite layers fabricated through intramolecular exchange, \u003c\/em\u003eW-S. Yang et al., Science, 348 (6240), 1234-1237 (2015). DOI: 10.1126\/science.aaa9272.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cdiv class=\"expandable\" id=\"literature-and-reviews\"\u003e\n\u003col start=\"4\"\u003e\n\u003cli\u003e\n\u003cem\u003eHigh-efficient solid-state perovskite solar cells without lithium salt in the hole transport material,\u003c\/em\u003e NANO 09, 1440001 (2014). DOI: 10.1142\/S1793292014400013.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eChemical Management for Colorful, Efficient, and Stable Inorganic−Organic Hybrid Nanostructured Solar Cells,\u003c\/em\u003e J. Noh et al., Nano Lett., 13, 1764−1769 (2013), dx.doi.org\/10.1021\/nl400349b.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eAchieving a stable time response in polymeric radiation sensors under charge injection by X-rays, \u003c\/em\u003eA. Intaniwet et al., ACS Appl Mater Interfaces. 2(6), 1692-9 (2010). doi: 10.1021\/am100220y.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eEnhanced Charge Separation in Ternary P3HT\/PCBM\/CuInS2 Nanocrystals Hybrid Solar Cells, \u003c\/em\u003eA. Lefrançois et al., Sci Rep. 2015; 5: 7768. doi: 10.1038\/srep07768.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eDopant-Free Spiro-Triphenylamine\/Fluorene as Hole-Transporting Material for Perovskite Solar Cells with Enhanced Efficiency and Stability,\u003c\/em\u003e Y. Wang et al., Adv. Funct. Mater., 26, 1375–1381 (2016); DOI: 10.1002\/adfm.201504245.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eMultiply charged conjugated polyelectrolytes as a multifunctional interlayer for efficient and scalable perovskite solar cells\u003c\/em\u003eJung, E.D. et al. Advanced Materials, 32(30). (2020). doi: 10.1002\/adma.202002333.\u003c\/li\u003e\n\u003cli\u003eLi, Z. et al. (2022b) 'Organometallic-functionalized interfaces for highly efficient inverted perovskite solar cells,' Science, 376(6591), pp. 416–420. https:\/\/doi.org\/10.1126\/science.abm8566.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbutton class=\"anchor expand-link\" data-expand-target=\"literature-and-reviews\" data-toggle-text=\"Hide Literature and Reviews\" type=\"button\"\u003eView Literature and Reviews\u003c\/button\u003e\u003c\/p\u003e","brand":"Ossila","offers":[{"title":"M0511A10 Mw 12.6 kDa PDI 2.29 \/ 100 mg","offer_id":51522338685144,"sku":"M0511A10-100mg","price":250.0,"currency_code":"GBP","in_stock":true},{"title":"M0511A10 Mw 12.6 kDa PDI 2.29 \/ 250 mg","offer_id":51522338717912,"sku":"M0511A10-250mg","price":500.0,"currency_code":"GBP","in_stock":true},{"title":"M0511A10 Mw 12.6 kDa PDI 2.29 \/ 500 mg","offer_id":51522338750680,"sku":"M0511A10-500mg","price":900.0,"currency_code":"GBP","in_stock":true},{"title":"M0511A10 Mw 12.6 kDa PDI 2.29 \/ 1 g","offer_id":51522338783448,"sku":"M0511A10-1g","price":1500.0,"currency_code":"GBP","in_stock":true},{"title":"M0511A14 Mw 10.7 kDa PDI 1.29 \/ 100 mg","offer_id":51346645713112,"sku":"M0511A14-100mg","price":250.0,"currency_code":"GBP","in_stock":true},{"title":"M0511A14 Mw 10.7 kDa PDI 1.29 \/ 250 mg","offer_id":51346645745880,"sku":"M0511A14-250mg","price":500.0,"currency_code":"GBP","in_stock":true},{"title":"M0511A14 Mw 10.7 kDa PDI 1.29 \/ 500 mg","offer_id":51346645778648,"sku":"M0511A14-500mg","price":900.0,"currency_code":"GBP","in_stock":true},{"title":"M0511A14 Mw 10.7 kDa PDI 1.29 \/ 1 g","offer_id":51346645811416,"sku":"M0511A14-1g","price":1500.0,"currency_code":"GBP","in_stock":true},{"title":"M0511A15 Mw 45.0 kDa PDI 1.82 \/ 100 mg","offer_id":51584462618840,"sku":"M0511A15-100mg","price":250.0,"currency_code":"GBP","in_stock":true},{"title":"M0511A15 Mw 45.0 kDa PDI 1.82 \/ 250 mg","offer_id":51584462651608,"sku":"M0511A15-250mg","price":500.0,"currency_code":"GBP","in_stock":true},{"title":"M0511A15 Mw 45.0 kDa PDI 1.82 \/ 500 mg","offer_id":51584462684376,"sku":"M0511A15-500mg","price":900.0,"currency_code":"GBP","in_stock":true},{"title":"M0511A15 Mw 45.0 kDa PDI 1.82 \/ 1 g","offer_id":51584462717144,"sku":"M0511A15-1g","price":1500.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/ptaa-structure.png?v=1736773782"},{"product_id":"four-point-probe-system","title":"Four-Point Probe","description":"\u003ch2 id=\"product-oneliner\"\u003eQuick, Easy \u0026amp; Reliable Sheet Resistance Measurements\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003ePrecision system with interchangeable probes to adapt to your samples\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#software\"\u003eSoftware\u003c\/a\u003e | \u003ca href=\"#included\"\u003eIn the Box\u003c\/a\u003e | \u003ca href=\"#accessories\"\u003eRelated Products\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eAccurately measure sheet resistance, resistivity, and conductivity of thin films in seconds using the Ossila Four-Point Probe. With two probe types available, you can get the most out of your four-point probe station:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSoft-tipped probes are suitable for delicate samples such as organic materials or very thin films. The spring-loaded, rounded contacts take high quality surface measurements without damaging your sample.\u003c\/li\u003e\n\u003cli\u003eSharp-tipped probes are designed to pierce insulating oxide layers for reliable measurement of hard materials like silicon.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith an in-built display for quick measurements, The Four-Point Probe Plus can provide sheet resistance and conductivity measurements at the touch of a button without connecting to a PC. This is ideal for use inside a glove box. Both models can also be PC controlled with free downloadable software. Choose the four-point probe for rapid and reliable material characterization.\u003c\/p\u003e\n\u003cdiv class=\"info-tip-box\"\u003e\n\u003ch5\u003eMay 2026 Firmware Update\u003c\/h5\u003e\n\u003cp\u003eVersion 1.1.1 of the Four-Point Probe Plus built-in control firmware is now available. This update enables the full 20 μΩ range. We recommend updating at your earliest convenience. For step-by-step instructions, refer to section 7.2.5 of the user manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Wide_resistance_Range.svg?v=1697197697\" loading=\"lazy\" height=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eCharacterize a Wide\u003cbr\u003eRange of Materials\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eMeasure sheet resistances\u003cbr\u003efrom 100 mΩ\/sq to 10 MΩ\/sq\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Voltage.svg?v=1697197768\" loading=\"lazy\" height=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eWide Current and Voltage Range\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eCurrents from 1 μA to 200 mA, voltages from 100 μV to 10 V\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon_non_destructive_testing_alt.svg\" loading=\"lazy\" height=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eRound, Spring-Loaded Probes\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eUniform force of 60 grams protects delicate samples\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Surface_Cleaning.svg?v=1718707947\" loading=\"lazy\" height=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eSharp Nickel-Plated\u003cbr\u003eTungsten Carbide Probes\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003ePierce insulating layers with\u003cbr\u003ea maximum force of 197.43 gf\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cimg alt=\"Sheet resistance measurements by NASA\" class=\"float-left no-margin-bottom\" height=\"42\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila_Guarantee_Icons_Clear_Upfront_Pricing.svg\" width=\"38\"\u003e\n\u003cp class=\"no-margin\"\u003eTowards more durable spacecraft: \u003ca href=\"https:\/\/ntrs.nasa.gov\/api\/citations\/20240002413\/downloads\/TM-20240002413.pdf\" rel=\"nofollow\" target=\"_blank\"\u003eNASA\u003c\/a\u003e used the Ossila Four-Point Probe to investigate the effects of space exposure on indium tin oxide coatings through sheet resistance measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure\u003e\u003cvideo width=\"848.328\" title=\"Four Point Probe. Product Overview video\" preload=\"none\" poster=\"https:\/\/cdn.ossila.com\/videos\/Four-Point-Probe-Product-Overview.jpg\" height=\"477.172\" crossorigin=\"\" controlslist=\"nodownload\" controls=\"controls\" class=\"widescreen\"\u003e\n    \u003csource type=\"video\/mp4\" src=\"https:\/\/cdn.ossila.com\/videos\/four-point-probe-product-overview.mp4\"\u003e\n    \u003ctrack srclang=\"en\" src=\"https:\/\/cdn.ossila.com\/videos\/four-point-probe-product-overview.vtt\" label=\"English\" kind=\"subtitles\" default=\"\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"Four Point Probe Product Overview\",\n\"description\": \"Four Point Probe Product Overview\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/Four-Point-Probe-Product-Overview.jpg\",\n\"uploadDate\": \"2023-04-19\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/four-point-probe-product-overview.mp4\",\n\"duration\": \"PT0M55S\"\n}\n\u003c\/script\u003e\u003c\/figure\u003e\n\u003ch2 id=\"specification\"\u003eKey Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eApplied Voltage Range\u003c\/th\u003e\n\u003ctd\u003e±10 mV – ±10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eVoltage Measurement Precision\u003c\/th\u003e\n\u003ctd\u003e±333 μV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCurrent Measurement Ranges\u003c\/th\u003e\n\u003ctd\u003e±20 μA – ±200 mA (5 ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSheet Resistance Range\u003c\/th\u003e\n\u003ctd\u003e100 mΩ\/sq – 10 MΩ\/sq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor more information on the current ranges, see our \u003ca href=\"https:\/\/www.ossila.com\/products\/xtralien-source-measure-unit-source-meter#specification\"\u003eSMU specifications.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eProbe Types\u003c\/h3\u003e\n\u003cp\u003eThe soft-tipped probes reduce the potential of damaging delicate thin films with rounded tips and a larger surface area with a radius of 0.24 mm. The gold-plated probes are mounted on springs to allow them to retract into the probe head when making contact with the sample. This design spreads out the downward force and ensures that a uniform force of 60 grams is applied to the sample. The soft-tipped probes are not suitable for silicon or other materials which naturally form insulating oxide layers.\u003c\/p\u003e\n\u003cp\u003eThe sharped-tipped probes are designed for materials with naturally forming oxide layers, with a tip diameter of 0.08 mm. The sharp tipped probes are capable of piercing through oxide layers, directly contacting materials like silicon. The nickel-plated tungsten carbide probes can apply a maximum force of 197.43 gf to pierce the insulating layer for reliable sample measurements.\u003c\/p\u003e\n\u003cfigure class=\"double-float-left\"\u003e\u003cimg alt=\"Schematic diagram of the probes of the Four-Point Probe Head\" height=\"265\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Four-Point_Probe_Head.svg?v\" width=\"373\"\u003e\n\u003cfigcaption\u003eSoft-tipped probes\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cfigure class=\"double-float-right\"\u003e\u003cimg alt=\"Schematic diagram of the probes of the Four-Point Probe Head\" height=\"265\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/four-point-probe-soft-tipped-head.svg?v=1682412884\" width=\"373\"\u003e\n\u003cfigcaption\u003eSharp-tipped probes\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp class=\"text-muted\"\u003ePlease note: Your Ossila Four-Point Probe will require \u003cspan data-olk-copy-source=\"MessageBody\"\u003escreen firmware version 1.1.0 or newer to use\u003c\/span\u003e the sharp-tipped probe head. You can \u003ca href=\"https:\/\/www.ossila.com\/pages\/software-drivers#Firmware-Updater\"\u003edownload the latest firmware\u003c\/a\u003e from our website.\u003c\/p\u003e\n\u003cp class=\"text-muted\"\u003eThe gold plating on the soft-tipped probes can degrade in certain conditions, such as when used in humid environments, or with samples that are corrosive, abbrasive, acidic, etc, especially under electrical load. Gold can also diffuse into certain materials such as copper, aluminium, tin and silicon, especially at high temperatures (which can occur due to resistive heating at high current).\u003c\/p\u003e\n\u003cp class=\"text-muted\"\u003eIf you need a replacement probe head for the T2001A3 model, please \u003ca href=\"\/pages\/contact-us\"\u003econtact us\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eSheet Resistance\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eSheet Resistance\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eSMU Accuracy*\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003ePrecision\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eMeasured at Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e100 mΩ\/sq\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±8%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±3%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e1 Ω\/sq\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±2%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±0.5%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e10 Ω\/sq\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±1%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±0.5%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e100 Ω\/sq\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±1%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e1 kΩ\/sq\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±1%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e10 kΩ\/sq\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±1%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±0.02%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e2000 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e100 kΩ\/sq\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±2%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e200 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e1 MΩ\/sq\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±8%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±0.5%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e20 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e10 MΩ\/sq\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±30%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±5%\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e20 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"text-muted\"\u003e*The probe head can introduce up to 4% additional measurement error.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#specifications-continued\"\u003eSee more specifications\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eReliably Measure Samples\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Surface_Cleaning.svg?v=1717677129\" loading=\"lazy\" height=\"112\" alt=\"Soft- or sharp-tipped probes\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eChoose Your Probe Tips\u003c\/p\u003e\n\u003cp\u003eEasily switch between soft- or sharp-tipped probe heads depending on your sample type. Soft-tipped probes spread the downward force, and are perfect for measuring delicate thin or organic samples. The sharp-tipped probes can apply a higher maximum force to pierce through insulating oxide layers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Simple_to_use_Software.svg?v=1697547419\" loading=\"lazy\" height=\"112\" alt=\"Simple to Use Interface\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eQuick Measurements\u003c\/p\u003e\n\u003cp\u003eWith the plus model, take measurements from your lab bench without connecting to a PC—simply load your sample and press go. Inputting sample dimensions allows you to measure conductivity and resistivity while you can also get real-time data of current and voltage between the outer pins and the voltage between the inner pins.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Accuracy.svg?v=1697194989\" loading=\"lazy\" height=\"112\" alt=\"High accuracy four-point probe\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eDesigned for High Accuracy\u003c\/p\u003e\n\u003cp\u003eWith features that prioritise the accuracy of your measurements, eliminate voltage offsets with positive and negative polarity measurements; rely less on correction factors by characterizing larger samples; and achieve good electrical contact each time with the micrometer height control and non-slip stage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eFour-Point Probe Gallery*\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca title=\"Four-Point Probe with Inbuilt Data Display\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/four-point-probe.jpg?width=1620\"\u003e \u003cimg alt=\"Four-Point Probe with Inbuilt Data Display\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/four-point-probe.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca title=\"Four-Point Probe without display\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-Four-Point-Probe.jpg?width=1620\"\u003e \u003cimg alt=\"Four-Point Probe without display\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-Four-Point-Probe.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca title=\"Inbuilt Data Display\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/four-point-probe-screen.jpg?width=1620\"\u003e \u003cimg alt=\"Inbuilt Data Display\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/four-point-probe-screen.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca title=\"Soft Contact Probes\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/four-point-probe-reflection.jpg?width=1620\"\u003e \u003cimg alt=\"Soft Contact Probe\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/four-point-probe-reflection.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/four-point-probe-sharp-probe-head.jpg\" class=\"carousel-item\" title=\"Four Point Prob Sharp Probe Head\"\u003e \u003cimg width=\"420\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/four-point-probe-sharp-probe-head.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" alt=\"Four Point Prob Sharp Probe Head\"\u003e \u003c\/a\u003e \u003ca title=\"Micrometer Height Control\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/four-point-probe-set-up.jpg?width=1620\"\u003e \u003cimg alt=\"Micrometer Height Control\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/four-point-probe-set-up.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca role=\"button\" class=\"carousel-left-control\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-left\"\u003e\n      \u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\n    \u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious \u003c\/span\u003e\u003c\/a\u003e \u003ca role=\"button\" class=\"carousel-right-control\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-right\"\u003e\n      \u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\n    \u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext \u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp class=\"text-muted\"\u003e*Photos include both Original and Plus models\u003c\/p\u003e\n\u003ch2 id=\"software\"\u003eSoftware\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eYour four-point probe can be controlled using a PC, running our free, user-friendly Ossila Sheet Resistance Lite software. With the Plus model, you can also use the embedded software on the inbuilt data display. Both pieces of software can calculate appropriate geometrical correction factors for the sample geometry and the resistivity and conductivity of the sample to allow for extensive, accurate electrical characterization of materials (if you would like to record your data, you will need to use the Ossila Sheet Resistance Lite software).\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg width=\"848\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-sheet-resistance-lite-pc-software.png?width=848\u0026amp;height=192\" loading=\"lazy\" height=\"192\" alt=\"Sheet Resistance Lite Software\"\u003e\n\u003cfigcaption\u003eSheet Resistance Lite Measurement Software\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe Sheet Resistance Lite software is supplied on the included USB memory stick along with a copy of the user manual and QC data. In addition, the latest version is always available to download for free from our website.\u003c\/p\u003e\n\u003cp\u003eThe Sheet Resistance Lite software saves data to comma-separated value (.csv) files, facilitating importing the data into your preferred analysis software. Advanced settings give you greater control over the measurment, allowing you to set voltage and current limits, perform negative polarity measurements, or use probes with different spacings.\u003c\/p\u003e\n\u003ch3\u003eSheet Resistance Lite Software Requirements\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eOperating System\u003c\/th\u003e\n\u003ctd\u003eWindows 11 (64-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCPU\u003c\/th\u003e\n\u003ctd\u003eDual Core 2 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eRAM\u003c\/th\u003e\n\u003ctd\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAvailable Hard Drive Space\u003c\/th\u003e\n\u003ctd\u003e252 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMonitor Resolution\u003c\/th\u003e\n\u003ctd\u003e1440 x 900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003eUSB 2.0, or Ethernet (requires DHCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cvideo width=\"848.328\" title=\"Four Point Probe Software\" preload=\"none\" poster=\"https:\/\/cdn.ossila.com\/videos\/four-point-probe-software-video.jpg\" height=\"477.172\" crossorigin=\"\" controlslist=\"nodownload\" controls=\"controls\" class=\"widescreen\"\u003e\n    \u003csource type=\"video\/mp4\" src=\"https:\/\/cdn.ossila.com\/videos\/four-point-probe-software-video.mp4\"\u003e\n    \u003ctrack default=\"\" kind=\"subtitles\" label=\"English\" src=\"https:\/\/cdn.ossila.com\/videos\/four-point-probe-software-video.vtt\" srclang=\"en\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"Four Point Probe Software\",\n\"description\": \"Four Point Probe Software\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/four-point-probe-software-video.jpg\",\n\"uploadDate\": \"2025-10-24\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/four-point-probe-software-video.mp4\",\n\"duration\": \"PT1M19S\"\n}\n\u003c\/script\u003e\u003c\/p\u003e\n\u003ch2 id=\"specifications-continued\"\u003eAdditional Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure\u003e\u003cimg height=\"385\" width=\"890\" loading=\"lazy\" alt=\"Ossila Four-Point Probe with Inbuilt Data Display wireframe diagram\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/four-point-probe-plus-display-wireframe.svg\"\u003e\u003c\/figure\u003e\n\u003ch3\u003ePhysical Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFour-Point Probe Dimensions (W x H x D)\u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003e145 mm x 150 mm x 240 mm (5.71\" x 5.91\" x 9.45\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003e\u003cbr\u003e\u003c\/th\u003e\n\u003cth\u003eSoft-tipped probes\u003c\/th\u003e\n\u003cth\u003eSharp-tipped probes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eProbe Spacing\u003c\/th\u003e\n\u003ctd\u003e1.27 mm (0.05\")\u003c\/td\u003e\n\u003ctd\u003e1.6 mm (0.063\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eRectangular Sample Size Range\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eLong edge minimum: 5 mm (0.20\")\u003c\/p\u003e\n\u003cp class=\"no-margin\"\u003eShort edge maximum: 152.4 mm (6\")\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"38.2%\"\u003e\n\u003cp\u003eLong edge minimum: 6 mm (0.24\")\u003c\/p\u003e\n\u003cp class=\"no-margin\"\u003eShort edge maximum: 152.4 mm (6\")\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCircular Sample Size Range (Diameter)\u003c\/th\u003e\n\u003ctd\u003e5 mm – 152.4 mm (0.20\" – 6.00\")\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6 mm – 152.4 mm (0.24\" – 6.00\")\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Sample Thickness\u003c\/th\u003e\n\u003ctd\u003e8 mm (0.31\")\u003c\/td\u003e\n\u003ctd\u003e5 mm (0.2\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eResistivity and Conductivity Range\u003c\/h3\u003e\n\u003cp\u003eAs the system measures the sheet resistance of a sample, a general range of measurable resistivities or conductivities cannot be given. This is because the measurable resistivity range depends on the thickness of the sample being tested. The resistivity of a sample can be calculated from its sheet resistance and thickness using the following equation:\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg height=\"21\" width=\"86\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/sheet-resistance-resistivity-equation.png?v=1518786886\" alt=\"Sheet resistance resistivity equation\" loading=\"lazy\"\u003e\u003c\/figure\u003e\n\u003cp\u003eThe system is capable of measuring between 100 mΩ\/sq and 10 MΩ\/sq, so if we use these values in the formula above with a sample 50 nm thick, then the resistivity (conductivity) range that can be measured by the system will be 5 nΩ.m to 500 mΩ.m (2 S\/m to 200 MS\/m). If the sample is 400 µm thick, then the resistivity (conductivity) range of the system is 40 µΩ.m to 4 kΩ.m (250 µS\/m to 25 kS\/m). Below is a table of the resistivity and conductivity ranges of the system for samples with thicknesses of different orders of magnitude:\u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 137.157px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 29.5193%; height: 19.5938px;\" class=\"text-center\"\u003eCoating Thickness\u003c\/th\u003e\n\u003cth style=\"width: 32.1995%; height: 19.5938px;\" class=\"text-center\"\u003eResistivity Range\u003c\/th\u003e\n\u003cth style=\"width: 34.2666%; height: 19.5938px;\" class=\"text-center\"\u003eConductivity Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.5193%; height: 19.5938px;\" class=\"text-center\"\u003e10 nm\u003c\/td\u003e\n\u003ctd style=\"width: 32.1995%; height: 19.5938px;\" class=\"text-center\"\u003e1 nΩ.m – 100 mΩ.m\u003c\/td\u003e\n\u003ctd style=\"width: 34.2666%; height: 19.5938px;\" class=\"text-center\"\u003e10 S\/m – 1 GS\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.5193%; height: 19.5938px;\" class=\"text-center\"\u003e100 nm\u003c\/td\u003e\n\u003ctd style=\"width: 32.1995%; height: 19.5938px;\" class=\"text-center\"\u003e10 nΩ.m – 1 Ω.m\u003c\/td\u003e\n\u003ctd style=\"width: 34.2666%; height: 19.5938px;\" class=\"text-center\"\u003e1 S\/m – 100 MS\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.5193%; height: 19.5938px;\" class=\"text-center\"\u003e1 µm\u003c\/td\u003e\n\u003ctd style=\"width: 32.1995%; height: 19.5938px;\" class=\"text-center\"\u003e100 nΩ.m – 10 Ω.m\u003c\/td\u003e\n\u003ctd style=\"width: 34.2666%; height: 19.5938px;\" class=\"text-center\"\u003e100 mS\/m – 10 MS\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.5193%; height: 19.5938px;\" class=\"text-center\"\u003e10 µm\u003c\/td\u003e\n\u003ctd style=\"width: 32.1995%; height: 19.5938px;\" class=\"text-center\"\u003e1 µΩ.m – 100 Ω.m\u003c\/td\u003e\n\u003ctd style=\"width: 34.2666%; height: 19.5938px;\" class=\"text-center\"\u003e10 mS\/m – 1 MS\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.5193%; height: 19.5938px;\" class=\"text-center\"\u003e100 µm\u003c\/td\u003e\n\u003ctd style=\"width: 32.1995%; height: 19.5938px;\" class=\"text-center\"\u003e10 µΩ.m – 1 kΩ.m\u003c\/td\u003e\n\u003ctd style=\"width: 34.2666%; height: 19.5938px;\" class=\"text-center\"\u003e1 mS\/m – 100 kS\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.5193%; height: 19.5938px;\" class=\"text-center\"\u003e1 mm\u003c\/td\u003e\n\u003ctd style=\"width: 32.1995%; height: 19.5938px;\" class=\"text-center\"\u003e100 µΩ.m – 10 kΩ.m\u003c\/td\u003e\n\u003ctd style=\"width: 34.2666%; height: 19.5938px;\" class=\"text-center\"\u003e100 µS\/m – 10 kS\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"included\"\u003eIn the Box\u003c\/h2\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eOssila Four-Point Probe with head(s) and stage\u003c\/li\u003e\n\u003cli\u003eIntegrated source measure unit\u003c\/li\u003e\n\u003cli\u003eInbuilt data display with sheet resistance measurement capability (T2001A5 only)\u003c\/li\u003e\n\u003cli\u003e60 x 60 mm (2.36\" x 2.36\") glass substrate coated with 400 – 450 nm of FTO\u003c\/li\u003e\n\u003cli\u003e10kΩ resistor test head\u003c\/li\u003e\n\u003cli\u003ePower adapter (24 VDC)\u003c\/li\u003e\n\u003cli\u003eUSB Driver with QC test report \u0026amp; QC test data\u003c\/li\u003e\n\u003cli\u003eUSB-B cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"accessories\"\u003eAccessories and Related Products\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e[[collection handle=\"substrates-and-fabrication\" tags=\"substrate\" limit=\"4\"]]\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/four-point-probe-features\"\u003e\u003cimg src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Four-Point-Probe-Substrate-Close-Up.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\" loading=\"lazy\" height=\"160\" alt=\"What Four Point Probe Features Do You Need?\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.ossila.com\/pages\/four-point-probe-features\"\u003e What Four-Point Probe Features Do You Need?\u003c\/a\u003e\n\u003cp\u003eBuilding on the reliable source measure unit, the Ossila Four-Point Probe is an instrument that makes measuring sheet resistance as straightforward as possible for users. Without complex calibration or set up, you just put your thin film into the four-point probe station and immediately get reliable sheet resistance, conductivity and resistivity values for your thin films.\u003c\/p\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/four-point-probe-features\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Plus (New!) \/ Soft-tipped probe head","offer_id":49564303360216,"sku":"T2001A5","price":2100.0,"currency_code":"GBP","in_stock":true},{"title":"Plus (New!) \/ Sharp-tipped probe head","offer_id":50608355639512,"sku":"T2001B5","price":2400.0,"currency_code":"GBP","in_stock":true},{"title":"Plus (New!) \/ Both (1 x Soft-tipped probe head \u0026 1 x Sharp-tipped probe head)","offer_id":50608355672280,"sku":"T2001A5-P2010B1","price":2500.0,"currency_code":"GBP","in_stock":true},{"title":"Original \/ Soft-tipped probe head","offer_id":49564303392984,"sku":"T2001A4","price":1700.0,"currency_code":"GBP","in_stock":true},{"title":"Original \/ Sharp-tipped probe head","offer_id":50608355705048,"sku":"T2001B4","price":2000.0,"currency_code":"GBP","in_stock":true},{"title":"Original \/ Both (1 x Soft-tipped probe head \u0026 1 x Sharp-tipped probe head)","offer_id":50608355737816,"sku":"T2001A4-P2010B1","price":2100.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/Four-Point-Probe-Focus-Stack-Product-Image.jpg?v=1751283470"},{"product_id":"contact-angle-goniometer","title":"Contact Angle Goniometer","description":"\u003ch2 id=\"product-oneliner\"\u003eRapid Measurements with Easy, Accurate Analysis\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eOptimize inks and coatings efficiently with HD recording and intuitive PC software\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#software\"\u003eSoftware\u003c\/a\u003e | \u003ca href=\"#included\"\u003eIn the Box\u003c\/a\u003e | \u003ca href=\"#accessories\"\u003eAccessories\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eOptimize inks and coatings efficiently with fast, reliable, and easy contact angle and surface tension measurement of liquid droplets. The Ossila Contact Angle Goniometer brings intuitive PC software, high quality video, and rapid image capture to your lab. Use the software to characterize high contact angles for water resistant or protective coatings, or low contact angles for highly uniform solution coatings.\u003c\/p\u003e\n\u003cp\u003eThanks to the low price and compact size, the Ossila Contact Angle Goniometer is a great choice for any characterization setup.\u003c\/p\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Two-Year Warranty\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Glove_Box_key_Features__Two_year_warranty.svg?v=1718707947\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eTwo-Year Warranty\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eBuy with confidence\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Free software\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon-Free-Software-Update.svg?v=1697197697\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eFree Software\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003ePlus future updates\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Compact contact angle goniometer\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon-Compact.svg?v=1718795142\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eCompact Design\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eSmall lab footprint\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Easy to use\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Easy_To_Use.svg?v=1697194957\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eEasy to Use\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eSimple and intuitive\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Easier Ink Optimisation\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Easier_Ink_Optimisation.svg?v=1697201968\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eEasy Ink Optimization\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eContinuous feedback\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Rapid Image Capture\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Rapid_Image_Capture.svg?v=1697203017\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eRapid Image Capture\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eStudy the wetting process\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"High-Resolution Video\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_High_Res_Video.svg?v=1697202095\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eHigh-Resolution Video\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eCapture quality videos of your droplets\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Affordable\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Low_Cost.svg?v=1697194884\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eGreat Value\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eAffordable without compromising on quality\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure\u003e\u003cvideo class=\"widescreen\" controls=\"controls\" controlslist=\"nodownload\" crossorigin=\"\" height=\"477.172\" poster=\"https:\/\/cdn.ossila.com\/videos\/contact-angle-goniometer-product-overview.jpg\" preload=\"none\" title=\"Contact Angle Goniometer Product Overview video\" width=\"848.328\"\u003e\n        \u003csource src=\"https:\/\/cdn.ossila.com\/videos\/contact-angle-goniometer-product-overview-1080p.mp4\" type=\"video\/mp4\"\u003e\n        \u003ctrack default=\"\" kind=\"subtitles\" label=\"English\" src=\"https:\/\/cdn.ossila.com\/videos\/contact-angle-goniometer-product-overview.vtt\" srclang=\"en\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"Contact Angle Goniometer Product Overview\",\n\"description\": \"Ossila Contact Angle Goniometer Product Overview\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/contact-angle-goniometer-product-overview.jpg\",\n\"uploadDate\": \"2023-11-29\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/contact-angle-goniometer-product-overview-1080p.mp4\",\n\"duration\": \"PT1M09S\"\n}\n\u003c\/script\u003e\u003c\/figure\u003e\n\u003ch2 id=\"specification\"\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 38.0937%;\" width=\"38.2%\"\u003eMeasurement Accuracy\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%;\"\u003e±1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 38.0937%;\" width=\"38.2%\"\u003eMeasurement Range\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%;\"\u003e5° – 180°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 38.0937%;\" width=\"38.2%\"\u003eOverall Product Dimensions (W x H x D)\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%;\"\u003e320 mm x 95 mm x 165 mm (12.60\" x 3.75\" x 6.50\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 38.0937%;\" width=\"38.2%\"\u003eStage Area\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%;\"\u003e50 mm x 50 mm (1.97\" x 1.97\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 38.0937%;\" width=\"38.2%\"\u003eMaximum Sample Thickness\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%;\"\u003e20 mm (0.79\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 38.0937%;\" width=\"38.2%\"\u003eMaximum Camera Resolution\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%;\"\u003e1920 x 1080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; text-align: left;\"\u003e\u003cstrong\u003eSensor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50%; text-align: left;\"\u003e1\/2.7 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; text-align: left;\"\u003e\u003cstrong\u003ePixel Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50%; text-align: left;\"\u003e3 μm x 3 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; text-align: left;\"\u003e\u003cstrong\u003eImage Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50%; text-align: left;\"\u003e5856 μm x 3276 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg alt=\"Ossila Contact Angle Goniometer wireframe diagram\" height=\"438.75\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Product_Wireframes_Contact-Angle-Goniometer.svg?v=1709633899\" width=\"636\"\u003e\n\u003cfigcaption\u003eOssila Contact Angle Goniometer wireframe\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSyringe Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSyringe Volume\u003c\/th\u003e\n\u003ctd\u003e25 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eNeedle Gauge\u003c\/th\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eNeedle Outer Diameter\u003c\/th\u003e\n\u003ctd\u003e0.72 mm (0.028\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eNeedle Inner Diameter\u003c\/th\u003e\n\u003ctd\u003e0.37 mm (0.015\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eNeedle Length\u003c\/th\u003e\n\u003ctd\u003e51 mm (2.01\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eTip Shape\u003c\/th\u003e\n\u003ctd\u003eBlunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"features\"\u003eContact Angle Goniometer Features\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"High-Resolution camera\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-camera-square.jpg?width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eHigh-Resolution Camera\u003c\/p\u003e\n\u003cp\u003eTake quality videos and images of your droplets. A high-resolution 1920 x 1080 camera captures up to 30 frames per second, while the manual focusing lens gives you complete control over image sharpness. If file size is a concern, you can set a lower resolution or frame rate when exporting to save space on your hard drive.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"Monochromatic light source\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-light-source-square.jpg?width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eLight Source for Accurate Edge Detection\u003c\/p\u003e\n\u003cp\u003eThe powerful, mains-powered monochromatic backlight helps the software to accurately detect the edges of the droplet using a Canny edge detection algorithm. The bright, uniform rectangular panel creates a larger change in pixel lightness than would otherwise occur, which ensures that a sharp edge can be found.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"Syringe clamping mechanism\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-syringe-clamping-mechanism-square.jpg?width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eSyringe Clamping Mechanism\u003c\/p\u003e\n\u003cp\u003eThe versatile and adaptable clamp system can be used to secure a wide range of droplet dispensing equipment. Included with the Ossila Contact Angle Goniometer system is a 25µl glass syringe with a removable blunt tip needle, which is ideal for dispensing droplets for both contact angle and surface tension measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"Adjustable sample stage\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-sample-stage-square.jpg?width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eAdjustable Sample Stage\u003c\/p\u003e\n\u003cp\u003eObtain a level surface and prevent the droplet from moving during deposition. Lower and raise the stage without affecting the level so you can add or remove substrates and then position the platform as close to the needle as possible. The fine level of adjustment even lets you set a slight tilt towards the camera to help align the baseline.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eContact Angle Goniometer Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-level.jpg?width=1620\" title=\"Contact Angle Goniometer\"\u003e \u003cimg alt=\"Contact Angle Goniometer\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-level.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-close-up.jpg?width=1620\" title=\"Contact Angle Goniometer Drop\"\u003e \u003cimg alt=\"Contact Angle Goniometer Drop\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-close-up.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-camera-view.jpg?width=1620\" title=\"Contact Angle Goniometer Camera\"\u003e \u003cimg alt=\"Contact Angle Goniometer Camera\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-camera-view.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-in-use.jpg?width=1620\" title=\"Contact Angle Goniometer in use\"\u003e \u003cimg alt=\"Contact Angle Goniometer in use\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-in-use.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-drop.jpg?width=1620\" title=\"Contact Angle Goniometer droplet\"\u003e \u003cimg alt=\"Contact Angle Goniometer droplet\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-drop.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca class=\"carousel-left-control\" role=\"button\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-left\"\u003e\n            \u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\n        \u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious\u003c\/span\u003e \u003c\/a\u003e \u003ca class=\"carousel-right-control\" role=\"button\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-right\"\u003e\n            \u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\n        \u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003ch2 style=\"margin-top: 10px;\"\u003eTestimonials\u003c\/h2\u003e\n\u003chr\u003e\n\u003cblockquote class=\"marks\"\u003eI use a Contact Angle Goniometer and Spin Coater from Ossila, the best tools I have ever used for the application of Perovskite solar cells. I plan to order more devices from the same brand.\u003c\/blockquote\u003e\n\u003cp class=\"text-right\"\u003eAshique Kotta, Jeonbuk National University\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"software\"\u003eSoftware\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eThe Contact Angle Goniometer comes complete with user-friendly measurement software. This software has been designed to be as intuitive as possible, but we also provide guides on how to use it effectively. The software has two main interactive sections: recording and analysis.\u003c\/p\u003e\n\u003cp\u003eThe Ossila Contact Angle software is included on the supplied USB memory stick, and the latest version is always available to download for free from our website.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"contact angle and surface tension measurement technique\" height=\"288.409\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Surface-Tension-Measurement-01.svg?v=1709803875\" width=\"848.328\"\u003e\n\u003cfigcaption\u003eContact Angle and Surface Tension Measurement Techniques\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRecording\u003c\/h3\u003e\n\u003cp\u003eCapture high-resolution videos in the recording section of the software. The videos will automatically be saved to the destination of your choosing and are saved in .avi file format, which means you can watch them in any common video player or edit them in a video editor. When loaded into the contact angle software, the videos will appear as a series of images which can be analyzed individually.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"Ossila Contact Angle software\" height=\"464\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-software-light-mode.png?width=848\u0026amp;height=464\" width=\"848\"\u003e\n\u003cfigcaption\u003eOssila Contact Angle software\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAnalysis\u003c\/h3\u003e\n\u003cp\u003eMeasure contact angle and surface tension of your recorded droplets in the analysis section of the software. The software performs an edge detection algorithm on the droplet, then uses an appropriate fitting technique to calculate its properties.\u003c\/p\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"Contact Angle\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Easier_Ink_Optimisation.svg?v=1697201968\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eContact Angle\u003c\/p\u003e\n\u003cp\u003eFor droplets with contact angles above 10°, a polynomial curve is fitted to the droplet edge. Where the curve crosses the baseline, its tangent is used to determine the contact angle. If a droplet is below 10°, then a circle fit is used for contact angle measurements instead.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"Surface Tension\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Syring_Compatability.svg?v=1698413426\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eSurface Tension\u003c\/p\u003e\n\u003cp\u003eThe software can also perform optical tensiometry measurements on droplets suspended from a needle tip. A series of droplet models are created using the droplet radius and liquid density. The models are compared with the detected edge and the closest match is used to determine the surface tension of the liquid.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure class=\"padding-top\"\u003e\u003cimg alt=\"Ossila Contact Angle software performing a surface tension measurement\" height=\"477\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-manual-figure_8-12.png?width=848\u0026amp;height=477\" width=\"848\"\u003e\n\u003cfigcaption\u003eOssila Contact Angle software performing a surface tension measurement\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSoftware Requirements\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eOperating System\u003c\/th\u003e\n\u003ctd\u003eWindows 11 (64-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCPU\u003c\/th\u003e\n\u003ctd\u003eQuad Core 2.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eRAM\u003c\/th\u003e\n\u003ctd\u003e8 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAvailable Hard Drive Space\u003c\/th\u003e\n\u003ctd\u003e306 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMonitor Resolution\u003c\/th\u003e\n\u003ctd\u003e1920 x 1080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"included\"\u003eIn the Box\u003c\/h2\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eContact angle goniometer\u003c\/li\u003e\n\u003cli\u003e24 V \/ 2 A DC power adapter\u003c\/li\u003e\n\u003cli\u003eUSB-B cable\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003cli\u003eQC data USB drivers\u003c\/li\u003e\n\u003cli\u003eFront Panel software installer\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e25 µl glass syringe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e10 mm diameter calibration sphere\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"accessories\"\u003eAccessories and Related Products\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e[[collection handle=\"substrates-and-fabrication\" tags=\"substrate\" limit=\"4\" show-more=\"false\"]]\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 button-col\"\u003e\n\u003cdiv class=\"card-box\"\u003e\n\u003ch3 class=\"h4\"\u003eContact Angle Measurements of Surface Wetting\u003c\/h3\u003e\n\u003cp\u003eSurface wetting occurs when a droplet spreads out over a surface, such that its contact angle is below 90°. When the droplet spreads out completely, this angle will be 0°, and 'complete wetting' will have occurred.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact-angle-measurements-surface-wetting\"\u003eLearn more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/getting-started-with-the-ossila-contact-angle-goniometer\"\u003e\u003cimg alt=\"Getting Started with the Ossila Contact Angle Goniometer\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/contact-angle-goniometer-setup-guide.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/getting-started-with-the-ossila-contact-angle-goniometer\"\u003e Getting Started with the Ossila Contact Angle Goniometer\u003c\/a\u003e\n\u003cp\u003eSetting up the Ossila Contact Angle Goniometer is a straightforward process that involves a few simple steps.\u003c\/p\u003e\n\u003ca href=\"\/pages\/getting-started-with-the-ossila-contact-angle-goniometer\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/contact-angle-theory-measurement\"\u003e\u003cimg alt=\"Contact Angle: A Guide to Theory and Measurement\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/page-contact-angle-theory-measurement.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/contact-angle-theory-measurement\"\u003e Contact Angle: A Guide to Theory and Measurement\u003c\/a\u003e\n\u003cp\u003eThis guide will explain what a contact angle is and how it is measured. It will also show you how the Ossila Contact Angle Goniometer works and how to get the best measurement results.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact-angle-theory-measurement\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Default Title","offer_id":2856241430557,"sku":"L2004A1","price":2000.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/contact-angle-featured-image.jpg?v=1754399698"},{"product_id":"dip-coater","title":"Dip Coater","description":"\u003ch2 id=\"product-oneliner\"\u003ePrecision, Programmable Dip Coater for High Quality Films\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eConsistently produce and reproduce high quality films with ease\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources\u003c\/a\u003e | \u003ca href=\"#technical-support\"\u003eTechnical Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eWith high performance specifications and simple-to-use integrated software, the Ossila Dip Coater gives you the tools to coat high quality films at an affordable price. The high precision stage and motor help you consistently and easily achieve a range of coating thicknesses. Designed by experienced materials scientists, the Ossila Dip Coater improves your workflow with a quick-release clamp and magnetic ruler attachment.\u003c\/p\u003e\n\u003cp\u003eThe integrated software makes it easy to set up and allows you to choose between manual or automatic operation. Set the immersion and withdrawal properties independently to create both constant and variable film thicknesses. You can save 10 different programmes, each of which can store up to 20 routines, to coat multiple substrates without needing to reconfigure the device each time.\u003c\/p\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Quick_release_or_Speed.svg?v=1697701268\" loading=\"lazy\" height=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eWide Range of Speeds\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eFrom 0.05 to 125 mm.s\u003csup\u003e-1\u003c\/sup\u003e\u003cbr\u003efor different coating thicknesses\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Full_Control.svg?v=1697622912\" loading=\"lazy\" height=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eSmooth, Precise Motion\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eHigh performance motor\u003cbr\u003efor accuracy and reproducibility\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Fewer_variables_better_films.svg?v=1697623210\" loading=\"lazy\" height=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eVariable Withdrawal Speed\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eSet immersion \u0026amp; withdrawal independently for gradient films\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Full_Control.svg?v=1718795142\" loading=\"lazy\" height=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eManual or Automatic Control\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eSave your custom dip coating\u003cbr\u003eparameters and cycles\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure class=\"video\"\u003e\n\u003cimg class=\"video-poster\" loading=\"lazy\" src=\"https:\/\/cdn.ossila.com\/videos\/dip-coater-product-overview.jpg\" draggable=\"false\" height=\"675\" width=\"1200\"\u003e\n  \u003cvideo class=\"widescreen\" controls=\"controls\" controlslist=\"nodownload\" crossorigin=\"\" height=\"675\" width=\"1200\" preload=\"none\" title=\"Dip coater overview\"\u003e\n\u003csource type=\"video\/mp4\" src=\"https:\/\/cdn.ossila.com\/videos\/dip-coater-product-overview.mp4\"\u003e\n\u003ctrack srclang=\"en\" src=\"https:\/\/cdn.ossila.com\/videos\/dip-coater-product-overview.vtt\" label=\"English\" kind=\"subtitles\" default=\"\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"Ossila Dip Coater Product Overview\",\n\"description\": \"Ossila Dip Coater Product Overview\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/dip-coater-product-overview.jpg\",\n\"uploadDate\": \"2023-11-29\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/dip-coater-product-overview.mp4\",\n\"duration\": \"PT0M24S\"\n}\n\u003c\/script\u003e\u003c\/figure\u003e\n\u003ch2 id=\"specification\"\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable style=\"height: 305.398px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22.4432px;\"\u003e\n\u003cth style=\"width: 38.0937%; height: 22.4432px;\" width=\"38.2%\"\u003eMinimum Withdrawal Rate\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%; height: 22.4432px;\"\u003e0.05 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.4432px;\"\u003e\n\u003cth style=\"width: 38.0937%; height: 22.4432px;\" width=\"38.2%\"\u003eMaximum Withdrawal Rate\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%; height: 22.4432px;\"\u003e125 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44.8864px;\"\u003e\n\u003cth style=\"width: 38.0937%; height: 44.8864px;\" width=\"38.2%\"\u003eRate Reproducibility\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%; height: 44.8864px;\"\u003e±0.01% @ 1 mm.s\u003csup\u003e-1\u003c\/sup\u003e ; ± 0.1% @ 10 mm.s\u003csup\u003e-1\u003c\/sup\u003e ; ± 0.3% @ \u0026gt;50 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 38.0937%; height: 19.6023px;\" width=\"38.2%\"\u003eMaximum Travel Distance\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%; height: 19.6023px;\"\u003e175 mm (6.89\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 38.0937%; height: 19.6023px;\" width=\"38.2%\"\u003eMaximum Number of Cycles\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%; height: 19.6023px;\"\u003e1,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003cth style=\"width: 38.0937%; height: 39.2045px;\" width=\"38.2%\"\u003eMaximum Timer Duration (HH:MM:SS)\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%; height: 39.2045px;\"\u003e99:59:59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003cth style=\"width: 38.0937%; height: 39.2045px;\" width=\"38.2%\"\u003eIntegrated Software Features\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%; height: 39.2045px;\"\u003eVariable withdrawal speed, repeat cycles, crash detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 38.0937%; height: 19.6023px;\" width=\"38.2%\"\u003eProgrammes\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%; height: 19.6023px;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 38.0937%; height: 19.6023px;\" width=\"38.2%\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%; height: 19.6023px;\"\u003eDC 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003cth style=\"width: 38.0937%; height: 39.2045px;\" width=\"38.2%\"\u003eProduct Dimensions (W x H x D)\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%; height: 39.2045px;\"\u003e200 mm x 380 mm (580 mm fully extended) x 300 mm (7.87\" x 14.96\" [22.83\"] x 11.81\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003cth style=\"width: 38.0937%; height: 19.6023px;\" width=\"38.2%\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 61.5359%; height: 19.6023px;\"\u003e3.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg width=\"400\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Product_Wireframes_Dip_Coater.svg\" loading=\"lazy\" height=\"558\" alt=\"Ossila Dip Coater wireframe\"\u003e\u003c\/figure\u003e\n\u003ch3\u003eUser Manual\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"Ossila Dip Coater user manual\" rel=\"noopener noreferrer\" href=\"https:\/\/downloads.ossila.com\/manuals\/dip-coater-v2.pdf\" target=\"_blank\"\u003e\u003cimg width=\"30\" style=\"margin-right: 12px;\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" loading=\"lazy\" height=\"30\" alt=\"Dip coater user manual\"\u003eDip Coater V2 user manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eDip Coat High Quality Films\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Full_Control.svg?v=1697622912\" loading=\"lazy\" height=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003ePrecision Motor for Reproducibility\u003c\/p\u003e\n\u003cp\u003eWe have developed a motor with a high degree of accuracy and reproducibility for a smooth motion profile. You can be sure that each time you coat your sample, you will get the same results every time. The crash detection system can detect when the substrate or arm crashes into the base of the coater or a beaker. To reduce the chance of damaging your samples or equipment, the motor stops automatically.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Large_Range_of_Speeds.svg?v=1697622577\" loading=\"lazy\" height=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eCustomizable Thickness and Gradient\u003c\/p\u003e\n\u003cp\u003eWithdraw your substrate from the solution at varying rates as low as 0.05 mm\/s up to 125 mm\/s. Customize your films to fit your required coating thicknesses using one dip coating system. For high quality gradient films, the speed of withdrawal can be varied across the substrate length. Optimize your film characteristics and produce films suitable for a wide range of research applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Quick_release_or_Speed.svg?v=1697701268\" loading=\"lazy\" height=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eStreamlined Coating Processes\u003c\/p\u003e\n\u003cp\u003eThe quick release clamp design lets you quickly load and unload samples onto the dip coater arm. Streamline your experimental process with a system that tackles workflow issues. integrated software makes it easy to set up and allows you to choose between manual or automatic operation. Save programs and routines to coat multiple substrates without reconfiguring the settings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eDip Coater Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-Dip-Coater.jpg?width=1620\" class=\"carousel-item\" title=\"Ossila Dip Coater\"\u003e \u003cimg width=\"420\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-Dip-Coater.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" alt=\"Ossila Dip Coater\"\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/High-performance-Dip-Coater.jpg?width=1620\" class=\"carousel-item\" title=\"High performance Dip Coater\"\u003e \u003cimg width=\"420\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/High-performance-Dip-Coater.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" alt=\"High performance Dip Coater\"\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Precision-Dip-Coating-Set-up.jpg?width=1620\" title=\"Precision Dip Coating Set up\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Precision-Dip-Coating-Set-up.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" alt=\"Precision Dip Coating Set up\"\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Precision-Dip-Coating.jpg?width=1620\" class=\"carousel-item\" title=\"Precision Dip Coating\"\u003e \u003cimg width=\"420\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Precision-Dip-Coating.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" alt=\"Precision Dip Coating\"\u003e \u003c\/a\u003e \u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-High-Performance-Dip-Coater.jpg?width=1620\" class=\"carousel-item\" title=\"Ossila High Perforamnce Dip Coater\"\u003e \u003cimg width=\"420\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-High-Performance-Dip-Coater.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" alt=\"Ossila High Perforamnce Dip Coater\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca class=\"carousel-left-control\" role=\"button\"\u003e \u003csvg class=\"icon icon-chevron-left\" aria-hidden=\"true\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious\u003c\/span\u003e \u003c\/a\u003e \u003ca class=\"carousel-right-control\" role=\"button\"\u003e \u003csvg class=\"icon icon-chevron-right\" aria-hidden=\"true\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"resources\"\u003eResources\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\" data-tags=\"written-guide, dip-coater, wet-thin-film-coating, organic-semiconductors\"\u003e\n\u003ca href=\"\/pages\/dip-coating\"\u003e\u003cimg alt=\"Dip Coating: Practical Guide to Theory and Troubleshooting\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/dip-coating-flow-of-solution.svg?v=16763896798\"\u003e\u003c\/a\u003e\u003ca href=\"\/pages\/dip-coating\"\u003e Dip Coating: Practical Guide to Theory and Troubleshooting\u003c\/a\u003e\n\u003cp\u003eDip coating is low-cost to set up and maintain, and can produce films with extremely high uniformity and a roughness of nanometers. Within research and development, it has become an important coating method for the fabrication of thin films using a purpose-built dip coater.\u003c\/p\u003e\n\u003ca href=\"\/pages\/dip-coating\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Type B (US)","offer_id":8806311133301,"sku":"L2006A2-US","price":2000.0,"currency_code":"GBP","in_stock":true},{"title":"Type F (EU)","offer_id":12376293376117,"sku":"L2006A2-EU","price":2000.0,"currency_code":"GBP","in_stock":true},{"title":"Type G (UK)","offer_id":8806309101685,"sku":"L2006A2-UK","price":2000.0,"currency_code":"GBP","in_stock":true},{"title":"Type I (AU)","offer_id":12376293671029,"sku":"L2006A2-AU","price":2000.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/dip-coater-product-photo.jpg?v=1768824612"},{"product_id":"molybdenum-disulfide","title":"Molybdenum Disulfide (MoS2) Crystal","description":"\u003ch2 id=\"product-oneliner\"\u003eMolybdenum disulfide crystal, one of the most studied and celebrated TMDCs\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eHighly anisotropic with excellent nonlinear optical properties\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#technical-data\"\u003eTechnical Data\u003c\/a\u003e | \u003ca href=\"#msds\"\u003eMSDS\u003c\/a\u003e | \u003ca href=\"#structure\"\u003eStructure\u003c\/a\u003e | \u003ca href=\"#literature\"\u003eLiterature and Reviews\u003c\/a\u003e | \u003ca href=\"#related-products\"\u003eRelated Products\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eMolybdenum disulfide (MoS\u003csub\u003e2\u003c\/sub\u003e), CAS number 1317-33-5, is a member of the transition metal dichalcogenides (TMDC) family. Due to its natural availability as molybdenite, it is one of the most studied and celebrated TMDCs.\u003c\/p\u003e\n\u003cp\u003eLike graphene, MoS\u003csub\u003e2\u003c\/sub\u003e has a similar two-dimensional layered structure, with each individual layer stacked upon each other to form the bulk single crystal. Each layer of MoS\u003csub\u003e2\u003c\/sub\u003e is composed of a plane of hexagonally-arranged molybdenum atoms, positioned between two planes of hexagonally-arranged sulfur atoms. Like graphite, each layer is bound by weak van der Waals forces. Because of this, it is possible to obtain monolayer to few-layer crystal flakes from a bulk crystal via mechanical exfoliation (using scotch tape).\u003c\/p\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"High Purity Molybdenum Disulfide\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2D-Materials-Icons_-Purity.svg?v=1698159365\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eHigh Purity\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eHigh purity ≥99.999% MoS2 Crystal\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 margin-top text-center\"\u003e\n\u003cimg alt=\"Worldwide shipping for 1317-33-5\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2D-Materials-Icons_-Free_ish_Shipping.svg?v=1698159365\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eWorldwide Shipping\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eQuick and reliable shipping\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Low Cost 1317-33-5\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Low_Cost.svg?v=1697194884\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eLow Cost\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eLow Cost Molybdenum Disulfide\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Wide range of applications\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Versitile.svg?v=1697195129\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eWide Range of Applications\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eApplications in electronic and optoelectronic devices\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eMoS\u003csub\u003e2 \u003c\/sub\u003ehas an indirect band-gap of 1.23 eV for bulk single crystal or multi-layer films. However, single atomic layers have a direct band-gap of 1.9 eV. Due to its layered structure, MoS\u003csub\u003e2\u003c\/sub\u003e is highly anisotropic with excellent nonlinear optical properties. It is widely used as a high-performance lubricant.\u003c\/p\u003e\n\u003cp\u003eAs a result of its direct band-gap, single-layer MoS\u003csub\u003e2\u003c\/sub\u003e has received much interest for applications in electronic and optoelectronic devices (such as transistors, photodetectors, photovoltaics and light-emitting diodes). It is also being explored for applications in photonics, and can be combined with other TMDCs to create advanced heterostructured devices.\u003c\/p\u003e\n\u003cp\u003eMolybdenum disulfide\u003csub\u003e \u003c\/sub\u003eis manufactured via chemical vapor transport (CVT) crystallization, with purities of over 99.999% achieved. It can used to create monolayer and few-layer MoS\u003csub\u003e2\u003c\/sub\u003e by mechanical or liquid exfoliation. Single crystals can also be studied using a range of microscopies (including AFM and TEM).\u003c\/p\u003e\n\u003ch2 id=\"technical-data\"\u003eTechnical Data\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eCAS Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"61.8%\"\u003e1317-33-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eChemical Formula\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoS\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eMolecular Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160.07 g\/mol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eBandgap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.23 eV [1]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003ePreparation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSynthetic - Chemical Vapor Transport (CVT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eStructure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHexagonal 2H\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eElectronic Properties\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2D semiconductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eMelting Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2375 °C (lit.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack \/ Dark brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eSynonyms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolybdenum sulfide, Molybdenum disulfide, Molybdenum(IV) sulfide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eClassification \/ Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransition metal dichalcogenides (TMDCs), 2D semiconductor materials, Nano-electronics, Nano-photonics, Materials science\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eForm\u003c\/th\u003e\n\u003cth width=\"61.8%\"\u003ePurity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003eCrystal, 2H\u003c\/td\u003e\n\u003ctd\u003e≥99.999%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePricing Table\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Code\u003c\/th\u003e\n\u003cth width=\"20%\"\u003eForm\u003c\/th\u003e\n\u003cth\u003eSize*\u003c\/th\u003e\n\u003cth\u003eQuantity (EA)\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eM2107A10\u003c\/td\u003e\n\u003ctd\u003eCrystal\u003c\/td\u003e\n\u003ctd\u003eSmall (10 × 10 mm)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"460\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM2107A15\u003c\/td\u003e\n\u003ctd\u003eCrystal\u003c\/td\u003e\n\u003ctd\u003eMedium (15 × 15 mm)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"850\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM2107A20\u003c\/td\u003e\n\u003ctd\u003eCrystal\u003c\/td\u003e\n\u003ctd\u003eLarge** (20 × 20 mm)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e[[price gbp=\"1150\"]]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"no-margin\"\u003e* Typical representative size, areas\/dimensions may vary\u003c\/p\u003e\n\u003cp\u003e** Item with a lead time of 2 - 3 weeks, \u003cstrong\u003e\u003ca href=\"https:\/\/www.ossila.com\/pages\/contact-us\" title=\"Contact us\"\u003eplease contact\u003c\/a\u003e\u003c\/strong\u003e for more information\u003c\/p\u003e\n\u003ch2 id=\"msds\"\u003eMSDS Document\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/msds\/molybdenum-disulfide.pdf\" title=\"Molybdenum disulfide crystal MSDS sheet\"\u003e\u003cimg alt=\"Molybdenum disulfide crystal MSDS\" class=\"msds-icon\" height=\"38.672\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/product-downloads-msds.svg\" width=\"30\"\u003eMolybdenum disulfide crystal\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"structure\"\u003eMolybdenum Disulfide Structure\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/MoS2-structure-product-image.png\" target=\"_blank\" title=\"MoS2 structure\"\u003e\u003cimg alt=\"Molybdenum disulfide crystal structure\" height=\"213\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/MoS2-structure-product-image.png?v=1543854449\u0026amp;width=848\u0026amp;height=213\" width=\"848\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eThe hexagonal structure of Molybdenum Disulfide (MoS\u003csub\u003e2\u003c\/sub\u003e)\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch2 id=\"literature\"\u003eLiterature and References\u003c\/h2\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cem\u003eFew-Layer MoS2: A Promising Layered Semiconductor,\u003c\/em\u003e R. Ganatra et al., ACS Nano, 8 (5), 4074–4099 (2014); DOI: 10.1021\/nn405938z.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eAtomically Thin MoS2: A New Direct-Gap Semiconductor,\u003c\/em\u003e K. Mak et al., Phys. Rev. Lett. 105, 136805 (2015); DOI: 10.1103\/PhysRevLett.105.136805.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eShape-Uniform, High-Quality Monolayered MoS2 Crystals for Gate-Tunable Photoluminescence,\u003c\/em\u003e X. Zhang et al., ACS Appl. Mater. Interfaces, 9, 42121−42130 (2017); DOI: 10.1021\/acsami.7b14189.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"expandable\" id=\"literature-and-reviews\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cem\u003ePhotoluminescence from Chemically Exfoliated MoS2, \u003c\/em\u003eG. Eda et al., Nano Lett., 11, 5111–5116 (2011); DOI: 10.1021\/nl201874w.\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eFabrication of Single- and Multilayer MoS2 Film-Based Field-Effect Transistors for Sensing NO at Room Temperature,\u003c\/em\u003e H. Li et al, Small, 8 (1), 63–67 (2012); DOI: 10.1002\/smll.201101016.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbutton class=\"anchor expand-link\" data-expand-target=\"literature-and-reviews\" data-toggle-text=\"Hide Literature and Reviews\" type=\"button\"\u003eView Literature and Reviews\u003c\/button\u003e\u003c\/p\u003e\n\u003ch2 id=\"related-products\"\u003eRelated Products\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eWe stock a wide range of 2D materials available to purchase online. Please \u003ca href=\"https:\/\/www.ossila.com\/pages\/contact-us\" title=\"Contact Us\"\u003econtact us\u003c\/a\u003e if you cannot find what you are looking for.\u003c\/p\u003e\n\u003cdiv class=\"collection-container\"\u003e\n\u003cdiv class=\"collection-tile\"\u003e\n\u003ca href=\"\/collections\/transition-metal-dichalcogenides\"\u003e\n\u003cdiv class=\"collection-button background-ossila-blue\"\u003e\n\u003cimg alt=\"Transition Metal Dichalcogenides Collection\" height=\"109\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Molybdenum-Diselenide-collection-design.png?v=1713516072\" width=\"150\"\u003e\n\u003cp\u003eTMDs\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/transition-metal-dichalcogenides\"\u003eTransition Metal Dichalcogenides (TMDs)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"collection-tile\"\u003e\n\u003ca href=\"\/collections\/transition-metal-chalcogenides-tmcs\"\u003e\n\u003cdiv class=\"collection-button background-light-blue\"\u003e\n\u003cimg alt=\"Transition Metal Chalcogenides Collection\" height=\"109\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Transition-metal-chalcogenides-collection-design.png?v=1713516072\" width=\"150\"\u003e\n\u003cp\u003eTMCs\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ossila.com\/collections\/transition-metal-chalcogenides-tmcs\"\u003eTransition Metal Chalcogenides (TMCs)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"collection-tile\"\u003e\n\u003ca href=\"\/collections\/2d-materials\"\u003e\n\u003cdiv class=\"collection-button background-ossila-blue\"\u003e\n\u003cimg alt=\"2D materials collection\" height=\"109.266\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/collection-link-2D-materials.png?v=1708091282\" width=\"150\"\u003e\n\u003cp\u003e2D Materials\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/2d-materials\"\u003e2D Materials\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"col-xs-12 button-col\"\u003e\n\u003cdiv class=\"card-box\"\u003e\n\u003ch3 class=\"h4\"\u003eViscoelastic Transfer of 2D Material Using PDMS\u003c\/h3\u003e\n\u003cp\u003eViscoelastic transfer using polydimethylsiloxane (PDMS) stamps is one of the methods used for the deterministic placement of 2D materials and the fabrication of van der Waals heterostructures. It relies on the viscoelasticity of PDMS, which behaves as an elastic solid on short time scales, but as a viscous fluid on long time scales.\u003c\/p\u003e\n\u003ca href=\"\/pages\/viscoelastic-transfer-of-2d-material-using-pdms\"\u003eLearn more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Ossila","offers":[{"title":"Small (10 × 10 mm)","offer_id":8787533987957,"sku":"M2107A10","price":330.0,"currency_code":"GBP","in_stock":true},{"title":"Medium (15 × 15 mm)","offer_id":8789029191797,"sku":"M2107A15","price":850.0,"currency_code":"GBP","in_stock":true},{"title":"Large (20 × 20 mm)","offer_id":8789030535285,"sku":"M2107A20","price":1150.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/M2107A10.png?v=1719310407"},{"product_id":"xtralien-source-measure-unit-source-meter","title":"Source Measure Unit","description":"\u003ch2 id=\"product-oneliner\"\u003eDual Channel System for Versatile I-V Measurements\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eSource voltage and measure voltage \u0026amp; current reliably and easily\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#software\"\u003eSoftware\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#included\"\u003eIn the Box\u003c\/a\u003e | \u003ca href=\"#related-products\"\u003eRelated Products\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eDesigned for scientists and engineers working on the next generation of electronic devices. Combine the capabilities of several instruments to power and measure device performance at the same time, saving bench space, time, and reducing programming issues. The Ossila Source Measure Unit is ideal for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLED and OLED characterization\u003c\/li\u003e\n\u003cli\u003eSolar cell I-V curves and stability measurements\u003c\/li\u003e\n\u003cli\u003eMeasuring transistor properties, such as current gain\u003c\/li\u003e\n\u003cli\u003eMeasuring battery discharge rates (V Sense channels only)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasuring material conductivity, leakage currents, and other properties\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe dual channel system sources voltage while simultaneously measuring current and voltage, and contains four instruments on one board: two SMUs (voltage source, current sense) and two precision voltage sense channels. For useful integration, the general-purpose shutter\/trigger makes it possible to send and receive control signals to and from other instruments.\u003c\/p\u003e\n\u003cp\u003eFor a simple solution that does the work for you, take a look at our \u003ca href=\"#related-products\"\u003esolar cell and LED test systems\u003c\/a\u003e, which have been purpose-built to streamline your research with intuitive software and no need for programming knowledge. Alternatively, for a complete set up, consider the electrical characterization system, which includes a probe station and set of a micromanipulators.\u003c\/p\u003e\n\u003cdiv class=\"row display-flex padding-bottom\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Processing_icons_Interchangeable.svg\" loading=\"lazy\" height=\"50\" alt=\"Source measure unit with two-year warranty\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eShutter\/Trigger Functionality\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eIntegrate with other components\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Voltage.svg?v=1697197768\" loading=\"lazy\" height=\"50\" alt=\"SMU with a versatile voltage range\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eUseful Current \u0026amp; Voltage Range\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eWith five independent channels\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon-Compact.svg?v=1718795142\" loading=\"lazy\" height=\"50\" alt=\"Compact source measure unit\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eCompact, Space-saving Instrument\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eOnly 185 mm x 125 mm x 55 mm\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon-Free-Software-Update.svg?v=1697197697\" loading=\"lazy\" height=\"50\" alt=\"Compatible with Ossila software\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eFree, Easy-to-use Software\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eOr use your preferred language\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel panel-default no-margin\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cblockquote class=\"marks\"\u003eThe Source Measure Unit is a professional alternative to old-fashioned and outdated bench top source-measure units at a fraction of cost. Ossila's product was thoroughly tested by us, it had to compete with state-of-art devices and to our surprise it won the race in all categories: precise PV measurements, networking capabilities, flexibility of programming language and smooth operation in pretty tough chemical\/material science laboratories. The Ossila team has delivered a game changer for all of the PV community.\u003c\/blockquote\u003e\n\u003cp class=\"text-right\"\u003eAdam Surmiak, PhD Student in Excitonic Systems for Solar Energy Conversion, Monash University\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure class=\"pad-top\"\u003e\u003cvideo width=\"848.328\" title=\"Source Measure Unit. Product Overview video\" preload=\"none\" poster=\"https:\/\/cdn.ossila.com\/videos\/source-measure-unit-product-overview.jpg\" height=\"477.172\" crossorigin=\"\" controlslist=\"nodownload\" controls=\"controls\" class=\"widescreen\"\u003e\n\u003csource type=\"video\/mp4\" src=\"https:\/\/cdn.ossila.com\/videos\/source-measure-unit-product-overview-1080p.mp4\"\u003e\n\u003ctrack srclang=\"en\" src=\"https:\/\/cdn.ossila.com\/videos\/source-measure-unit-product-overview.vtt\" label=\"English\" kind=\"subtitles\" default=\"\"\u003e\u003c\/video\u003e \u003c\/figure\u003e\n\u003ch2 id=\"specification\"\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eSource Measure Units (SMU 1 \u0026amp; SMU 2)\u003c\/h3\u003e\n\u003cp\u003eThe SMUs output a voltage and then measure both the voltage and current. The output voltage is always measured on the output to the BNC, rather than assuming it is at the set voltage. This is to account for any load effects, for example, short circuiting the output, or low impedance causing a small drop in voltage. Each source measure unit has multiple current ranges, so that you can measure both large and small currents with accuracy.\u003c\/p\u003e\n\u003ch4\u003eVoltage Source Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eRange\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eAccuracy\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003ePrecision\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eResolution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±10 V\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e10 mV\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e333 µV\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e170 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eVoltage Measure Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eRange\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eAccuracy\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003ePrecision\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eResolution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±10V\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e10 mV\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e50 µV\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e10 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCurrent Measure Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"16.66%\" class=\"text-center\"\u003eRange\u003c\/th\u003e\n\u003cth width=\"16.66%\" class=\"text-center\"\u003eMax Current\u003c\/th\u003e\n\u003cth width=\"16.66%\" class=\"text-center\"\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003cth width=\"16.66%\" class=\"text-center\"\u003ePrecision\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003cth width=\"16.66%\" class=\"text-center\"\u003eResolution\u003c\/th\u003e\n\u003cth width=\"16.66%\" class=\"text-center\"\u003eBurden\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e1\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e±200 mA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e±500 µA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e10 µA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e1 µA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e\u0026lt;20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e2\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e±20 mA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e±10 µA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e1 µA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e100 nA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e\u0026lt;20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e3\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e±2 mA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e±1 µA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e100 nA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e10 nA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e\u0026lt;20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e4\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e±200 µA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e±100 nA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e10 nA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e1 nA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e\u0026lt;20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e5\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e±20 µA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e±10 nA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e1 nA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e0.1nA\u003c\/td\u003e\n\u003ctd width=\"16.66%\" class=\"text-center\"\u003e\u0026lt;20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"text-small\"\u003e\u003csup\u003e1\u003c\/sup\u003eAccuracy has been measured at the maximum current of the range.\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003ePrecision has been measured at the highest OSR (9).\u003c\/p\u003e\n\u003ch3\u003ePrecision Voltage Meter Specifications (Vsense 1 and Vsense 2)\u003c\/h3\u003e\n\u003cp\u003eThe voltage meters are designed to accurately sense small voltages while also having a wide dynamic range (±10 V).\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eRange\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eAccuracy\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003ePrecision\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eResolution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e±10 V\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e10 mV\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e50 µV\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e10 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eShutter\/Trigger\u003c\/h3\u003e\n\u003cp\u003eThe Shutter\/Trigger can be used either as an input or an output. It can be used to send a trigger signal to other instruments or configured to wait for a trigger from other instruments. The voltage level of this BNC is 5 V because any higher may cause damage to the port.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg width=\"725\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/source-measure-unit-front-panel.png?v=latest\" loading=\"lazy\" height=\"400.987\" alt=\"Ossila Source Measure Unit front panel\"\u003e\n\u003cfigcaption\u003eThe front panel of the Ossila Source Measure Unit highlighting the SMU and Vsense channels\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003ca href=\"#specifications-continued\"\u003eSee more specifications\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eSource Measure Unit Features\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Large_Range_of_Speeds.svg?v=1697622577\" loading=\"lazy\" height=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eStreamline Your Workflow\u003c\/p\u003e\n\u003cp\u003eWith multiple functions integrated into one system, you can take multiple measurements in rapid succession; great for obtaining quick snapshots of devices (e.g. I-V curves) or for measuring dynamic behavior. An affordable and effective alternative to the big names on the market, this source measure unit offers your lab, no matter the size or budget, the capability to improve the accuracy and speed of your research.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Versitile.svg?v=1697195129\" loading=\"lazy\" height=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eFlexible \u0026amp; Scalable Research\u003c\/p\u003e\n\u003cp\u003eWhen your electronic devices need to be tested under both positive and negative voltages, handle negative values without resetting the system or rearranging your setup. As your research grows, the Ossila Source Measure Unit makes it easy to expand your experimental capabilities by connecting the source measure unit via USB, or using several units at the same time via Ethernet connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Simple_to_use_Software.svg?v=1697198301\" loading=\"lazy\" height=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eKeeping Measurements Simple\u003c\/p\u003e\n\u003cp\u003eEasy to programme, the free SMU Front Panel software balances usability and functionality. The system is also compatible with many of our measurement-specific software. For ultimate control, you can control the source measure unit with your chosen programming language, including Python, MATLAB, Java, C\/C++, and more. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"software\"\u003eSoftware\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eThe Ossila Source Measure Unit includes Front Panel software that enables you to start taking measurements as quickly as possible. With the program you can:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl each SMU and Vsense channel independently, allowing you to perform many of the most common electrical measurements.\u003c\/li\u003e\n\u003cli\u003eSet voltage and measure current with two independent SMU channels (voltage source, current sense).\u003c\/li\u003e\n\u003cli\u003eQuickly and accurately measure voltages with the two Vsense channels.\u003c\/li\u003e\n\u003cli\u003eEasily set sampling rates for the SMUs and Vsense channels via the interface.\u003c\/li\u003e\n\u003cli\u003eSave your data as a portable spreadsheet (.csv) file or a text (.txt) file for analysis with your favorite software package.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cfigure class=\"padding-top\"\u003e\u003cimg width=\"848.328\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/source-measure-unit-front-panel-software.png?width=848\" loading=\"lazy\" height=\"615.941\" alt=\"Ossila Source Measure Unit Software Front Panel\"\u003e\n\u003cfigcaption\u003eOssila Source Measure Unit Front Panel PC Software\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cfigure\u003e\u003cvideo width=\"848.328\" title=\"Source Measure Unit Software\" preload=\"none\" poster=\"https:\/\/cdn.ossila.com\/videos\/source-measure-unit-software-video.jpg\" height=\"477.172\" crossorigin=\"\" controlslist=\"nodownload\" controls=\"controls\" class=\"widescreen\"\u003e\n\u003csource type=\"video\/mp4\" src=\"https:\/\/cdn.ossila.com\/videos\/source-measure-unit-software-video.mp4\"\u003e\n\u003ctrack srclang=\"en\" src=\"https:\/\/cdn.ossila.com\/videos\/source-measure-unit-software-video.vtt\" label=\"English\" kind=\"subtitles\" default=\"\"\u003e\u003c\/video\u003e \n\u003cfigcaption\u003eUsing Source Measure Unit Software\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOther Software\u003c\/h3\u003e\n\u003cp\u003eWe also have software for performing specific measurements with the Ossila Source Measure Unit. These can be downloaded for free from our \u003ca title=\"Source Measure Unit Software\" href=\"\/pages\/software-drivers\"\u003esoftware and drivers page\u003c\/a\u003e. The currently available measurements are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI-V curves\u003c\/li\u003e\n\u003cli\u003eSolar cell characterization and lifetime\u003c\/li\u003e\n\u003cli\u003eFour-point probe sheet resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProgramming Languages\u003c\/h3\u003e\n\u003cp\u003eThe user-friendly design works with almost any programming language. Common languages that can be used to interface to it are:\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg width=\"30\" style=\"float: left; padding-right: 10px;\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" loading=\"lazy\" height=\"30\" alt=\"Check mark\"\u003ePython\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg width=\"30\" style=\"float: left; padding-right: 10px;\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" loading=\"lazy\" height=\"30\" alt=\"Check mark\"\u003eLabVIEW™\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg width=\"30\" style=\"float: left; padding-right: 10px;\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" loading=\"lazy\" height=\"30\" alt=\"Check mark\"\u003eMATLAB\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg width=\"30\" style=\"float: left; padding-right: 10px;\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" loading=\"lazy\" height=\"30\" alt=\"Check mark\"\u003eJava\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg width=\"30\" style=\"float: left; padding-right: 10px;\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" loading=\"lazy\" height=\"30\" alt=\"Check mark\"\u003eVB\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg width=\"30\" style=\"float: left; padding-right: 10px;\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" loading=\"lazy\" height=\"30\" alt=\"Check mark\"\u003eWolfram\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg width=\"30\" style=\"float: left; padding-right: 10px;\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" loading=\"lazy\" height=\"30\" alt=\"Check mark\"\u003eC\/C++\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg width=\"30\" style=\"float: left; padding-right: 10px;\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" loading=\"lazy\" height=\"30\" alt=\"Check mark\"\u003ePerl\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSoftware Requirements\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eOperating System\u003c\/th\u003e\n\u003ctd\u003eWindows 11 (64-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCPU\u003c\/th\u003e\n\u003ctd\u003eDual Core 2 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eRAM\u003c\/th\u003e\n\u003ctd\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAvailable Drive Space\u003c\/th\u003e\n\u003ctd\u003e201 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003eUSB 2.0, or Ethernet (requires DHCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"gallery\"\u003eSource Measure Unit Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca title=\"Ossila Source Measure Unit channels\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Source-measure-unit-close-up-resize.jpg?width=1620\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Source-measure-unit-close-up-resize.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"Ossila Source Measure Unit channels\"\u003e \u003c\/a\u003e \u003ca title=\"SMU Connection\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Source-measure-unit-with-solar-simulator.jpg?width=1620\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Source-measure-unit-with-solar-simulator.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"SMU Connection\"\u003e \u003c\/a\u003e \u003ca title=\"Ossila SMU display\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/connection-points-ossila-smu.jpg?width=1620\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/connection-points-ossila-smu.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"Ossila SMU display\"\u003e \u003c\/a\u003e \u003ca title=\"Ossila Source Measure Unit\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/SMU-with-display.jpg?width=1620\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/SMU-with-display.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"Ossila Source Measure Unit\"\u003e \u003c\/a\u003e \u003ca title=\"Ossila SMU\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Source-measure-unit-Back.jpg?width=1620\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Source-measure-unit-Back.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"Ossila SMU\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca role=\"button\" class=\"carousel-left-control\"\u003e \u003csvg class=\"icon icon-chevron-left\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious\u003c\/span\u003e \u003c\/a\u003e \u003ca role=\"button\" class=\"carousel-right-control\"\u003e \u003csvg class=\"icon icon-chevron-right\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"specifications-continued\"\u003eAdditional Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure\u003e\u003cimg width=\"415\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Product_Wireframes_X200_Source_Measure_Unit.svg?v=1709633899\" loading=\"lazy\" height=\"329\" alt=\"Ossila Source Measure Unit wireframe diagram\"\u003e\n\u003cfigcaption\u003eOssila Source Measure Unit wireframe\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePhysical Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eComputer Connectivity\u003c\/th\u003e\n\u003ctd\u003eUSB-B and Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMeasurement Connections\u003c\/th\u003e\n\u003ctd\u003eBNC connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e185 mm x 125 mm x 55 mm (7.28\" x 4.92\" x 2.17\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"Ossila Source Measure Unit manual\" rel=\"noopener noreferrer\" href=\"https:\/\/downloads.ossila.com\/manuals\/xtralien-source-measure-unit-source-meter.pdf\" target=\"_blank\"\u003e\u003cimg width=\"30\" style=\"margin-right: 12px;\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" loading=\"lazy\" height=\"30\" alt=\"Ossila Source Measure Unit manual\"\u003eSource Measure Unit user manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Ossila Source Measure Unit programming documentation\" rel=\"noopener noreferrer\" href=\"https:\/\/downloads.ossila.com\/manuals\/source-measure-unit-programming-documentation.pdf\" target=\"_blank\"\u003e\u003cimg width=\"30\" style=\"margin-right: 12px;\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" loading=\"lazy\" height=\"30\" alt=\"Ossila Source Measure Unit programming documentation\"\u003eSource Measure Unit programming documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"included\"\u003eIn the Box\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eThe standard items included with the Ossila Source Measure Unit are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSource measure unit\u003c\/li\u003e\n\u003cli\u003e24 V \/ 2 A DC power adapter\u003c\/li\u003e\n\u003cli\u003eUSB-B cable\u003c\/li\u003e\n\u003cli\u003eUser manual and QC data\u003c\/li\u003e\n\u003cli\u003eUSB drivers and Front Panel software installer\u003c\/li\u003e\n\u003cli\u003eUSB Driver with QC test data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"related-products\"\u003eRelated Products\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/products\/probe-station-electrical-characterization\"\u003e \u003cimg width=\"150\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/probe-station-kit-product-photo.jpg?v=1758533808\u0026amp;width=150\" loading=\"lazy\" height=\"150\" alt=\"Electrical Characterization System\"\u003e \u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ossila.com\/products\/probe-station-electrical-characterization\"\u003eElectrical Characterization System\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe complete electrical characterization kit. Includes a probe station, four micromanipulators, a source measure unit, a set of tungsten probe tips, two differential interfaces, and a set of cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/products\/solar-cell-iv-test-system\"\u003e\u003cimg width=\"150\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Solar_Cell_I-V_Test_System_20_x15mm_-_White_Background_S2006.jpg?width=150\" loading=\"lazy\" height=\"150\" alt=\"Solar Cell I-V Test System\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ossila.com\/products\/solar-cell-iv-test-system\"\u003eSolar Cell I-V Test System\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eTake control of your solar cell measurements with a simple and reliable system for PV characterization. The free PC software automatically calculates key properties of solar cells from the measured I-V curves.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/products\/led-measurement-system\"\u003e\u003cimg width=\"150\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/LED_Test_System_20_x_15mm_-_Product_Photo.jpg?width=150\" loading=\"lazy\" height=\"150\" alt=\"LED Measurement System\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ossila.com\/products\/led-measurement-system\"\u003eLED Measurement System\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eA complete solution for LED characterization and lifetime measurements. Perform I-V measurements, calculate the current and power efficiencies, and set a constant voltage and measure performance over an extended time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eIf you are looking for a flexible solution for OEM applications, the \u003ca href=\"https:\/\/www.ossila.com\/products\/oem-source-measure-unit\"\u003eOEM Source Measure Unit Set\u003c\/a\u003e includes 5 source measure unit PCBs for a discounted price.\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/iv-curves-measurement\"\u003e\u003cimg src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/page-iv-curves-measurement.jpg?crop=center\u0026amp;width=160\u0026amp;height=160\" loading=\"lazy\" height=\"160\" alt=\"I-V Curves: A Guide to Measurement\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/iv-curves-measurement\"\u003e I-V Curves: A Guide to Measurement\u003c\/a\u003e\n\u003cp\u003eAn I-V curve (short for 'current-voltage characteristic curve'), is a graphical representation of the relationship between the voltage applied across an electrical device and the current flowing through it.\u003c\/p\u003e\n\u003ca href=\"\/pages\/iv-curves-measurement\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/source-measure-unit-quickstart-guide\"\u003e\u003cimg src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Quickstart-guide-smu.jpg?crop=center\u0026amp;width=160\u0026amp;height=160\" loading=\"lazy\" height=\"160\" alt=\"SMU Quickstart Guide\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/source-measure-unit-quickstart-guide\"\u003e SMU Quickstart Guide\u003c\/a\u003e\n\u003cp\u003eThe latest quick start guide for the Ossila Source Measure Unit, to set up your device\u003c\/p\u003e\n\u003ca href=\"\/pages\/source-measure-unit-quickstart-guide\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Default Title","offer_id":18590416535648,"sku":"P2005A2","price":1400.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/source-measure-unit-featured-image.jpg?v=1768819336"},{"product_id":"spin-coater-syringe-pump-bundle","title":"Spin Coating System","description":"\u003ch2 id=\"product-oneliner\"\u003eStart Automating Your Coating Process with the Ossila Spin Coating System\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eCombine spin coater uniformity with syringe-pump controlled deposition for automated, repeatable thin film fabrication.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#included\"\u003eIn the Box\u003c\/a\u003e | \u003ca href=\"#accessories\"\u003eAccessories\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eThe Ossila Spin Coating System combines a spin coater and syringe pump, with a connection adapter, disposable syringes, PTFE tubing, and needles - everything you need to improve your spin coating. This system allows you to combine the uniformity and easy optimization of the Ossila spin coater, with the precise deposition of an Ossila syringe pump. This saves users time and stress during labour-intensive depositions, while making experiments more repeatable and minimizing human error.\u003c\/p\u003e\n\u003cp\u003eUp to four different solutions can be dispensed separately, great for layer-by-layer spin coating, antisolvent quenching or any other complex processing technique. Standard manual dispensing can still be carried out too, without needing to remove the adapter.\u003c\/p\u003e\n\u003cp\u003eThe bundle comes with a multi-substrate chuck and is available with any combination of our syringe pump and spin coater models. Choose the right system to fit your research needs and start automating your spin coating process.\u003c\/p\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Two-Year Warranty\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Glove_Box_key_Features__Two_year_warranty.svg?v=1718707947\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eTwo-Year Warranty\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eBuy with confidence\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 margin-top text-center\"\u003e\n\u003cimg alt=\"Syringe Compatibility\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Syring_Compatability.svg?v=1698413426\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eUniversal Syringe Clamps\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eFor 0.5 μl to 60 ml syringes\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Full Control\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Full_Control.svg?v=1697622912\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eFull Control\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eSave recipes with up to 50 steps\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Compact and Lab-Proof\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Lab_Proof.svg?v=1697623210\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eCompact and Lab Proof\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eDurable and solvent-safe\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure\u003e\u003cvideo class=\"widescreen\" controls=\"controls\" controlslist=\"nodownload\" crossorigin=\"\" height=\"477.172\" poster=\"https:\/\/cdn.ossila.com\/videos\/Spin-Coating-Kit-Product-Overview.jpg\" preload=\"none\" title=\"Spin Coater Kit. Product Overview video\" width=\"848.328\"\u003e\n\u003csource src=\"https:\/\/cdn.ossila.com\/videos\/Spin-Coating-Kit-Product-Overview-1080p.mp4\" type=\"video\/mp4\"\u003e\n\u003ctrack default=\"\" kind=\"subtitles\" label=\"English\" src=\"https:\/\/cdn.ossila.com\/videos\/Spin-Coating-Kit-Product-Overview.vtt\" srclang=\"en\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"Ossila Spin Coating Kit Product Overview\",\n\"description\": \"Spin Coating Kit Product Overview\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/Spin-Coating-Kit-Product-Overview.jpg\",\n\"uploadDate\": \"2023-04-19\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/Spin-Coating-Kit-Product-Overview-1080p.mp4\",\n\"duration\": \"PT0M24S\"\n}\n\u003c\/script\u003e\n\u003cfigcaption\u003eSpin Coating System Product Overview\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch2 id=\"specification\"\u003eSpin Coater Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cbr\u003e\u003c\/th\u003e\n\u003cth\u003eStandard V3 (L2001A3)\u003c\/th\u003e\n\u003cth\u003eAdvanced V2 (L2001B2)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpeed Stability\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;2% error\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.25% error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpeed\u003c\/th\u003e\n\u003ctd\u003e120 – 6,000 rpm\u003c\/td\u003e\n\u003ctd\u003e500 – 10,000 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAcceleration Control\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDeceleration Control\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Acceleration\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e4000 rpm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Deceleration\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e700 rpm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMinimum Acc\/Dec\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e10 rpm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpin Time\u003c\/th\u003e\n\u003ctd\u003e1 – 1,000 sec\u003c\/td\u003e\n\u003ctd\u003e1 – 3,600 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eUser Profiles\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePrograms per User\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaterials\u003c\/th\u003e\n\u003ctd\u003ePolypropylene bowl, steel casing, tempered glass lid\u003c\/td\u003e\n\u003ctd\u003ePTFE bowl, powder coated steel casing, tempered glass lid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e2.75 kg\u003c\/td\u003e\n\u003ctd\u003e3.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMax Substrate Size\u003c\/th\u003e\n\u003ctd\u003e100 mm (4\") diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePrograms\u003c\/th\u003e\n\u003ctd\u003e10 programs, , with up to 50 steps each, on each user profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSafety Switch\u003c\/th\u003e\n\u003ctd\u003eMagnetic safety switch on the door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAdditional Features\u003c\/th\u003e\n\u003ctd\u003eBuilt-in spirit level and adjustable feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDimensions (D x W x H)\u003c\/th\u003e\n\u003ctd\u003e225 mm x 170 mm x 140 mm (8.86\" x 6.69\" x 5.51\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eDC 24 V 2 A, via 100–240 V 50\/60 Hz power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg alt=\"Ossila Spin Coater Wireframe\" height=\"337\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Product_Wireframes_Spin_Coater.svg?v=1709633899\" width=\"488\"\u003e\n\u003cfigcaption\u003eOssila Spin Coater Wireframe\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSpin Coater Chuck Specifications\u003c\/h3\u003e\n\u003ch4\u003eL2001U1\/L2001U2 Standard Spin Coater Chuck\u003c\/h4\u003e\n\u003cp\u003eChoose between polypropylene, PTFE, or PEEK chuck material depending on your application. The design incorporates all of the most commonly used substrates including:\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003e20mm x 15mm\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003e25mm x 25mm (1\" x 1\")\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003e50mm x 50mm (2\" x 2\")\u003c\/div\u003e\n\u003cdiv class=\"col-xs-3\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003e75mm x 25mm (3\" x 1\")\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003ePlus, our chucks also have:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA rimmed edge to improve air flow uniformity and reduce solvent build up within the bowl.\u003c\/li\u003e\n\u003cli\u003eSimplified drainage channels to reduce buffeting and improve the stability of the chuck.\u003c\/li\u003e\n\u003cli\u003eFinger cutouts for easy removal of chucks, allowing you to switch them for different experiments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cfigure\u003e\u003cimg alt=\"Ossila Standard Spin Coater Chuck\" height=\"424.144\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Standard-Chuck-L2003U1.png?v=1715088455\" width=\"600\"\u003e\n\u003cfigcaption\u003eOur standard chuck suitable for four standard substrate types (all dimensions in mm)\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCustom Chucks\u003c\/h3\u003e\n\u003cp\u003eCustom chucks are available at a discounted price with the purchase of a spin coater, but can also be purchased separately. Please contact us to discuss your needs, specifying the length, width, and height of each substrate. Alternatively, STL, STEP, and SLDPRT files (for AutoCAD \/ FreeCAD and SolidWorks respectively) are freely available to download should you wish to create your own chucks.\u003c\/p\u003e\n\u003ch4 class=\"padding-top\"\u003eCustom Chuck Requirements\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Chuck Diameter\u003c\/th\u003e\n\u003ctd\u003e115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Substrate Diameter\u003c\/th\u003e\n\u003ctd\u003e100 mm (4\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eBlank Chuck Downloads\u003c\/h4\u003e\n\u003cp\u003eVersion 2\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/downloads.ossila.com\/resources\/ossila-custom-chuck-blank-v2.stl\" title=\"Blank Custom Chuck Download\"\u003e.STL\u003c\/a\u003e file for AutoCad and FreeCad\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/downloads.ossila.com\/resources\/ossila-custom-chuck-blank-v2.step\" title=\"Blank Custom Chuk Download\"\u003e.STEP\u003c\/a\u003e file for AutoCad and FreeCad\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/downloads.ossila.com\/resources\/ossila-custom-chuck-blank-v2.sldprt\" title=\"Blank Custom Chuck Download\"\u003e.SLDPRT\u003c\/a\u003e file for SolidWorks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVersion 1\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/downloads.ossila.com\/resources\/ossila-custom-chuck.stl\"\u003e.STL file\u003c\/a\u003e for AutoCAD and TurboCAD\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/downloads.ossila.com\/resources\/ossila-custom-chuck.sldprt\"\u003e.SLDPRT file\u003c\/a\u003e for SolidWorks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eManual\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/manuals\/spin-coater.pdf\" rel=\"noopener noreferrer\" title=\"Spin coater manual\" target=\"_blank\"\u003e\u003cimg alt=\"Spin coater user manual\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px;\" width=\"30\"\u003eSpin Coater user manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/manuals\/spin-coater-advanced.pdf\" rel=\"noopener noreferrer\" title=\"Spin coater manual\" target=\"_blank\"\u003e\u003cimg alt=\"Spin coater user manual\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px;\" width=\"30\"\u003eSpin Coater Advanced user manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSyringe Pump Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003e\u003c\/th\u003e\n\u003cth\u003eSingle Syringe Pump\u003c\/th\u003e\n\u003cth\u003eDual Syringe Pump\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSyringe Channels\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eChannel Dependency\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eIndependent channel control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eOverall Dimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e240 mm x 150 mm x 150 mm\u003cbr\u003e(9.8\" x 6.1\" x 6.1\")\u003c\/td\u003e\n\u003ctd\u003e240 mm x 150 mm x 260 mm\u003cbr\u003e(9.8\" x 6.1\" x 10.2\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdditional Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eOperation Modes\u003c\/th\u003e\n\u003ctd\u003eInfusion and withdrawal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMinimum Syringe Size\u003c\/th\u003e\n\u003ctd\u003e0.5 μl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Syringe Size\u003c\/th\u003e\n\u003ctd\u003e60 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSafety Features\u003c\/th\u003e\n\u003ctd\u003eLimit switches, crashing sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003e24 V DC, 2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePower Supply Input Voltage Range\u003c\/th\u003e\n\u003ctd\u003e100 – 230 V, 50\/60 Hz, 50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e5 °C – 40 °C (41 °F – 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Humidity\u003c\/th\u003e\n\u003ctd\u003eUp to 80% RH at 31 °C (87.8 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg alt=\"Ossila Single Syringe Pump wireframe\" height=\"521\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/syringe-pumps-single-and-double.svg?v=1709633900\" width=\"754\"\u003e\u003c\/figure\u003e\n\u003ch3\u003eMotor\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMotor Type\u003c\/th\u003e\n\u003ctd\u003eNEMA 17 stepper motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eStep Angle\u003c\/th\u003e\n\u003ctd\u003e1.8°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSteps per Full Revolution\u003c\/th\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eScrew Pitch\u003c\/th\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eTravel per Step\u003c\/th\u003e\n\u003ctd\u003e5 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Linear Force\u003c\/th\u003e\n\u003ctd\u003e500 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDriver\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMicro Stepping\u003c\/th\u003e\n\u003ctd\u003e1\/128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMicro Steps per Revolution\u003c\/th\u003e\n\u003ctd\u003e25,600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Speed\u003c\/th\u003e\n\u003ctd\u003e1,000 steps.s\u003csup\u003e-1\u003c\/sup\u003e; 5mm.s\u003csup\u003e-1\u003c\/sup\u003e; 300mm.min\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMinimum Speed\u003c\/th\u003e\n\u003ctd\u003e0.015 steps.s\u003csup\u003e-1\u003c\/sup\u003e; 75nm.s\u003csup\u003e-1\u003c\/sup\u003e; 4.5µm.min\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eRate Accuracy**\u003c\/th\u003e\n\u003ctd\u003e±0.16%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e** The Ossila Single Syringe Pump has a stepping accuracy of 0.16%, which gives a rate accuracy of 19 nm.s\u003csup\u003e-1\u003c\/sup\u003e. In practice, the accuracy of the flow rate from a syringe pump depends on the accuracy of the driver and the syringe diameter. Different syringes have different manufacturing tolerances. The diameter of plastic disposable syringes can vary by up to 3%, resulting in an error in dispense rate of up to 6%. Glass and stainless steel syringes have a higher tolerance, with a maximum of 0.5% variation in the internal diameter and volume error of up to 1%.\u003c\/p\u003e\n\u003ch3\u003eSoftware\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eNumber of Programs\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSteps per Program\u003c\/th\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSyringe Size Settings\u003c\/th\u003e\n\u003ctd\u003e5 pre-sets, 1 customizable diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eForce Tuning\u003c\/th\u003e\n\u003ctd\u003e5% – 100% (5% increments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMemory\u003c\/th\u003e\n\u003ctd\u003eNon-volatile memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSyringe Compatibility\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-4\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eNorm-Ject syringes\u003c\/div\u003e\n\u003cdiv class=\"col-xs-4\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eHenke Sass Wolf (HSW)\u003c\/div\u003e\n\u003cdiv class=\"col-xs-4\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eTerumo Plastic\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-4\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eHamilton Gastight\u003c\/div\u003e\n\u003cdiv class=\"col-xs-4\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eHamilton Microliter\u003c\/div\u003e\n\u003cdiv class=\"col-xs-4\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eAir-Tite Syringes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-4\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eBD Plastic\u003c\/div\u003e\n\u003cdiv class=\"col-xs-4\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eBD Glass\u003c\/div\u003e\n\u003cdiv class=\"col-xs-4\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eSGE Syringes\u003c\/div\u003e\n\u003cdiv class=\"col-xs-4\"\u003e\n\u003cimg alt=\"Check Mark\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/tick.svg?v=1613513177\" style=\"float: left; padding-right: 10px;\" width=\"30\"\u003eAnd more...\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eMaximum and Minimum Flow Rate\u003c\/h3\u003e\n\u003cp\u003eThe maximum and minimum flow rate of the syringe pump is determined by the stepping rate of the motor and the diameter of the syringe. Maximum and minimum flow rates for some common syringe sizes are shown below. By choosing the correct syringe diameter, it is possible to achieve a range of dispense rates spanning 8 orders of magnitude.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"19.1%\"\u003eSyringe Volume\u003c\/th\u003e\n\u003cth width=\"19.1%\"\u003eSyringe Diameter\u003c\/th\u003e\n\u003cth style=\"vertical-align: middle;\" width=\"31.4%\"\u003eMinimum Flow Rate\u003c\/th\u003e\n\u003cth style=\"vertical-align: middle;\" width=\"31.4%\"\u003eMaximum Flow Rate\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5 µl\u003c\/td\u003e\n\u003ctd\u003e0.103 mm\u003c\/td\u003e\n\u003ctd\u003e0.6 pl.s\u003csup\u003e-1\u003c\/sup\u003e (2.1 nl.hr\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003ctd\u003e42 nl.s\u003csup\u003e-1\u003c\/sup\u003e (0.15 ml.hr\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 µl\u003c\/td\u003e\n\u003ctd\u003e0.46 mm\u003c\/td\u003e\n\u003ctd\u003e12.5 pl.s\u003csup\u003e-1\u003c\/sup\u003e (45 nl.hr\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003ctd\u003e0.8 µl.s\u003csup\u003e-1\u003c\/sup\u003e (3 ml.hr\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 µl\u003c\/td\u003e\n\u003ctd\u003e1.46 mm\u003c\/td\u003e\n\u003ctd\u003e0.1 nl.s\u003csup\u003e-1\u003c\/sup\u003e (0.36 µl.hr\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003ctd\u003e8.4 µl.s\u003csup\u003e-1\u003c\/sup\u003e (29.8 ml.hr\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 ml\u003c\/td\u003e\n\u003ctd\u003e4.61 mm\u003c\/td\u003e\n\u003ctd\u003e1.3 nl.s\u003csup\u003e-1\u003c\/sup\u003e (4.7 µl.hr\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003ctd\u003e84 µl.s\u003csup\u003e-1\u003c\/sup\u003e (298 ml.hr\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 ml\u003c\/td\u003e\n\u003ctd\u003e10.3 mm\u003c\/td\u003e\n\u003ctd\u003e6.3 nl.s\u003csup\u003e-1\u003c\/sup\u003e (22.7 µl.hr\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003ctd\u003e0.4 ml.s\u003csup\u003e-1\u003c\/sup\u003e (1.5 l.hr\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 ml\u003c\/td\u003e\n\u003ctd\u003e32.6 mm\u003c\/td\u003e\n\u003ctd\u003e62.6 nl.s\u003csup\u003e-1\u003c\/sup\u003e (225 µl.hr\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003ctd\u003e4.2 ml.s\u003csup\u003e-1\u003c\/sup\u003e (15 l.hr\u003csup\u003e-1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Certification and Standards\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCE\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eMachinery Directive 2006\/42\/EC\u003c\/p\u003e\n\u003cp\u003eEMC Directive 2014\/30\/EU\u003c\/p\u003e\nRoHS Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eUKCA\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eSupply of Machinery (Safety) Regulations\u003c\/p\u003e\n\u003cp\u003eElectromagnetic Compatibility Regulations\u003c\/p\u003e\nRestriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eInternational Standards\u003c\/th\u003e\n\u003ctd\u003eBS EN ISO 12100:2010 Safety of Machinery - General Principles for Design - Risk Assessment and Risk Reduction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eUser Manual\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/manuals\/syringe-pump-v2.pdf\" title=\"Ossila Single Syringe Pump user manual\" target=\"_blank\"\u003e\u003cimg alt=\"Single syringe pump user manual\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px;\" width=\"30\"\u003eSingle Syringe Pump user manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/manuals\/syringe-pump-v2.pdf\" rel=\"noopener\" title=\"Ossila Dual Syringe Pump user manual\" target=\"_blank\"\u003e\u003cimg alt=\"Dual syringe pump user manual\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px;\" width=\"30\"\u003eDual Syringe Pump user manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eSpin Coating System Features\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Built-In Software\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Free_Software.svg?v=1697195052\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eBuilt-In Software\u003c\/p\u003e\n\u003cp\u003eNo external PC required, both the Syringe Pump and Spin Coater feature built-in software which allows multi-step programs to be created and saved with ease.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Complete Control\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Full_Control.svg?v=1697622912\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eComplete Control\u003c\/p\u003e\n\u003cp\u003eTake your spin coating to the next level. Together, the Spin Coater and Syringe Pump give you complete control over the spin speed and the solution dispense rate and volume, with a high degree of precision. Easily and accurately reproduce your experiments every time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"More Applications\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Five_Current_Range.svg?v=1697203063\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eMore Applications\u003c\/p\u003e\n\u003cp\u003eThere are many thin film applications that require more precise control over solution deposition. When anti-solvent quenching, it is important to allow a precise amount of time to pass after the initial solution before adding the solvent. Similarly, for synthesizing multilayered structures, a dual pump syringe pump is invaluable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Multiple Modes of Operation\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Versitile.svg?v=1697195129\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eMultiple Modes of Operation\u003c\/p\u003e\n\u003cp\u003eYou can use the spin coater and syringe pump together with the supplied adapter, or as separate units for any experiment that only requires one or the other. In addition, each syringe pump on the dual pump model can be controlled completely independently of the other.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Large Range of Spin and Dispense Speeds\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Quick_release_or_Speed.svg?v=1697701268\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eLarge Range of Spin and Flow Rates\u003c\/p\u003e\n\u003cp\u003eWith spin speeds from 120 rpm to 10,000 rpm across our spin coater range and syringe pump flow rates from \u003cspan\u003e2.1 nl.hr\u003c\/span\u003e\u003csup\u003e-1\u003c\/sup\u003e to \u003cspan\u003e15 l.hr\u003c\/span\u003e\u003csup\u003e-1\u003c\/sup\u003e, take complete and precise control of your thin film processes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Compact and Lab-Proof\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Lab_Proof.svg?v=1697623210\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eCompact and Lab-Proof\u003c\/p\u003e\n\u003cp\u003eThe compact design along with the high quality, durable, and solvent-safe construction of the two units make them suitable for busy labs and glove boxes. Since the spin coater is not burdened by a vacuum pump, it is easy to move from place-to-place to make room when space is limited.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eSpin Coating System Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"inline-block-container\"\u003e\n\u003cfigure class=\"double-float-left\"\u003e\u003cimg alt=\"The Ossila Spin Coating Kit\" class=\"fill\" height=\"304\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spin-coating-kit-close-up.jpg?width=424\u0026amp;height=283\" width=\"417.156\"\u003e\u003c\/figure\u003e\n\u003cfigure class=\"double-float-right\"\u003e\u003cimg alt=\"Spin coater syringe pump\" class=\"fill\" height=\"304\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spin-coater-syringe-pump-right-view.jpg\" width=\"417.156\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"included\"\u003eIn the Box\u003c\/h2\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eSpin coater\u003c\/li\u003e\n\u003cli\u003eSingle or dual syringe pump\u003c\/li\u003e\n\u003cli\u003eSpin coater adapter\u003c\/li\u003e\n\u003cli\u003eMulti-substrate chuck\u003c\/li\u003e\n\u003cli\u003eFifteen 5 ml Norm-Ject Disposable Luer Lock Syringes\u003c\/li\u003e\n\u003cli\u003eFive lengths of PTFE tubing with Luer Lock adapters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"accessories\"\u003eAccessories and Related Products\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e[[collection handle=\"solution-making\" limit=\"4\" show-more=\"false\"]]\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 button-col\"\u003e\n\u003cdiv class=\"card-box\"\u003e\n\u003ch3 class=\"h4\"\u003eHow to use the Spin Coater Syringe Adapter\u003c\/h3\u003e\n\u003cp\u003eSpin coating is one of the most popular techniques for creating thin-films. The method is quick, accurate, and easy to control. A spin coater like the Ossila Spin Coater allows you to control the spin speed and save recipes with up to 50 steps, and therefore allows you to create films of various thicknesses.\u003c\/p\u003e\n\u003ca href=\"\/pages\/how-to-use-the-spin-coater-syringe-adapter\"\u003eLearn more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Spin Coater + Single Syringe Pump \/ Multi-substrate PP \/ Type B (US)","offer_id":19350503456864,"sku":"L2001A3-L2003S2-U1-US","price":3050.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Single Syringe Pump \/ Multi-substrate PP \/ Type F (EU)","offer_id":19350495756384,"sku":"L2001A3-L2003S2-U1-EU","price":3050.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Single Syringe Pump \/ Multi-substrate PP \/ Type G (UK)","offer_id":19350503522400,"sku":"L2001A3-L2003S2-U1-UK","price":3050.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Single Syringe Pump \/ Multi-substrate PP \/ Type I (AU)","offer_id":19350503489632,"sku":"L2001A3-L2003S2-U1-AU","price":3050.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Single Syringe Pump \/ Multi-substrate PTFE \/ Type B (US)","offer_id":19350503587936,"sku":"L2001A3-L2003S2-U2-US","price":3125.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Single Syringe Pump \/ Multi-substrate PTFE \/ Type F (EU)","offer_id":19350503555168,"sku":"L2001A3-L2003S2-U2-EU","price":3125.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Single Syringe Pump \/ Multi-substrate PTFE \/ Type G (UK)","offer_id":19350503653472,"sku":"L2001A3-L2003S2-U2-UK","price":3125.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Single Syringe Pump \/ Multi-substrate PTFE \/ Type I (AU)","offer_id":19350503620704,"sku":"L2001A3-L2003S2-U2-AU","price":3125.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Single Syringe Pump \/ Custom PP \/ Type B (US)","offer_id":19350503719008,"sku":"L2001A3-L2003S2-B1-U101-US","price":3100.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Single Syringe Pump \/ Custom PP \/ Type F (EU)","offer_id":19350503686240,"sku":"L2001A3-L2003S2-B1-U101-EU","price":3100.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Single Syringe Pump \/ Custom PP \/ Type G (UK)","offer_id":19350503784544,"sku":"L2001A3-L2003S2-B1-U101-UK","price":3100.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Single Syringe Pump \/ Custom PP \/ Type I (AU)","offer_id":19350503751776,"sku":"L2001A3-L2003S2-B1-U101-AU","price":3100.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Single Syringe Pump \/ Custom PTFE \/ Type B (US)","offer_id":19350503850080,"sku":"L2001A3-L2003S2-U102-US","price":3250.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Single Syringe Pump \/ Custom PTFE \/ Type F (EU)","offer_id":19350503817312,"sku":"L2001A3-L2003S2-U102-EU","price":3250.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Single Syringe Pump \/ Custom PTFE \/ Type G (UK)","offer_id":19350503915616,"sku":"L2001A3-L2003S2-U102-UK","price":3250.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Single Syringe Pump \/ Custom PTFE \/ Type I (AU)","offer_id":19350503882848,"sku":"L2001A3-L2003S2-U102-AU","price":3250.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Dual Syringe Pump \/ Multi-substrate PP \/ Type B (US)","offer_id":19350503981152,"sku":"L2001A3-L2003D2-U1-US","price":3850.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Dual Syringe Pump \/ Multi-substrate PP \/ Type F (EU)","offer_id":19350503948384,"sku":"L2001A3-L2003D2-U1-EU","price":3850.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Dual Syringe Pump \/ Multi-substrate PP \/ Type G (UK)","offer_id":19350504079456,"sku":"L2001A3-L2003D2-U1-UK","price":3850.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Dual Syringe Pump \/ Multi-substrate PP \/ Type I (AU)","offer_id":19350504013920,"sku":"L2001A3-L2003D2-U1-AU","price":3850.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Dual Syringe Pump \/ Multi-substrate PTFE \/ Type B (US)","offer_id":19350504144992,"sku":"L2001A3-L2003D2-U2-US","price":3925.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Dual Syringe Pump \/ Multi-substrate PTFE \/ Type F (EU)","offer_id":19350504112224,"sku":"L2001A3-L2003D2-U2-EU","price":3925.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Dual Syringe Pump \/ Multi-substrate PTFE \/ Type G (UK)","offer_id":19350504210528,"sku":"L2001A3-L2003D2-U2-UK","price":3925.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Dual Syringe Pump \/ Multi-substrate PTFE \/ Type I (AU)","offer_id":19350504177760,"sku":"L2001A3-L2003D2-U2-AU","price":3925.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater + Dual Syringe Pump \/ Custom PP \/ Type B (US)","offer_id":19350504276064,"sku":"L2001A3-L2003D2-B1-U101-US","price":3900.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Dual Syringe Pump \/ Custom PP \/ Type F (EU)","offer_id":19350504243296,"sku":"L2001A3-L2003D2-B1-U101-EU","price":3900.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Dual Syringe Pump \/ Custom PP \/ Type G (UK)","offer_id":19350504341600,"sku":"L2001A3-L2003D2-B1-U101-UK","price":3900.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Dual Syringe Pump \/ Custom PP \/ Type I (AU)","offer_id":19350504308832,"sku":"L2001A3-L2003D2-B1-U101-AU","price":3900.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Dual Syringe Pump \/ Custom PTFE \/ Type B (US)","offer_id":19350504407136,"sku":"L2001A3-L2003D2-U102-US","price":4050.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Dual Syringe Pump \/ Custom PTFE \/ Type F (EU)","offer_id":19350504374368,"sku":"L2001A3-L2003D2-U102-EU","price":4050.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Dual Syringe Pump \/ Custom PTFE \/ Type G (UK)","offer_id":19350504472672,"sku":"L2001A3-L2003D2-U102-UK","price":4050.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater + Dual Syringe Pump \/ Custom PTFE \/ Type I (AU)","offer_id":19350504439904,"sku":"L2001A3-L2003D2-U102-AU","price":4050.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Multi-substrate PTFE \/ Type B (US)","offer_id":44965064638680,"sku":"L2001B2-L2003S2-U2-US","price":3550.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Multi-substrate PTFE \/ Type F (EU)","offer_id":44965064605912,"sku":"L2001B2-L2003S2-U2-EU","price":3550.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Multi-substrate PTFE \/ Type G (UK)","offer_id":44965064573144,"sku":"L2001B2-L2003S2-U2-UK","price":3550.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Multi-substrate PTFE \/ Type I (AU)","offer_id":44965064671448,"sku":"L2001B2-L2003S2-U2-AU","price":3550.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Multi-substrate PEEK \/ Type B (US)","offer_id":45266799591640,"sku":"L2001B2-L2003S2-U3-US","price":3650.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Multi-substrate PEEK \/ Type F (EU)","offer_id":45266799558872,"sku":"L2001B2-L2003S2-U3-EU","price":3650.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Multi-substrate PEEK \/ Type G (UK)","offer_id":45266799526104,"sku":"L2001B2-L2003S2-U3-UK","price":3650.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Multi-substrate PEEK \/ Type I (AU)","offer_id":45266799624408,"sku":"L2001B2-L2003S2-U3-AU","price":3650.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Custom PTFE \/ Type B (US)","offer_id":44965064769752,"sku":"L2001B2-L2003S2-U102-US","price":3675.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Custom PTFE \/ Type F (EU)","offer_id":44965064736984,"sku":"L2001B2-L2003S2-U102-EU","price":3675.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Custom PTFE \/ Type G (UK)","offer_id":44965064704216,"sku":"L2001B2-L2003S2-U102-UK","price":3675.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Custom PTFE \/ Type I (AU)","offer_id":44965064802520,"sku":"L2001B2-L2003S2-U102-AU","price":3675.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Custom PEEK \/ Type B (US)","offer_id":50506515251416,"sku":"L2001B2-L2003S2-U107-AU","price":3750.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Custom PEEK \/ Type F (EU)","offer_id":50506515284184,"sku":"L2001B2-L2003S2-U107-AU","price":3750.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Custom PEEK \/ Type G (UK)","offer_id":50506515316952,"sku":"L2001B2-L2003S2-U107-AU","price":3750.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Single Syringe Pump \/ Custom PEEK \/ Type I (AU)","offer_id":50506515349720,"sku":"L2001B2-L2003S2-U107-AU","price":3750.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Multi-substrate PTFE \/ Type B (US)","offer_id":44965064900824,"sku":"L2001B2-L2003D2-U2-US","price":4350.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Multi-substrate PTFE \/ Type F (EU)","offer_id":44965064868056,"sku":"L2001B2-L2003D2-U2-EU","price":4350.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Multi-substrate PTFE \/ Type G (UK)","offer_id":44965064835288,"sku":"L2001B2-L2003D2-U2-UK","price":4350.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Multi-substrate PTFE \/ Type I (AU)","offer_id":44965064933592,"sku":"L2001B2-L2003D2-U2-AU","price":4350.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Multi-substrate PEEK \/ Type B (US)","offer_id":45266799722712,"sku":"L2001B2-L2003D2-U3-US","price":4450.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Multi-substrate PEEK \/ Type F (EU)","offer_id":45266799689944,"sku":"L2001B2-L2003D2-U3-EU","price":4450.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Multi-substrate PEEK \/ Type G (UK)","offer_id":45266799657176,"sku":"L2001B2-L2003D2-U3-UK","price":4450.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Multi-substrate PEEK \/ Type I (AU)","offer_id":45266799755480,"sku":"L2001B2-L2003D2-U3-AU","price":4450.0,"currency_code":"GBP","in_stock":true},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Custom PTFE \/ Type B (US)","offer_id":44965065031896,"sku":"L2001B2-L2003D2-U102-US","price":4475.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Custom PTFE \/ Type F (EU)","offer_id":44965064999128,"sku":"L2001B2-L2003D2-U102-EU","price":4475.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Custom PTFE \/ Type G (UK)","offer_id":44965064966360,"sku":"L2001B2-L2003D2-U102-UK","price":4475.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Custom PTFE \/ Type I (AU)","offer_id":44965065064664,"sku":"L2001B2-L2003D2-U102-AU","price":4475.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Custom PEEK \/ Type B (US)","offer_id":50506515382488,"sku":"L2001B2-L2003D2-U107-US","price":4625.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Custom PEEK \/ Type F (EU)","offer_id":50506515415256,"sku":"L2001B2-L2003D2-U107-EU","price":4625.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Custom PEEK \/ Type G (UK)","offer_id":50506515448024,"sku":"L2001B2-L2003S2-U107-UK","price":4625.0,"currency_code":"GBP","in_stock":false},{"title":"Spin Coater Advanced + Dual Syringe Pump \/ Custom PEEK \/ Type I (AU)","offer_id":50506515480792,"sku":"L2001B2-L2003S2-U107-AU","price":4625.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/spin-coating-kit-product-photo.jpg?v=1768576912"},{"product_id":"potentiostat","title":"Potentiostat","description":"\u003ch2 id=\"product-oneliner\"\u003eLow Price Potentiostat for Cyclic Voltammetry and More\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eAvailable with electrochemical cell and electrodes for unbeatable value\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#software\"\u003eSoftware\u003c\/a\u003e | \u003ca href=\"#getting-started\"\u003eHow to Set Up\u003c\/a\u003e | \u003ca href=\"#understanding-potentiostats\"\u003eUnderstanding Potentiostats\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"#included\"\u003eIn the Box\u003c\/a\u003e | \u003ca href=\"#accessories\"\u003eRelated Products\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003ePerform linear sweep voltammetry, cyclic voltammetry, open circuit potential, and controlled potential electrolysis, with the powerful Ossila Potentiostat. You can be confident in your measurements with excellent applied potential and current measurement accuracy and a high applied potential and current measurement resolution.\u003c\/p\u003e\n\u003cp\u003eWhether you are an experienced chemist and or a newcomer to the field, the easy-to-use PC software makes it straightforward for anyone to take accurate and precise measurements across a wide potential and current range. Set the relevant parameters then watch the measurement as it happens with live data plotting.\u003c\/p\u003e\n\u003cp\u003eBuy as a standalone instrument to use with any electrochemical cell, or choose the complete kit which includes electrochemical glassware, your choice of non-aqueous Ag\/Ag+ or aqueous Ag\/AgCl reference electrode, a platinum disc working electrode, and a platinum wire counter electrode.\u003c\/p\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Available with cells and electrodes\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Easy_To_Use.svg?v=1718707947\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eAvailable as a Complete Kit\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eAdd electrochemical cell \u0026amp; electrodes\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Powerful potentiostat\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Powerful_Electronics-05.svg?v=1683217382\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003ePowerful Electronics\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003ePotential range of ±7.5 V\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Potentiostat for CV measurements and more\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Versitile.svg?v=1697195129\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eLow Price Characterization\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eCyclic voltammetry and more\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Potentiostat with free electrochemistry software\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon-Free-Software-Update.svg?v=1697194884\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eSimple-to-Use Software\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eFree software for easy measurements\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"specification\"\u003eKey Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePotential Range\u003c\/th\u003e\n\u003ctd\u003e±7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePotential Compliance\u003c\/th\u003e\n\u003ctd\u003e±10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eApplied Potential Accuracy\u003c\/th\u003e\n\u003ctd\u003e±10 mV offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eApplied Potential Resolution\u003c\/th\u003e\n\u003ctd\u003e333 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eScan Rate Range\u003c\/th\u003e\n\u003ctd\u003e5 mV\/s to 1000 mV\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Current\u003c\/th\u003e\n\u003ctd\u003e±200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCurrent Ranges\u003c\/th\u003e\n\u003ctd\u003e±20 μA to ±200 mA (5 ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCurrent Measurement Accuracy\u003c\/th\u003e\n\u003ctd\u003e±20 nA offset (at 20 μA range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCurrent Measurement Resolution\u003c\/th\u003e\n\u003ctd\u003e5 nA (at 20 μA range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eUSB-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eOverall Dimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e125 mm x 55 mm x 175 mm (4.91\" x 2.17\" x 6.89\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e600 g (1.32 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003ca href=\"#specifications-continued\"\u003eView more specifications\u003c\/a\u003e\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"Ossila Potentiostat Wireframe\" height=\"384\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Product_Wireframes_Potentiostat.svg?v=1709633899\" width=\"485\"\u003e\u003c\/figure\u003e\n\u003ch3\u003eUnderstanding Current Specifications\u003c\/h3\u003e\n\u003cp\u003eCurrent is the key measurement parameter for the potentiostat. It it important to know the requirements regarding this essential measurement. The current measurement by a potentiostat must fall within the maximum current with specific accuracy and resolution assigned to specific current ranges.\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\n\u003ch4\u003eSpecification\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-12\"\u003e\u003chr\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum current\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp\u003eThe highest electrical current that can be measured by a potentiostat for both positive and negative currents. If a measured current is outside of this range, a potentiostat will turn off the output potential to prevent damaging the unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent ranges\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp\u003eTo achieve a consistent level of accuracy and precision for current measurements at both milliamps and nanoamps, current measurements are split into a set of ranges. These ranges are typically separated by an order of magnitude, and whilst one range can usually measure the currents encompassed by the range below it, the accuracy and precision of the measurement will be worse.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp\u003eThe maximum amount that a measured current value can vary from the actual current value (scales with the order of magnitude of the current ranges). It is important to note that most measurements will vary by less than this amount.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp\u003eThe smallest change in current that can be measured by a potentiostat. This value scales with the order of magnitude of the current ranges.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eUnderstanding Voltage Specifications\u003c\/h3\u003e\n\u003cp\u003ePotential (voltage) is the key control parameter of a potentiostat. The range over which it can be swept, along with the precision, accuracy, and resolution of that control, are critical for acquiring meaningful electrochemical data.\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\n\u003ch4\u003eSpecification\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-12\"\u003e\u003chr\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\n\u003cp\u003e\u003cstrong\u003ePotential range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp\u003eThe potential window that can be applied and measured by a potentiostat between the working and reference electrodes. This typically applies for both positive and negative potential, and in such a case is represented with a plus\/minus symbol.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\n\u003cp\u003e\u003cstrong\u003ePotential compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp\u003eThe maximum limit for the potential that a potentiostat is capable of outputting between the working and counter electrodes. As with the potential range, it applies for both positive and negative potentials and as such is represented with a plus\/minus symbol.\u003c\/p\u003e\n\u003cp\u003eIt is important to note the distinction between the potential range and the potential compliance. Potential range is the applied and measured potential between the working and reference electrodes, whilst the potential compliance is the absolute maximum potential that can be applied between the working and counter electrodes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp\u003eThe maximum amount the output potential of a potentiostat can vary from the set potential (plus\/minus offset). Specifically, this refers to the potential between the working and reference electrodes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp\u003eAs a potentiostat uses digital signals to determine the potential to output, any change in potential will appear as a step, and a scan profile a series of steps over time. The applied potential resolution determines how small these steps can be, as it is the smallest change in potential that can be output by a potentiostat.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003ePotentiostat Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/electrochemistry-set-up-lab.jpg?width=1620\" title=\"Potentiostat for cyclic voltammetry and more\"\u003e \u003cimg alt=\"Potentiostat for cyclic voltammetry and more\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/electrochemistry-set-up-lab.jpg?width=420\u0026amp;height=280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Potentiostat-in-lab.jpg?width=1620\" title=\"Potentiostat in the lab\"\u003e \u003cimg alt=\"Potentiostat in the lab\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Potentiostat-in-lab.jpg?width=420\u0026amp;height=280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/potentiostat-electrochemistry-setup.jpg?width=1620\" title=\"Potentiostat connected to electrochemical cell\"\u003e \u003cimg alt=\"Potentiostat connected to electrochemical cell\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/potentiostat-electrochemistry-setup.jpg?width=420\u0026amp;height=280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/potentiostat-collection-bundle.jpg?width=1620\" title=\"potentiostat collection bundle\"\u003e \u003cimg alt=\"potentiostat collection bundle\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/potentiostat-collection-bundle.jpg?width=420\u0026amp;height=280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/potentiostat-lab.jpg?width=1620\" title=\"potentiostat in Lab\"\u003e \u003cimg alt=\"potentiostat in Lab\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/potentiostat-lab.jpg?width=420\u0026amp;height=280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/potentiostat-collection.jpg?width=1620\" title=\"potentiostat collection\"\u003e \u003cimg alt=\"potentiostat collection\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/potentiostat-collection.jpg?width=420\u0026amp;height=280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Potentiostat-in-lab-with-laptop.jpg?width=1620\" title=\"Powerful potentiostat\"\u003e \u003cimg alt=\"Powerful potentiostat\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Potentiostat-in-lab-with-laptop.jpg?width=420\u0026amp;height=280\" width=\"420\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca class=\"carousel-left-control\" role=\"button\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-left\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious \u003c\/span\u003e\u003c\/a\u003e \u003ca class=\"carousel-right-control\" role=\"button\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-right\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext \u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003cblockquote class=\"marks\"\u003eWe're happy with the Ossila Potentiostat. We're currently using it in teaching labs to demonstrate basics of corrosion measurements. It is compact, easy to use, and affordable.\u003c\/blockquote\u003e\n\u003cp class=\"text-right\"\u003eBranislav Dzurnak, Czech Technical University in Prague\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"software\"\u003eSoftware\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eEasily perform linear sweep and cyclic voltammetry, open circuit potential, and controlled potential electrolysis. The maximum and minimum potentials can be defined along with the number of cycles, the scan rate, and the current range. Simply set the relevant settings and click 'Start', then watch the measurement as it happens with live data plotting.\u003c\/p\u003e\n\u003cp\u003eSoftware updates are also provided at no extra charge and are available to download from our website.\u003c\/p\u003e\n\u003cfigure class=\"double-float-left\"\u003e\u003cvideo alt=\"Ossila Electrochemistry software\" autoplay=\"autoplay\" class=\"widescreen\" height=\"477.17\" loop=\"loop\" muted=\"muted\" src=\"https:\/\/cdn.ossila.com\/videos\/potentiostat-software-loop.mp4\" title=\"Ossila Electrochemistry software\" type=\"video\/mp4\" width=\"848.33\"\u003e\u003c\/video\u003e\u003c\/figure\u003e\n\u003cfigure class=\"double-float-right\"\u003e\u003cvideo class=\"widescreen\" controls=\"controls\" controlslist=\"nodownload\" crossorigin=\"\" height=\"477.172\" poster=\"https:\/\/cdn.ossila.com\/videos\/potentiostat-software-guide.jpg\" preload=\"none\" title=\"How to use the Ossila Potentiostat Software\" width=\"848.328\"\u003e\n\u003csource src=\"https:\/\/cdn.ossila.com\/videos\/potentiostat-software-guide.mp4\" type=\"video\/mp4\"\u003e\n\u003ctrack default=\"\" kind=\"subtitles\" label=\"English\" src=\"https:\/\/cdn.ossila.com\/videos\/potentiostat-software-guide.vtt\" srclang=\"en\"\u003e\u003c\/video\u003e\u003c\/figure\u003e\n\u003cp\u003eAs with all of our software, data is saved to .csv files so that you can analyze it with your favorite tool. The settings you define are saved alongside your measurement data so that you always have a record of your experimental parameters. Profiles allow you to save commonly used settings configurations so that you can quickly repeat measurements without re-configuring the potentiostat, further speeding up your research.\u003c\/p\u003e\n\u003ch3\u003eSoftware Requirements\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eOperating System\u003c\/th\u003e\n\u003ctd\u003eWindows 11 (64-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCPU\u003c\/th\u003e\n\u003ctd\u003eDual Core 2.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eRAM\u003c\/th\u003e\n\u003ctd\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAvailable Hard Drive Space\u003c\/th\u003e\n\u003ctd\u003e255 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMonitor Resolution\u003c\/th\u003e\n\u003ctd\u003e1280 x 960\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCommunication\u003c\/th\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"getting-started\"\u003eGetting Started with the Ossila Potentiostat\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eThe Ossila Potentiostat has been designed to make it quick and easy to perform electrochemistry. Purchase the complete package to get everything you need to set up your three electrode system and enjoy a significant discount on the cell and electrodes.\u003c\/p\u003e\n\u003ch3\u003eSetting Up the Potentiostat\u003c\/h3\u003e\n\u003cp\u003eThe Ossila Potentiostat is controlled by the (free to download and use) electrochemistry PC software. To get started, simply set up the physical aspects of your experiment and launch the software.\u003c\/p\u003e\n\u003cp\u003eThe experimental set up for cyclic voltammetry and other three electrode electrochemical methods consists of a potentiostat connected to a three electrode electrochemical cell containing the electrolyte solution. Once the electrodes have been placed in the cell, they can be connected to the socket on the front of the Ossila Potentiostat using the supplied cable and crocodile clips. The red clip connects to the working electrode, the black clip connects to the counter electrode, and the blue clip connects to the reference electrode.\u003c\/p\u003e\n\u003cp\u003eOnce you have set up your three electrode electrochemical cell and connected it to the potentiostat, taking an electrochemical measurement takes only a few clicks. The potentiostat will be detected automatically on starting the PC software, and from here the electrochemical method can be selected via the tabs at the top of the screen.\u003c\/p\u003e\n\u003cp\u003eWe also recommend switching on the potentiostat 30 minutes prior to use. This will allow it to warm up and reach a steady temperature, which will help to ensure a stable measurement.\u003c\/p\u003e\n\u003ch3\u003ePerforming Cyclic Voltammetry with the Potentiostat\u003c\/h3\u003e\n\u003cp\u003ePerforming cyclic voltammetry with the Ossila Potentiostat is quick and easy. The Ossila Electrochemistry PC software allows the maximum and minimum potentials to be defined along with the number of cycles, the scan rate, and the current range.\u003c\/p\u003e\n\u003cp\u003eWhen you are ready to start the scan, click \"Start\" and watch in real time as the test is performed and a cyclic voltammogram is generated. The system will sweep the potential between the working electrode and reference electrode while measuring the current between the working electrode and counter electrode. This will be repeated for the specified number of cycles. If \"Save After Measurement\" is turned on, the measurement data and settings will be saved as CSV file once the sweep has finished.\u003c\/p\u003e\n\u003cfigure\u003e\u003cvideo class=\"widescreen\" controls=\"controls\" controlslist=\"nodownload\" crossorigin=\"\" height=\"477.172\" poster=\"https:\/\/cdn.ossila.com\/videos\/potentiostat-quickstart-guide.jpg\" preload=\"none\" title=\"X200 Quickstart Guide\" width=\"848.328\"\u003e\n\u003csource src=\"https:\/\/cdn.ossila.com\/videos\/potentiostat-quickstart-guide-1080p.mp4\" type=\"video\/mp4\"\u003e\n\u003ctrack default=\"\" kind=\"subtitles\" label=\"English\" src=\"https:\/\/cdn.ossila.com\/videos\/potentiostat-quickstart-guide-caption-en.vtt\" srclang=\"en\"\u003e\u003c\/video\u003e\u003c\/figure\u003e\n\u003ch2 id=\"specifications-continued\"\u003eAdditional Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eStandard Electrochemical Cell Glassware (Optional)\u003c\/h3\u003e\n\u003cp\u003eScrew-fit PTFE lid with three electrode holes and two gas holes.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"Potentiostat standard electrochemical cell glassware\" height=\"290\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/electrochemical-cell-dimensions.svg?v=1579278066\u0026amp;width=520\" width=\"520\"\u003e\n\u003cfigcaption\u003eStandard electrochemical cell glassware dimensions (mm)\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePlatinum Disk Working Electrode (Optional)\u003c\/h3\u003e\n\u003cp\u003eHighly polished platinum embedded in polytetrafluoroethylene (PTFE) plastic bodies.\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePurity\u003c\/th\u003e\n\u003ctd\u003e99.99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDiameter\u003c\/th\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg alt=\"Platinum working electrode for potentiostat\" height=\"140\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/working-electrode-dimensions.svg?v=1579192563\" width=\"520\"\u003e\n\u003cfigcaption\u003ePlatinum working electrode dimensions (mm)\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePlatinum Wire Counter Electrode (Optional)\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePurity\u003c\/th\u003e\n\u003ctd\u003e99.99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDiameter\u003c\/th\u003e\n\u003ctd\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg alt=\"Platinum wire counter electrode for potentiostat\" height=\"140\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/pt-counter-electrode-dimensions.svg?v=1579192563\u0026amp;width=500\" width=\"500\"\u003e\n\u003cfigcaption\u003ePlatinum wire counter electrode dimensions (mm)\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNon-aqueous Ag\/Ag\u003csup\u003e+\u003c\/sup\u003e Reference Electrode (Optional)\u003c\/h3\u003e\n\u003cfigure\u003e\u003cimg alt=\"Ag\/Ag+ reference electrode for potentiostat\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ag-reference-electrode-dimensions.svg?v=1579192563\u0026amp;width=500\" width=\"500\"\u003e\n\u003cfigcaption\u003eAg\/Ag\u003csup\u003e+\u003c\/sup\u003e reference electrode dimensions (mm)\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAqueous Ag\/AgCl Reference Electrode (Optional)\u003c\/h3\u003e\n\u003cfigure\u003e\u003cimg alt=\"Ag\/AgCl reference electrode for potentiostat\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ag-agcl-reference-electrode-dimensions.svg?v=1579778461\u0026amp;width=500\u0026amp;height=280\" width=\"500\"\u003e\n\u003cfigcaption\u003eAg\/AgCl reference electrode dimensions (mm)\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eUser Manual\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/manuals\/potentiostat.pdf\" rel=\"noopener noreferrer\" title=\"Ossila Potentiostat user manual\" target=\"_blank\"\u003e\u003cimg alt=\"Ossila Potentiostat user manual\" height=\"30\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px;\" width=\"30\"\u003ePotentiostat user manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"understanding-potentiostats\"\u003eUnderstanding Potentiostats in Electrochemistry\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eElectrochemical techniques such as cyclic voltammetry, linear sweep voltammetry, and other types of voltammetry require a potentiostat to measure redox events taking place in a solution.\u003c\/p\u003e\n\u003cfigure class=\"float-right\"\u003e\u003cimg alt=\"electrochemistry set up\" height=\"318\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/potentiostat-collection-bundle.jpg?\u0026amp;width=489\u0026amp;height=318\" width=\"489\"\u003e\u003c\/figure\u003e\n\u003cp\u003eA typical electrochemical experimental set up consists of a potentiostat connected to a three-electrode cell via:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eworking electrode\u003c\/li\u003e\n\u003cli\u003ecounter electrode\u003c\/li\u003e\n\u003cli\u003ereference electrode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAnalysis of the data recorded by a potentiostat reveals various intrinsic electrochemical properties of the material, depending which method is used. Using techniques like cyclic voltammetry, potentiostats can be used to find the redox potential of materials, determine the reversibility of a reaction, provide a quantitative description of electrochemical reversibility, and determine the energy levels of semiconducting polymers.\u003c\/p\u003e\n\u003ch3\u003eHow Does a Potentiostat Work?\u003c\/h3\u003e\n\u003cp\u003eA potentiostat controls the potential difference between two electrodes and measures the resulting current flow. It is able to vary its output potential (voltage) in response to changes in the resistance across a circuit. In electrochemistry experiments, potentiostats are able to supply more or less current so that the potential across an electrochemically active cell remains constant as per Ohm’s Law: voltage (V) = current (I) x resistance (R).\u003c\/p\u003e\n\u003cp\u003eA potential is applied to the working electrode, which is held at a defined voltage relative to the reference electrode. The surface of the working electrode is the primary area of interest because, under an applied potential, the number of electrons at its surface changes (increases or decreases). The applied potential alters the electrochemical potential of the working electrode, making oxidation or reduction thermodynamically favorable. This drives the exchange of electrons between the electrode and species in the electrolyte. The specifics of this electron exchange depends on the chemical system under investigation.\u003c\/p\u003e\n\u003cp\u003eThe measured current is the exchange of electrons per time at the electrodes surface. The current flows between the working electrode and counter electrode (in a three electrode set up). Measuring current as a function of potential helps identify the point at which electron transfer is most efficient. This reveals key information about redox behavior, analyte concentration, and electrode performance. These characteristics are key to understanding and optimizing electrochemical reactions.\u003c\/p\u003e\n\u003ch3\u003eElectrochemical Methods\u003c\/h3\u003e\n\u003cp\u003eThe Ossila Potentiostat and Electrochemistry Software make it easy to perform the most commonly used electrochemical methods.\u003c\/p\u003e\n\u003ch4\u003eCyclic Voltammetry\u003c\/h4\u003e\n\u003cp\u003eOne of the most useful and commonly used electrochemical techniques. In cyclic voltammetry, a linearly ramping potential is applied between the working and reference electrodes. This potential is cycled such that the ramp is applied in one direction, then in reverse, forming a triangular wave. The electrical current is measured between the working and counter electrodes to produce a cyclic voltammogram.\u003c\/p\u003e\n\u003ch4\u003eLinear Sweep Voltammetry\u003c\/h4\u003e\n\u003cp\u003eLinear sweep voltammetry is an electrochemical method in which the potential is linearly swept in one direction from the lower potential limit to the upper potential limit. Linear sweep voltammetry is useful for irreversible systems and can be used to calculate the peak current, the peak current potential, and the half-peak current potential.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"electrochemistry set up\" height=\"309\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/potentiostat-electrochemistry-setup.jpg?\u0026amp;width=1340\u0026amp;height=390\u0026amp;crop=top\" width=\"1340\"\u003e\u003c\/figure\u003e\n\u003ch4\u003eControlled Potential Electrolysis\u003c\/h4\u003e\n\u003cp\u003eThree electrode controlled potential electrolysis is a type of bulk electrolysis (or potentiostatic coulometry) in which the potential between the working and reference electrodes is kept constant while the current through the cell is measured. As the analyte is reduced or oxidized, the measured current will approach zero.\u003c\/p\u003e\n\u003ch4\u003eOpen Circuit Potential\u003c\/h4\u003e\n\u003cp\u003eOpen circuit potential is an electrolytic method that can be used to measure the resting potential of an electrochemical cell between the reference and working electrodes. Systems that are in equilibrium over the timescale of the experiment will have a constant open circuit potential.\u003c\/p\u003e\n\u003ch3\u003eApplications of Cyclic Voltammetry\u003c\/h3\u003e\n\u003cp\u003eCyclic voltammetry reveals a number of important electrochemical properties about the material being investigated, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedox potentials.\u003c\/strong\u003e The reduction and oxidation potentials of a material describe how readily it gains or loses electrons. Reduction occurs when a chemical gains electron(s), and oxidation is when a chemical loses electron(s). Redox potential is an intrinsic property of materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe reversibility of a reaction.\u003c\/strong\u003e How reversible a given electrochemical reaction is. For a completely reversible reaction, the concentration of oxidized species and reduced species should be in equilibrium.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectron transfer kinetics.\u003c\/strong\u003e A quantitative description of electrochemical reversibility; how fast or slow the transfer of electrons is in a reaction. For a reaction to be reversible, electron transfer must be sufficiently fast.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy levels of \u003ca href=\"https:\/\/www.ossila.com\/collections\/semiconducting-polymers\"\u003esemiconducting polymers\u003c\/a\u003e.\u003c\/strong\u003e The energy levels of semiconducting materials. This is particularly useful for photovoltaic applications as it provides an estimate for the energy of the highest occupied (HOMO) and lowest unoccupied molecular orbitals (LUMO).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrochemical Cell Set-Up\u003c\/h3\u003e\n\u003cp\u003ePotentiostats can be used to control two, three or four electrode configurations (and as discussed above, multi-channel bipotentiostats or polypotentiostats can control rotating ring-disk electrode systems).\u003c\/p\u003e\n\u003cp\u003eThe three electrode set-up is by far the most common and consists of a working electrode, a counter electrode, and a reference electrode. Each of these three functions also exists in a two electrode cell, only a single interface both provides a reference potential and allows current to flow across the cell. The primary issue with such a set-up is that it renders it impossible to accurately control the potential at the working electrode.\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\n\u003cfigure\u003e\u003cimg alt=\"Platinum Disc Working Electrode\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Platinum-working-electrode-product-photo.jpg?crop=center\u0026amp;width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sxs-12 col-md-10\"\u003e\n\u003ch4\u003eWorking electrode\u003c\/h4\u003e\n\u003cp\u003eThe working electrode is the primary electrode in an electrochemical system. It is where the applied voltage enters the system, and where most electrochemical reactions and electron transfer take place. Measurements of potential and current in an electrochemical system involve the working electrode for both two and three-electrode systems.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\n\u003cfigure\u003e\u003cimg alt=\"Ag\/AgCl Reference Electrode\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ag-AgCl-product-photo.png?crop=center\u0026amp;width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sxs-12 col-md-10\"\u003e\n\u003ch4\u003eReference electrode\u003c\/h4\u003e\n\u003cp\u003eBy having a stable, known, and well-defined electrochemical potential, reference electrodes provide a constant for an electrochemical measurement. In an ideal electrochemical system, zero current will flow through the reference electrode, enabling accurate measurements and control of the potential at the working electrode. This is achieved by the reference electrode having a very low impedance, ideally zero.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\n\u003cfigure\u003e\u003cimg alt=\"Counter Electrode\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Platinum-wire-counter-electrode.jpg?crop=center\u0026amp;width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003ch4\u003eCounter electrode\u003c\/h4\u003e\n\u003cp\u003eCounter electrodes, also known as auxiliary electrodes, complete the circuit of a two or three-electrode system. In two-electrode systems, the counter electrode is also used as the reference electrode. In three-electrode systems, the current is measured between the working and counter electrodes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"included\"\u003eIn the Box\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-5\"\u003e\n\u003cul\u003e\n\u003cli\u003ePotentiostat\u003c\/li\u003e\n\u003cli\u003eShielded cable and crocodile clips\u003c\/li\u003e\n\u003cli\u003eTest cell chip\u003c\/li\u003e\n\u003cli\u003eUSB-B cable\u003c\/li\u003e\n\u003cli\u003e24 VDC power adapter\u003c\/li\u003e\n\u003cli\u003eUSB Driver with QC test data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-7\"\u003e\n\u003cp\u003eIncluded in complete kit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStandard electrochemical cell*\u003c\/li\u003e\n\u003cli\u003ePlatinum disc working electrode*\u003c\/li\u003e\n\u003cli\u003ePlatinum wire counter electrode*\u003c\/li\u003e\n\u003cli\u003eNon-aqueous Ag\/Ag\u003csup\u003e+\u003c\/sup\u003e or aqueous Ag\/AgCl reference electrode*\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e* Available to be purchased separately\u003c\/p\u003e\n\u003ch2 id=\"accessories\"\u003eAccessories and Related Products\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"collection-container\"\u003e\n\u003cdiv class=\"collection-tile\"\u003e\n\u003ca href=\"\/collections\/electrochemical-cells\"\u003e\n\u003cdiv class=\"collection-button background-ossila-blue\"\u003e\n\u003cimg alt=\"Electrochemical Cell Collection\" height=\"109\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/electrochemical-cell-collection-design.png?v=1715167619\" width=\"150\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrochemical Cells\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/electrochemical-cells\"\u003eElectrochemical Cells\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"collection-tile\"\u003e\n\u003ca href=\"\/collections\/photoelectrochemical-cells\"\u003e\n\u003cdiv class=\"collection-button background-light-blue\"\u003e\n\u003cimg alt=\"Photoelectrochemical Cell Collection\" height=\"109\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Photoelectrochemical-cells-collection-design.png?v=1715167619\" width=\"150\"\u003e\n\u003cp\u003e\u003cstrong\u003ePhotoelectrochemical Cells\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/photoelectrochemical-cells\"\u003ePhotoelectrochemical Cells\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"collection-tile\"\u003e\n\u003ca href=\"\/collections\/electrodes\"\u003e\n\u003cdiv class=\"collection-button background-ossila-blue\"\u003e\n\u003cimg alt=\"Electrochemical Cell Collection\" height=\"109\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Electrode-collection-design.png?v=1715167618\" width=\"150\"\u003e\n\u003cp\u003e\u003cstrong\u003eElectrodes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/electrodes\"\u003eElectrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"resources\"\u003eResources\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/how-to-perform-cyclic-voltammetry-on-a-polymer-using-a-potentiostat\"\u003e\u003cimg alt=\"How to Perform Cyclic Voltammetry on a Polymer\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/electrochemistry-pc-software-ferrocene.png?crop=right\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/how-to-perform-cyclic-voltammetry-on-a-polymer-using-a-potentiostat\"\u003eHow to Perform Cyclic Voltammetry on a Polymer\u003c\/a\u003e\n\u003cp\u003eLearn how to perform CV measurements with the Ossila potentiostat.\u003c\/p\u003e\n\u003ca href=\"\/pages\/how-to-perform-cyclic-voltammetry-on-a-polymer-using-a-potentiostat\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/cyclic-voltammetry-troubleshooting\"\u003e\u003cimg alt=\"Troubleshooting Cyclic Voltammetry and Voltammograms\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/electrochemical-cell-lab.jpg?v=1644923395\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=158\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/cyclic-voltammetry-troubleshooting\"\u003eTroubleshooting Cyclic Voltammetry\u003c\/a\u003e\n\u003cp\u003eProblems with cyclic voltammetry are often caused by relatively small mistakes. There are several different ways to troubleshoot the issues, depending on the problem.\u003c\/p\u003e\n\u003ca href=\"\/pages\/cyclic-voltammetry-troubleshooting\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"None \/ Type A (US)","offer_id":31593513615456,"sku":"T2006A1-US","price":1400.0,"currency_code":"GBP","in_stock":true},{"title":"None \/ Type F (EU)","offer_id":31593513680992,"sku":"T2006A1-EU","price":1400.0,"currency_code":"GBP","in_stock":true},{"title":"None \/ Type G (UK)","offer_id":31593513648224,"sku":"T2006A1-UK","price":1400.0,"currency_code":"GBP","in_stock":true},{"title":"None \/ Type I (AU)","offer_id":31593513713760,"sku":"T2006A1-AU","price":1400.0,"currency_code":"GBP","in_stock":true},{"title":"Complete Kit (Non-Aqueous Reference Electrode) \/ Type A (US)","offer_id":31593513484384,"sku":"T2006B1-US","price":1800.0,"currency_code":"GBP","in_stock":true},{"title":"Complete Kit (Non-Aqueous Reference Electrode) \/ Type F (EU)","offer_id":31593513549920,"sku":"T2006B1-EU","price":1800.0,"currency_code":"GBP","in_stock":true},{"title":"Complete Kit (Non-Aqueous Reference Electrode) \/ Type G (UK)","offer_id":31593513517152,"sku":"T2006B1-UK","price":1800.0,"currency_code":"GBP","in_stock":true},{"title":"Complete Kit (Non-Aqueous Reference Electrode) \/ Type I (AU)","offer_id":31593513582688,"sku":"T2006B1-AU","price":1800.0,"currency_code":"GBP","in_stock":true},{"title":"Complete Kit (Aqueous Reference Electrode) \/ Type A (US)","offer_id":43648153780440,"sku":"T2006C1-US","price":1800.0,"currency_code":"GBP","in_stock":true},{"title":"Complete Kit (Aqueous Reference Electrode) \/ Type F (EU)","offer_id":43648153747672,"sku":"T2006C1-EU","price":1800.0,"currency_code":"GBP","in_stock":true},{"title":"Complete Kit (Aqueous Reference Electrode) \/ Type G (UK)","offer_id":43648153714904,"sku":"T2006C1-UK","price":1800.0,"currency_code":"GBP","in_stock":true},{"title":"Complete Kit (Aqueous Reference Electrode) \/ Type I (AU)","offer_id":43648153813208,"sku":"T2006C1-AU","price":1800.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/potentionstat-product-image.jpg?v=1768818808"},{"product_id":"2d-material-fet-substrates","title":"Platinum FET Test Chips, Optimized for 2D Materials","description":"\u003ch2 id=\"product-oneliner\"\u003ePlatinum FET Test Chips\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003e\u003cspan\u003eperform electrical and optical measurements on monolayer or few-layer 2-dimensional (2D) crystals\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eOssila’s 2D material FET test chip is designed to allow users to perform electrical and optical measurements on monolayer or few-layer 2-dimensional (2D) crystals, without the need for expensive lithography equipment. Our chips come prepatterned with platinum electrodes on a Si-SiO2 substrate, with source-drain channel lengths ranging from 4 µm to 20 µm. Transfer your crystal across the channel and you are ready to measure. The chips also feature dual channel electrodes that allow you to stack two crystals on top of each other and contact each separately.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eResearch into 2D materials has been steadily growing in popularity for several years, fuelled by the promise of revolutionary new technology in areas ranging from batteries to quantum computers. The preferred method for 2D material preparation (within the research community at least) is the so-called 'Scotch-tape' method, where monolayer or few-layer crystals are peeled from bulk material. This method currently gives the highest quality 2D materials needed for optical and electronic applications. The preparation of 2D materials in this way is relatively straightforward, and optical measurements can require little more than a microscope and a light source.\u003c\/p\u003e\n\u003cp\u003eHowever, to reach their full potential, the electrical characteristics of 2D materials needs to be studied. This posses a large barrier to entry for the researcher, as complicated and expensive lithography equipment is required to create the electrical contacts to the 2D crystals. We have developed our 2D material FET substrates in partnership with researchers in the field to remove this barrier, and to speed up the electrical and optical characterization of 2D materials.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\n\u003ch2 id=\"characterization\"\u003eCharacterization\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure class=\"double-float-left\"\u003e\u003cimg width=\"230\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/fet-1.jpg?width=230\u0026amp;height=230\" loading=\"lazy\" height=\"230\" alt=\"Characterization\"\u003e\n\u003c\/figure\u003e\n\n\u003cfigure class=\"double-float-right\"\u003e\u003cimg width=\"394\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/fet-1-3d.jpg?width=394\u0026amp;height=250\" loading=\"lazy\" height=\"250\" alt=\"Characterization\"\u003e\n\u003c\/figure\u003e\n\n\n\u003ch2 id=\"specification\"\u003eSpecification\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\"\u003eSubstrate \/ Gate\u003c\/td\u003e\n\u003ctd width=\"75%\"\u003eSilicon (n-doped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate resistivity\u003c\/td\u003e\n\u003ctd\u003e~5 Ωcm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate dielectric\u003c\/td\u003e\n\u003ctd\u003e300 nm thermally grown silicon dioxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14.97 mm x 14.97 mm x 0.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode pad pitch\u003c\/td\u003e\n\u003ctd\u003e1.27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode width\u003c\/td\u003e\n\u003ctd\u003e4 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode material\u003c\/td\u003e\n\u003ctd\u003ePlatinum (50 nm ± 10 nm) \/ Titanium adhesion layer (5 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeposition method\u003c\/td\u003e\n\u003ctd\u003ePlasma sputtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatterning method\u003c\/td\u003e\n\u003ctd\u003ePhotolithography\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel lengths\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4 µm \u003cem\u003e(2x)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e10 µm \u003cem\u003e(2x)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e4 µm x 10 µm\u003c\/p\u003e\n\u003cp\u003e4 µm x\u003cem\u003e \u003c\/em\u003e20 µm\u003c\/p\u003e\n\u003cp\u003e10 µm x 20 µm\u003c\/p\u003e\n\u003cp\u003e10 µm x 20 µm\u003c\/p\u003e\n\u003cp\u003evariable length \u003cem\u003e(x4)\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\n\u003cdiv class=\"expandable\" id=\"view-specifications\"\u003e\n\u003ch4\u003eElectrode layout\u003c\/h4\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-test-chip-schematic.png?v=1575553474\" rel=\"noreffer\" target=\"_blank\" title=\"2d-test-chip-electrodes\"\u003e \u003cimg alt=\"2D material FET test chip electrode layout\" height=\"360\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-test-chip-schematic.png?v=1575553474\u0026amp;width=480\u0026amp;height=360\" width=\"480\"\u003e \u003c\/a\u003e\n\u003cfigcaption\u003eElectrode layout on 2D material FET material test chips\u003cstrong\u003e (click to enlarge) \u003c\/strong\u003e\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe platinum is sputtered onto a titanium adhesion layer to provide an extremely robust contact and channel allowing it to withstand cleaning procedures such as solvent sonication, plasma etching, and swabbing.\u003c\/p\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-ofet-substrate-topography_2048x2048.png?v=1576851946\" rel=\"noreffer\" target=\"_blank\" title=\"2d-test-chip-electrode_topography\"\u003e \u003cimg alt=\"2D material FET test chip electrode topography\" height=\"272\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-ofet-substrate-topography.png?v=1576851946\u0026amp;width=480\u0026amp;height=272\" width=\"480\"\u003e \u003c\/a\u003e\n\u003cfigcaption\u003eSurface topography of a dual-electrode pair\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eElectrical measurements on small 2D crystals can be tricky. It usually involves a multistage process consisting of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExfoliation of a bulk crystal into a 2d flakes\u003c\/li\u003e\n\u003cli\u003eLocating a suitable flake\u003c\/li\u003e\n\u003cli\u003eTransfer of the flake onto a substrate\u003c\/li\u003e\n\u003cli\u003eDesigning electrodes around the flake\u003c\/li\u003e\n\u003cli\u003ePatterning of electrodes, usually using ebeam lithography\u003c\/li\u003e\n\u003cli\u003eMetal deposition and lift-off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Ossila test chips optimized for 2D materials help simplify this workflow by providing pre-patterned platinum electrodes onto which a flake can be directly transferred. This eliminates the need for access to lithography and deposition systems.\u003c\/p\u003e\n\u003cp\u003eThe electrode contacts are placed along the edges of the test chip, allowing optical measurements to be carried out without obstruction from wires.\u003c\/p\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-ofet-substrate-electrode-examples_2048x2048.png?v=1575653185\" rel=\"noreffer\" target=\"_blank\" title=\"2d-test-chip-flakes-examples\"\u003e \u003cimg alt=\"2D material FET test chip flakes examples\" height=\"231\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-ofet-substrate-electrode-examples.png?v=1575653185\u0026amp;width=480\u0026amp;height=231\" width=\"480\"\u003e \u003c\/a\u003e\n\u003cfigcaption\u003eLeft: Depiction of a 2D flake spanning a variable gap channel. The position of the flake determines the channel width. Right: Two 2D flakes arranged on dual-pair electrodes\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCleaning\u003c\/h4\u003e\n\u003cp\u003eYour substrates may arrive with a residue from the photolithography process used to create the electrodes. We recommend cleaning the substrates before use by sonication in warm isopropanol for 10 minutes, followed by drying with compressed nitrogen. The substrates may be cleaned and reused as needed.\u003c\/p\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-ofet-substrate-cleaning_2048x2048.png?v=1575633314\" rel=\"noreffer\" target=\"_blank\" title=\"2d-test-chip-cleaning\"\u003e \u003cimg alt=\"2D material FET test chip cleaning\" height=\"200\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-ofet-substrate-cleaning.png?v=1575633314\u0026amp;crop=center\u0026amp;width=480\u0026amp;height=200\" width=\"480\"\u003e \u003c\/a\u003e\n\u003cfigcaption\u003eElectrode pair before (left) and after (right) sonication in warm isopropanol for 5 minutes\u003cstrong\u003e (click to enlarge) \u003c\/strong\u003e\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eSample preparation\u003c\/h4\u003e\n\u003cp\u003eOur guide to 2D exfoliation will walk you through the process preparing a suitable crystal for transfer, and deterministically positioning a flake on a substrate.\u003c\/p\u003e\n\u003ch4\u003eElectrical connections\u003c\/h4\u003e\n\u003cp\u003eThe 32 rectangular pads are source-drain contacts. Once a flake has been positioned across the channel, the pads connected to electrodes on each side of the channel should be identified and a voltage applied across them. There are 3 different electrode geometries on the chip:\u003cbr\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDual electrodes in an inline configuration with fixed channel width (4 µm and 10 µm)\u003c\/li\u003e\n\u003cli\u003eQuad electrodes in cross configuration with fixed channel widths (4 µm x 10 µm, 4 µm x 20 µm, 10 µm x 20 µm and 10 µm x 40 µm)\u003c\/li\u003e\n\u003cli\u003eDual electrodes in a perpendicular configuration which allows the channel width to be defined by the size of the crystal\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-ofet-substrate-electrodes_2048x2048.png?v=1575638318\" rel=\"noreffer\" target=\"_blank\" title=\"2d-test-chip-electrodes\"\u003e \u003cimg alt=\"2D material FET test chip electrodes\" height=\"386\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-ofet-substrate-electrodes.png?v=1575638318\u0026amp;width=480\u0026amp;height=386\" width=\"480\"\u003e \u003c\/a\u003e\n\u003cfigcaption\u003eMicroscope images of some of the electrodes on the 2D material test chip\u003cstrong\u003e (click to enlarge) \u003c\/strong\u003e\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eA probe station can be used to connect to the pads. Alternatively, a wire can be attached using conductive silver paint.\u003c\/p\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-fet-silver-paint-wire_2048x2048.jpg?v=1576506908\" rel=\"noreffer\" target=\"_blank\" title=\"2d-test-chip-electrical-connection\"\u003e \u003cimg alt=\"2D material FET test chip electrical connection\" height=\"343\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-fet-silver-paint-wire.jpg?v=1576506908\u0026amp;width=379\u0026amp;height=343\" width=\"379\"\u003e \u003c\/a\u003e\n\u003cfigcaption\u003eA wire attached to an electrode pad with conductive silver paint\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe gate can be contacted directly through the substrate bottom or edges, or the 4 corner pads can act as the gate contact. If using the corner pads, we recommend applying silver (conductive) paint along and around the pad edges to make a connection with the substrate edge.\u003c\/p\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-fet-gate-connection.png?v=1578586352\" rel=\"noreffer\" target=\"_blank\" title=\"2d-test-chip-gate-connection\"\u003e \u003cimg alt=\"2D material FET test chip gate connection\" height=\"263\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2d-fet-gate-connection.png?v=1578586352\u0026amp;width=480\u0026amp;height=263\" width=\"480\"\u003e \u003c\/a\u003e\n\u003cfigcaption\u003eConductive silver paint applied to connect a gate pad to the substrate edge\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eOver time a native oxide layer of a few nanometers thickness will build up on the exposed silicon. Removing this will allow a lower resistance electrical connection to the gate. If required, we recommend removing the native oxide mechanically by using a fine grit sandpaper or scratching the silicon area before making the contact. We do not recommend chemical removal of the native oxide as this process may damage the platinum electrodes and gate dielectric.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbutton class=\"anchor expand-link\" data-expand-target=\"view-specifications\" data-toggle-text=\"Hide\" type=\"button\"\u003eView specifications\u003c\/button\u003e\u003c\/p\u003e\n","brand":"Ossila","offers":[{"title":"Default Title","offer_id":31461339267168,"sku":"S0420A1","price":200.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/platinum-fet-test-chips.png?v=1768384049"},{"product_id":"solar-simulator-iv-test-system-bundle","title":"Automated Solar Cell Testing Kit","description":"\u003ch2 id=\"product-oneliner\"\u003eAll-in-One Solution for Simple Solar Cell Characterization\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eIntegrated test system and solar simulator with a reference solar cell and user-friendly software\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#software\"\u003eSoftware\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#included\"\u003eIn the Box\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eSimplify solar cell testing with a complete and integrated system. For rapid and reliable performance data, the system automatically switches between pixels and calculates key device metrics.\u003c\/p\u003e\n\u003cp\u003eThe I–V test system works seamlessly with the LED lamp to provide accurate current–voltage curves, excellent spectral match, and superb spatial and temporal uniformity. Use the software to control the light source and manage the I–V test system according to your characterization requirements. With minimal lamp warm-up time, you can plug in the system, install the software, and start testing straight away.\u003c\/p\u003e\n\u003cdiv class=\"left-accent-panel teal-blue-accent\"\u003eAll of the Ossila Solar Cell Testing Kits come with our Reference Solar Cell included. This allows you to monitor and track the performance of the solar simulator, confirming consistent performance.\u003c\/div\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Powerful_Electronics-05.svg\" loading=\"lazy\" height=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eSimple Characterization\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eWith automatic pixel switching\u003cbr\u003eand free intuitive software\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 margin-top text-center\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Linear_Stage_Icons_Built-to-last.svg\" loading=\"lazy\" height=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eMeasure Device Stability\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eTrack key device properties over repeated current-voltage measurements\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spectral-tunability-icon.svg?v=1718794539\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eCustomize the Spectral Output\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eIndividual LED power control\u003cbr\u003eacross 350 nm – 1000 nm\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Large_Range_of_Speeds.svg\" loading=\"lazy\" height=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eWide Measurement Range\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eHigh-res voltages from -10 to +10 V and measurement of ±10 nA to ±200 mA\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003ch2\u003eWhat is Automatic Pixel Switching?\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eWhen you fabricate solar cells, you may create several individual cells on a single substrate. At Ossila, we call these individual cells pixels, and we refer to the full substrate as a device. For example, if you use our 25 mm square multi-electrode deposition mask (E2001A1) with a 25 mm ITO glass substrate (S2006C1), you will produce four separate solar cells on a single substrate. This gives you a device with four pixels.\u003c\/p\u003e\n\u003cp\u003eAutomatic pixel switching connects to each pixel on your device, without manual reconfiguration, to speed up your measurements and enable lifetime metric tracking for multiple pixels.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"specification\"\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eSolar Simulator\u003c\/h3\u003e\n\u003cp\u003eThe improved solar simulator has slightly increased spectral coverage across the visible spectrum, and reduced spectral deviation compared to previous versions, while still maintaining 1 Sun Irradiance between 380 – 1000 nm.\u003c\/p\u003e\n\u003cp\u003eWhile both version solar simulators achieve AAA classification over a 15 mm area, the new solar simulator (released January 2026) has a marginally improved spectral match. Previous classification graphs (for Solar Simulators purchased before 2025) can be found on our \u003ca href=\"https:\/\/www.ossila.com\/pages\/ossila-solar-simulator-classification-data\"\u003eClassification Data\u003c\/a\u003e page.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpectral Match\u003c\/th\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpatial Uniformity (over 15 mm diameter area)\u003c\/th\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpatial Uniformity(over 25 mm diameter area)\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpatial Uniformity (over 32 mm diameter area)\u003c\/th\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eTemporal Instability\u003c\/th\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/solar-simulator-v3-spectrum.svg\"\u003e\u003cimg alt=\"Spectral irradiance graph\" height=\"306.53\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/solar-simulator-v3-spectrum.svg\" width=\"600\"\u003e\u003c\/a\u003e\n\u003cfigcaption\u003eRepresentative spectral irradiance graph measured at 1000 W\/m\u003csup\u003e2\u003c\/sup\u003e (1 Sun)\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLED-based, steady-state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpectral Deviation\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;70%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpectral Coverage\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWorking Distance\u003c\/th\u003e\n\u003ctd\u003e8.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eIrradiance*\u003c\/th\u003e\n\u003ctd\u003e1000 W\/m\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Lamp Time\u003c\/th\u003e\n\u003ctd\u003e10000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e* +\/- 5% at working distance and calibration temperature.\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 15px;\" class=\"left-accent-panel ossila-blue-accent\"\u003ePlease see the \u003cstrong\u003e\u003ca title=\"Standalone LED solar simulator lamp\" href=\"\/products\/solar-simulator-lamp#classification\"\u003eLED Solar Simulator Lamp\u003c\/a\u003e\u003c\/strong\u003e product page for full specifications.\u003c\/div\u003e\n\u003cfigure\u003e\u003cimg width=\"636\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/solar-simulator-testing-kit-wireframe.svg\" loading=\"lazy\" height=\"438.75\" alt=\"Ossila Automated Solar Cell Testing Kit\"\u003e\u003c\/figure\u003e\n\u003ch3\u003eSolar Cell I-V Test System\u003c\/h3\u003e\n\u003ch4\u003eVoltage Source\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eRange\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eAccuracy\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003ePrecision\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eResolution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e± 10 V\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e10 mV\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e333 µV\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e170 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eVoltage Measure\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eRange\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eAccuracy\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003ePrecision\u003c\/th\u003e\n\u003cth width=\"25%\" class=\"text-center\"\u003eResolution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e± 10V\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e10 mV\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e50 µV\u003c\/td\u003e\n\u003ctd width=\"25%\" class=\"text-center\"\u003e10 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCurrent Measure\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"20%\" class=\"text-center\"\u003eRange\u003c\/th\u003e\n\u003cth width=\"20%\" class=\"text-center\"\u003eAccuracy\u003c\/th\u003e\n\u003cth width=\"20%\" class=\"text-center\"\u003ePrecision\u003c\/th\u003e\n\u003cth width=\"20%\" class=\"text-center\"\u003eResolution\u003c\/th\u003e\n\u003cth width=\"20%\" class=\"text-center\"\u003eBurden\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e± 200 mA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e± 500 \u003cspan\u003eµ\u003c\/span\u003eA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e10 µA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e1 µA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e\u0026lt;20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e± 20 mA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e± 10 µA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e1 µA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e100 nA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e\u0026lt;20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e± 2 mA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e± 1 µA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e100 nA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e10 nA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e\u0026lt;20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e± 200 µA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e± 100 nA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e10 nA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e1 nA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e\u0026lt;20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e± 20 µA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e± 10 nA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e1 nA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e0.1nA\u003c\/td\u003e\n\u003ctd width=\"20%\" class=\"text-center\"\u003e\u0026lt;20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEquipment Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCompatible Substrates\u003c\/th\u003e\n\u003ctd\u003e\n\u003ca title=\"20 mm x 15 mm PV substrates\" href=\"https:\/\/www.ossila.com\/products\/pv-substrates\"\u003eS211\u003c\/a\u003e (T3003B4)\u003cbr\u003e\u003ca title=\"25 mm x 25 mm PV substrates\" href=\"https:\/\/www.ossila.com\/products\/ito-glass-substrates-pv-oled-25mm-square\"\u003eS2006C1\u003c\/a\u003e (T3003E4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eLamp Dimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e105 mm x 90 mm x 80 mm (4.31\" x 3.54\" x 3.15\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eI-V Test System Dimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e150 mm x 55 mm x 300 mm (5.91\" x 2.17\" x 11.81\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"software\"\u003eSoftware\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eSolar Cell I-V\u003c\/h3\u003e\n\u003cfigure\u003e\u003cimg alt=\"Solar Cell I-V Software\" height=\"447\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/software-solar-cell-iv-measurement.png?v=1660745395\" width=\"826\"\u003e\n\u003cfigcaption\u003eRapid device characterization with the Ossila Solar Cell I-V software\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eWith the PC software, you can:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ePerform current-voltage measurements anywhere between -10 V and 10 V.\u003c\/li\u003e\n\u003cli\u003eTake high resolution measurements, with voltage increments as low as 170 µV.\u003c\/li\u003e\n\u003cli\u003eManage the experiment more directly, with custom settle times between applying voltage and measuring current.\u003c\/li\u003e\n\u003cli\u003eMeasure device hysteresis by perform consecutive measurements in forwards and backward directions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe software has 4 measurement tabs: Solar Cell Characterization, Stabilized Current Output, Solar Lifetime Measurement and Maximum Power Point Tracking. 'Characterization' performs I-V measurements and calculates the important device properties, the 'Stabilized Current' tab allows you to determine how the current output of your device evolves over time using, and the 'Lifetime' tab enables you to track key device properties (PCE, FF, J\u003csub\u003esc\u003c\/sub\u003e, V\u003csub\u003eoc\u003c\/sub\u003e) over an extended time by performing periodic I-V characterization. Between measurements the solar cell can be held at open-circuit, short-circuit, or maximum power. The 'Maximum Power Point' tab tracks the maximum power point over time, as well as the current density J\u003csub\u003emp\u003c\/sub\u003e and operating voltage V\u003csub\u003emp\u003c\/sub\u003e.\u003c\/p\u003e\n\u003ch4 class=\"padding-top\"\u003eSoftware Requirements\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eOperating System\u003c\/th\u003e\n\u003ctd\u003eWindows 11 (64-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCPU\u003c\/th\u003e\n\u003ctd\u003eDual Core 2 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eRAM\u003c\/th\u003e\n\u003ctd\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAvailable Hard Drive Space\u003c\/th\u003e\n\u003ctd\u003e233 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMonitor Resolution\u003c\/th\u003e\n\u003ctd\u003e1680 x 1050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003eUSB 2.0, or Ethernet (requires DHCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSolar Simulator Console\u003c\/h3\u003e\n\u003cp class=\"padding-bottom\"\u003eControl and customize the output of your LED solar simulator. You can choose the overall power level or control each LED individually to tailor the output to your specific requirements. The user-friendly software can be installed on as many PCs as you want and you can access future updates for free.\u003c\/p\u003e\n\u003cfigure class=\"double-float-left\"\u003e\u003cimg alt=\"Solar Simulator Console software (light mode)\" height=\"520\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/solar-simulator-console-2-light.png\" width=\"470\"\u003e\n\u003cfigcaption\u003eSoftware in light mode\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cfigure class=\"double-float-right\"\u003e\u003cimg alt=\"Solar Simulator Console software (dark mode)\" height=\"520\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/solar-simulator-console-2-dark.png\" width=\"470\"\u003e\n\u003cfigcaption\u003eSoftware in dark mode\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eSoftware Requirements\u003c\/h4\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eOperating System\u003c\/th\u003e\n\u003ctd\u003eWindows 11 (64-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCPU\u003c\/th\u003e\n\u003ctd\u003eDual Core 2 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eRAM\u003c\/th\u003e\n\u003ctd\u003e4 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAvailable Hard Drive Space\u003c\/th\u003e\n\u003ctd\u003e152 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMonitor Resolution\u003c\/th\u003e\n\u003ctd\u003e1440 x 960\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eConnectivity\u003c\/th\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cvideo width=\"848.328\" title=\"How to use the Ossila Solar Simulator Software\" preload=\"none\" poster=\"https:\/\/cdn.ossila.com\/videos\/solar-simulator-software-demo.jpg\" height=\"477.172\" crossorigin=\"\" controlslist=\"nodownload\" controls=\"controls\" class=\"widescreen\"\u003e\n        \u003csource type=\"video\/mp4\" src=\"https:\/\/cdn.ossila.com\/videos\/solar-simulator-software-demo.mp4\"\u003e\n        \u003ctrack srclang=\"en\" src=\"https:\/\/cdn.ossila.com\/videos\/solar-simulator-software-demo.vtt\" label=\"English\" kind=\"subtitles\" default=\"\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"How to use the Ossila Solar Simulator Software\",\n\"description\": \"How to use the Ossila Solar Simulator Software\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/solar-simulator-software-demo.jpg\",\n\"uploadDate\": \"2025-09-15\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/solar-simulator-software-demo.mp4\",\n\"duration\": \"PT1M41S\"\n}\n\u003c\/script\u003e\n\u003cfigcaption\u003eHow to use the Ossila Solar Simulator Software\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch2 id=\"features\"\u003eAll-in-One Characterization\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg class=\"img-round\" width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Solar-Cell-Testing-Kit-Automated.jpg?width=112\u0026amp;height=112\u0026amp;crop=center\" loading=\"lazy\" height=\"112\" alt=\"Complete solar cell testing kit\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eComprehensive Solar Cell Measurements\u003c\/p\u003e\n\u003cp\u003eEverything you need for reliable photovoltaic characterization. Perform I-V sweeps to find key device performance metrics, run lifetime measurements for degradation studies, or use as a soaking system to precondition cells. Streamline the measurement process and eliminate manual steps as the system automatically switches between pixels and records the temperature and light conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"High power LED lamp\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/LED_Lamp.jpg?v=1720698557\u0026amp;crop=center\u0026amp;width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eSource Reliable, Calibrated Light\u003c\/p\u003e\n\u003cp\u003eReliably and accurately mimic the solar spectrum in your photovoltaic research with a calibrated array of light emitting diodes. The simple setup makes it easy to integrate the system into your workflow while keeping your measurements stable and repeatable. Alongside a long lifetime and good temporal stability, the solar simulator also boasts low running costs, zero maintenance, and no explosion risk.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg class=\"img-round\" width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/solar-simulator-console-software.png?v=1675353294\u0026amp;crop=center\u0026amp;width=112\u0026amp;height=112\" loading=\"lazy\" height=\"112\" alt=\"Compact for custom setups\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eAdapt the Spectral Output\u003c\/p\u003e\n\u003cp\u003eChange the total irradiance output or control the power output of each LED individually. With the flexibility of a tunable spectrum, you can align your testing with specific lighting spectrum conditions. This solar simulator can also be calibrated to test indoor photovoltaics according to newly defined standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eAutomated Solar Cell Testing Kit Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca title=\"Solar Cell Testing Kit Light Source\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Solar-Cell-Testing-Kit-Light-Source.jpg?width=1620\"\u003e \u003cimg alt=\"Solar Cell Testing Kit Light Source\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Solar-Cell-Testing-Kit-Light-Source.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca title=\"Automated Ossila Solar Cell Testing Kit set up\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Automated-Ossila-Solar-Cell-Testing-Kit-set-up.jpg?width=1620\"\u003e \u003cimg alt=\"Automated Ossila Solar Cell Testing Kit set up\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Automated-Ossila-Solar-Cell-Testing-Kit-set-up.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" title=\"Ossila Automated Solar Cell Testing Kit\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Solar-Cell-Testing-Kit-Automated.jpg?width=1620\"\u003e \u003cimg alt=\"Ossila Automated Solar Cell Testing Kit\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Solar-Cell-Testing-Kit-Automated.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca title=\"Solar Cell Testing Kit in the lab\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Solar-Cell-Testing-Kit-set-up.jpg?width=1620\"\u003e \u003cimg alt=\"Solar Cell Testing Kit in the lab\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Solar-Cell-Testing-Kit-set-up.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca title=\"LED lamp\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-Automated-Solar-Cell-Testing-Kit.jpg?width=1620\"\u003e \u003cimg alt=\"LED lamp\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-Automated-Solar-Cell-Testing-Kit.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca role=\"button\" class=\"carousel-left-control\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-left\"\u003e\n            \u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\n        \u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious\u003c\/span\u003e \u003c\/a\u003e \u003ca role=\"button\" class=\"carousel-right-control\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-right\"\u003e\n            \u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\n        \u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"included\"\u003eIn the Box\u003c\/h2\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eLED solar simulator lamp\u003c\/li\u003e\n\u003cli\u003eAutomated solar cell I-V test system\u003c\/li\u003e\n\u003cli\u003eFixed bracket\u003c\/li\u003e\n\u003cli\u003eTest board\u003c\/li\u003e\n\u003cli\u003eReference solar cell\u003c\/li\u003e\n\u003cli\u003eUSB Driver with calibration certificate \u0026amp; QC test data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/automated-solar-simulator-assembly\"\u003e\u003cimg src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Solar_Simulator_IV_Test_System_20x15mm_WHITE_LIGHT_-_Product_Photo.jpg?crop=center\u0026amp;width=160\u0026amp;height=160\" loading=\"lazy\" height=\"160\" alt=\"How to Assemble the Automated Solar Cell Testing Kit\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/automated-solar-simulator-assembly\"\u003eHow to Assemble the Automated Solar Cell Testing Kit\u003c\/a\u003e\n\u003cp\u003eThe automated Ossila Solar Cell Testing Kit allows you to set up your solar cell testing lab quickly and easily. The system is designed to be easy to use and effortless to assemble.\u003c\/p\u003e\n\u003ca href=\"\/pages\/automated-solar-simulator-assembly\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/solar-cells-low-device-metrics\"\u003e\u003cimg src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/J-V-curve-place-device-in-board.jpg?v=1685518690\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\" loading=\"lazy\" height=\"160\" alt=\"Analyzing and Improving Low Device Metrics: FF, VOC and JSC\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/solar-cells-low-device-metrics\"\u003e Analyzing and Improving Low Device Metrics: FF, V\u003csub\u003eOC\u003c\/sub\u003e and J\u003csub\u003eSC\u003c\/sub\u003e \u003c\/a\u003e\n\u003cp\u003eAnaylzing key device metrics such as fill factor (FF), open-circuit voltage (V\u003csub\u003eOC\u003c\/sub\u003e), and power conversion efficiency (PCE), can help you find potential issues with your solar cell devices\u003c\/p\u003e\n\u003ca href=\"\/pages\/solar-cells-low-device-metrics\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"For 20 mm x 15 mm Ossila substrates \/ Solar testing kit only","offer_id":43491053338840,"sku":"T3003B4","price":4300.0,"currency_code":"GBP","in_stock":true},{"title":"For 20 mm x 15 mm Ossila substrates \/ Testing kit + filter for indoor simulation","offer_id":45057063190744,"sku":"T3003B4-GA1","price":4600.0,"currency_code":"GBP","in_stock":true},{"title":"For 25 mm x 25 mm Ossila substrates \/ Solar testing kit only","offer_id":43491053371608,"sku":"T3003E4","price":4300.0,"currency_code":"GBP","in_stock":true},{"title":"For 25 mm x 25 mm Ossila substrates \/ Testing kit + filter for indoor simulation","offer_id":45057063223512,"sku":"T3003E4-GA1","price":4600.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/solar-cell-testing-kit-product-photo.jpg?v=1767691138"},{"product_id":"automatic-film-applicator","title":"Automatic Film Applicator","description":"\u003ch2 id=\"product-oneliner\"\u003e\u003cspan\u003eAutomate Your Coating Processes for Larger Substrates\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003ePair with a range of applicators for bar coating, doctor blade coating, and more\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#included\"\u003eIn the Box\u003c\/a\u003e | \u003ca href=\"#accessories\"\u003eApplicators and Accessories\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eThis adaptable coating system automates the movement of your chosen applicator, from Mayer bars, blade coaters, and gap applicators, to Sheen, Baker, or Bird applicators. Set the optimal speed, from 0.05 mm.s\u003csup\u003e-1\u003c\/sup\u003e to 250 mm.s\u003csup\u003e-1\u003c\/sup\u003e, for your applicator and solution consistency to create uniform coatings across a large area. Choose between a simple glass stage for easy cleaning or a vacuum stage to securely hold your substrate in place (with or without compatible Diaphragm Vacuum Pump).\u003c\/p\u003e\n\u003cp\u003eMix and match the automatic system with our interchangeable applicators or opt for one of our complete coating kits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Ossila \u003ca href=\"https:\/\/www.ossila.com\/products\/bar-coater\"\u003eBar Coater\u003c\/a\u003e includes a set of compatible Mayer rods for coating thicknesses from 6 µm to 200 µm.\u003c\/li\u003e\n\u003cli\u003eThe Ossila \u003ca href=\"https:\/\/www.ossila.com\/products\/doctor-blade-coater\"\u003eDoctor Blade Coater\u003c\/a\u003e enables micron-level thickness adjustments with a single applicator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Linear_Stage_Icons_Improved-Reapeatability.svg?v=1697630031\" loading=\"lazy\" height=\"50\" alt=\"Repeatable and customizable coatings\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eRepeatable Coatings\u003cbr\u003eMade Simple\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eProgram consistent speeds to standardize your coatings\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"42\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Wide_Working_Space.svg?v=1697622912\" loading=\"lazy\" height=\"42\" class=\"margin-bottom\" alt=\"Uniform films over a large area\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eUniform Coatings on\u003cbr\u003ea Range of Substrates\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eUp to 225 mm coating widths across\u003cbr\u003ea 290 mm travel distance\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2D-Materials-Icons_-Different_Forms.svg?v=1718707762\" loading=\"lazy\" height=\"50\" alt=\"Versatile automatic film applicator design\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eSwitch Between a Wide\u003cbr\u003eRange of Applicators\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eExperiment with different coating techniques with one system\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Quick_release_or_Speed.svg?v=1697701268\" loading=\"lazy\" height=\"50\" alt=\"Set up your automatic film applicator quickly\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eEfficient Setup with\u003cbr\u003eQuick Lock Design\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eEasy stage and drip tray cleaning between different coatings\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure\u003e\u003cvideo width=\"848.328\" title=\"Automatic Film Applicator Product Overview video\" preload=\"none\" poster=\"https:\/\/cdn.ossila.com\/videos\/automatic-film-applicator-product-overview.jpg\" height=\"477.172\" crossorigin=\"\" controlslist=\"nodownload\" controls=\"controls\" class=\"widescreen\"\u003e\n\u003csource type=\"video\/mp4\" src=\"https:\/\/cdn.ossila.com\/videos\/automatic-film-applicator-product-overview.mp4\"\u003e\n\u003ctrack srclang=\"en\" src=\"https:\/\/cdn.ossila.com\/videos\/automatic-film-applicator-product-overview.vtt\" label=\"English\" kind=\"subtitles\" default=\"\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"Ossila Automatic Film Applicator Product Overview\",\n\"description\": \"Ossila Automatic Film Applicator Product Overview\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/automatic-film-applicator-product-overview.jpg\",\n\"uploadDate\": \"2025-02-12\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/automatic-film-applicator-product-overview.mp4\",\n\"duration\": \"PT0M55S\"\n}\n\u003c\/script\u003e\u003c\/figure\u003e\n\u003ch2 id=\"specification\"\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Stage Travel Length\u003c\/th\u003e\n\u003ctd\u003e290 mm (A4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMinimum Stage Speed\u003c\/th\u003e\n\u003ctd\u003e0.05 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Stage Speed\u003c\/th\u003e\n\u003ctd\u003e250 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eStage Speed Increments\u003c\/th\u003e\n\u003ctd\u003e0.01 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVacuum Stage\u003c\/th\u003e\n\u003ctd\u003eAnodized aluminum stage, 0.8 mm vacuum holes, square grid arrangement (7.75 mm spacing), 6 mm push-fit connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass Stage\u003c\/th\u003e\n\u003ctd\u003e8 mm toughened glass, printed grid pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Coating Width\u003c\/th\u003e\n\u003ctd\u003e225 mm (accommodates Mayer bars with a 255 mm coating width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMinimum Mayer Bar Length\u003c\/th\u003e\n\u003ctd\u003e220 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eDC 24 V, 2 A, via 100 – 240 V 50\/60 Hz power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDimensions (D x W x H)\u003c\/th\u003e\n\u003ctd\u003e360 mm x 280 mm x 190 mm (14.2\" x 11\" x 7.5\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e6.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg width=\"636\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automated-thin-film-applicator-wire-frame.svg?v=1734600279\" loading=\"lazy\" height=\"438.75\" alt=\"Ossila Automatic Film Applicator Wireframe\"\u003e\u003c\/figure\u003e\n\u003ch2 id=\"features\"\u003eAutomate Your Coating Processes\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Processing_icons_Stainless_steel_tray.svg?v=1697616401\" loading=\"lazy\" height=\"112\" alt=\"Intuitive system design\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\" style=\"padding-top: 10px;\"\u003eIntuitive and Simple Coatings\u003c\/p\u003e\n\u003cp\u003eAchieve smooth, continuous movement across a wide range of speeds, allowing you to coat different solution viscosities without forming defects. With a quick locking magnet, the stage can be removed and reinstalled, or even switched between the glass and vacuum stage, with ease for quick and efficient cleaning between coatings. The drip tray includes the same design so you can clean up excess solution from your system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon-large-coating-area.svg?v=1731401281\" loading=\"lazy\" height=\"112\" alt=\"Large coating area\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\" style=\"padding-top: 10px;\"\u003eVersatile Coating Area\u003c\/p\u003e\n\u003cp\u003ePerfect for coating large area samples up to A4, scaling up your coating processes with a wide range of techniques has never been easier. The automatic film applicator ensures compatibility with different applicator techniques; \u003cspan\u003efrom Mayer bars, blade coaters, and gap applicators, to Sheen, Baker, or Bird applicators\u003c\/span\u003e. Plus, the glass plate stage is pre-printed with a grid pattern so you can quickly setup and align your samples.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Surface_Cleaning.svg\" loading=\"lazy\" height=\"112\" alt=\"Vacuum compatible\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\" style=\"padding-top: 10px;\"\u003eIdeal for Flexible Substrates\u003c\/p\u003e\n\u003cp\u003eIf you are coating flexible substrates, choose the vacuum stage paired with the Ossila Vaccum Pump. With a maximum vacuum of 330 mbar and a 7 L\/min maximum flow rate, it is perfect for securing flexible or foil substrates. The vacuum stage is comes with grid-based design so you can easily define vacuum area to fit your substrate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eAutomatic Film Applicator Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cvideo width=\"848.33\" type=\"video\/mp4\" title=\"Automatic Film Applicator Coating\" src=\"https:\/\/cdn.ossila.com\/videos\/automatic-film-applicator-coating-loop.mp4\" muted=\"muted\" loop=\"loop\" height=\"477.17\" class=\"widescreen\" autoplay=\"autoplay\" alt=\"Automatic Film Applicator Coating\"\u003e\u003c\/video\u003e\u003c\/p\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca title=\"Ossila Automatic Film Applicato\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator.jpg?v=1735648770\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator.jpg?v=1735648770\" loading=\"lazy\" height=\"280\" alt=\"Ossila Automatic Film Applicator\"\u003e \u003c\/a\u003e \u003ca title=\"Automatic Film Applicator Alignment Plate\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-coater-bar-coating.jpg?v=1735648770\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-coater-bar-coating.jpg?v=1735648770\" loading=\"lazy\" height=\"280\" alt=\"Automatic Film Applicator Bar Coating\"\u003e \u003c\/a\u003e \u003ca title=\"Automatic Film Applicator Software\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator-software.jpg?v=1735648772\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator-software.jpg?v=1735648772\" loading=\"lazy\" height=\"280\" alt=\"Automatic Film Applicator With Sheen Applicator\"\u003e \u003c\/a\u003e \u003ca title=\"Automatic Film Applicator For Doctor Blade Coating\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator-doctor-blade-coater.jpg?v=1735648770\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator-doctor-blade-coater.jpg?v=1735648770\" loading=\"lazy\" height=\"280\" alt=\"Automatic Film Applicator For Doctor Blade Coating\"\u003e \u003c\/a\u003e \u003ca title=\"Automatic Film Applicator in use\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator-sheen-applicator.jpg?v=1735648770\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator-sheen-applicator.jpg?v=1735648770\" loading=\"lazy\" height=\"280\" alt=\"Automatic Film Applicator in use\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca role=\"button\" class=\"carousel-left-control\"\u003e \u003csvg class=\"icon icon-chevron-left\" aria-hidden=\"true\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious\u003c\/span\u003e \u003c\/a\u003e \u003ca role=\"button\" class=\"carousel-right-control\"\u003e \u003csvg class=\"icon icon-chevron-right\" aria-hidden=\"true\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp class=\"text-muted\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2 id=\"included\"\u003eIn the Box\u003c\/h2\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eOssila Automatic Film Applicator\u003c\/li\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"accessories\"\u003eApplicators and Accessories\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e[[collection handle=\"equipment-accessories\" tags=\"thin film applicator\"]]\u003c\/p\u003e","brand":"Ossila","offers":[{"title":"Vacuum Bed \/ Type B (US)","offer_id":50422134341848,"sku":"L2009B1-US","price":2700.0,"currency_code":"GBP","in_stock":true},{"title":"Vacuum Bed \/ Type F (EU)","offer_id":50422134374616,"sku":"L2009B1-EU","price":2700.0,"currency_code":"GBP","in_stock":true},{"title":"Vacuum Bed \/ Type G (UK)","offer_id":50422134407384,"sku":"L2009B1-UK","price":2700.0,"currency_code":"GBP","in_stock":true},{"title":"Vacuum Bed \/ Type I (AU)","offer_id":50422134440152,"sku":"L2009B1-AU","price":2700.0,"currency_code":"GBP","in_stock":true},{"title":"Vacuum Bed \/ Type D\/H\/K\/L\/M\/N","offer_id":50422134472920,"sku":"L2009B1","price":2700.0,"currency_code":"GBP","in_stock":false},{"title":"Vacuum Bed + Vacuum Pump \/ Type B (US)","offer_id":51151991734488,"sku":"L2009C1-US","price":3100.0,"currency_code":"GBP","in_stock":true},{"title":"Vacuum Bed + Vacuum Pump \/ Type F (EU)","offer_id":51151992488152,"sku":"L2009C1-EU","price":3100.0,"currency_code":"GBP","in_stock":true},{"title":"Vacuum Bed + Vacuum Pump \/ Type G (UK)","offer_id":51151992389848,"sku":"L2009C1-UK","price":3100.0,"currency_code":"GBP","in_stock":true},{"title":"Vacuum Bed + Vacuum Pump \/ Type I (AU)","offer_id":51151993143512,"sku":"L2009C1-AU","price":3100.0,"currency_code":"GBP","in_stock":true},{"title":"Vacuum Bed + Vacuum Pump \/ Type D\/H\/K\/L\/M\/N","offer_id":51151993209048,"sku":"L2009C1","price":3100.0,"currency_code":"GBP","in_stock":false},{"title":"Glass \/ Type B (US)","offer_id":49825298317528,"sku":"L2009A1-US","price":1950.0,"currency_code":"GBP","in_stock":true},{"title":"Glass \/ Type F (EU)","offer_id":49825298350296,"sku":"L2009A1-EU","price":1950.0,"currency_code":"GBP","in_stock":true},{"title":"Glass \/ Type G (UK)","offer_id":49825298383064,"sku":"L2009A1-UK","price":1950.0,"currency_code":"GBP","in_stock":true},{"title":"Glass \/ Type I (AU)","offer_id":49825298415832,"sku":"L2009A1-AU","price":1950.0,"currency_code":"GBP","in_stock":true},{"title":"Glass \/ Type D\/H\/K\/L\/M\/N","offer_id":49825298448600,"sku":"L2009A1","price":1950.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/automatic-film-applicator-vacuum-bed.jpg?v=1751553526"},{"product_id":"bar-coater","title":"Bar Coater","description":"\u003ch2 id=\"product-oneliner\"\u003eBar Coater Machine with Wire-Wound or Formed Bar Applicators\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eComplete kit with 16 Meyer bars for versatile bar coating at a competitive price\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#bar-coater-thickess\"\u003eBar Coater Thickness\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#process\"\u003eBar Coating Process\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#included\"\u003eIn the Box\u003c\/a\u003e | \u003ca href=\"#resources\"\u003e Resources\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eThe Ossila Bar Coater can standardize your bar coating methods. The Automatic Film Applicator controls bar movement to 0.01 mm.s\u003csup\u003e-1\u003c\/sup\u003e resolution, allowing coating speeds from 0.05 – 250 mm.s\u003csup\u003e-1\u003c\/sup\u003e. With a maximum coating area of 290 x 225 mm, this kit is perfect for laboratory scale film optimization. Choose between a durable glass stage, or a vacuum-bed stage for easily securing flexible or foil substrates in place.\u003c\/p\u003e\n\u003cp\u003eThis bar coating machine comes with 16 compatible Mayer bars, so is capable of producing wet film thicknesses from 6 µm - 200 µm. Available with lower cost wire-wound bars, or more sturdy formed Mayer rods.\u003c\/p\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Large Coating Area Available\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Precision_alignment.svg?v=1697630031\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eStandardized Bar Coating\u003cbr\u003efor Repeatable Thicknesses\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eAutomated system for constistent\u003cbr\u003eand reliable coatings every time\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Full set of Mayer bars\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon-large-coating-area.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eUniform Coatings on\u003cbr\u003ea Range of Substrates\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eUp to 225 mm coating widths across\u003cbr\u003ea 290 mm travel distance\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Set up your bar coater quickly\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Quick_release_or_Speed.svg?v=1697701268\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eEfficient Setup with\u003cbr\u003eQuick Lock Design\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eEasy stage and drip tray cleaning between different coatings\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Mayer bar coater\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/All_Icons_Multiple-size.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eRange of Wire-Wound\u003cbr\u003eor Formed Mayer Bars\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eTo quickly experiment with\u003cbr\u003ethicknesses from 6 to 200 µm\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cvideo class=\"widescreen\" controls=\"controls\" controlslist=\"nodownload\" crossorigin=\"\" height=\"636.234\" poster=\"https:\/\/cdn.ossila.com\/videos\/automatic-film-applicator-software.jpg\" preload=\"none\" title=\"Automatic Film Applicator Software\" width=\"848.328\"\u003e\n\u003csource src=\"https:\/\/cdn.ossila.com\/videos\/automatic-film-applicator-software.mp4\" type=\"video\/mp4\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"Automatic Film Applicator Software\",\n\"description\": \"Automatic Film Applicator Software\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/automatic-film-applicator-software.jpg\",\n\"uploadDate\": \"2025-12-15\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/automatic-film-applicator-software.mp4\",\n\"duration\": \"PT1M03S\"\n}\n\u003c\/script\u003e\u003c\/p\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003ch3 id=\"bar-coater-thickess\"\u003eBar Coater Thickness\u003c\/h3\u003e\n\u003chr\u003e\n\u003cp\u003eBar coater systems use Mayer bar coaters (metal bars with wire-wrapped around them, or bars formed into this shape) to coat a liquid across a large area. The spacing gaps created by the wire determine the wet film thickness. Both types of bar achieve highly reproducible films, but formed rods are less prone to damage and contamination with an easily controlled packing density of the grooves.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"Mayer bar coater diagram: relationship between wire diameter and wet film thickness\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/bar-coating-wire-diameter-film-thickness.svg?v=1721731444\" width=\"848\"\u003e\n\u003cfigcaption\u003eBar coater thickness\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe relationship between wire diameter and wet film coating thickness is approximately linear. For example, a Mayer bar using a wire with 0.06 mm diameter will produce a wet film thickness of 6 µm, a 0.47 mm bar will produce a 50 µm wet film, up to the 200 µm bar which has a diameter of 1.86 mm. Slight variations in this linear relationship could be due to interactions between the wire bar and coating solution, or the coating solution viscosity\/concentration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"specification\"\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3 id=\"specification\"\u003eAutomatic Film Applicator\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Stage Travel Length\u003c\/th\u003e\n\u003ctd\u003e290 mm (A4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMinimum Stage Speed\u003c\/th\u003e\n\u003ctd\u003e0.05 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Stage Speed\u003c\/th\u003e\n\u003ctd\u003e250 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eStage Speed Increments\u003c\/th\u003e\n\u003ctd\u003e0.01 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVacuum Stage\u003c\/th\u003e\n\u003ctd\u003eAnodized aluminum stage, 0.8 mm vacuum holes, square grid arrangement (7.75 mm spacing), 6 mm push-fit connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass Stage\u003c\/th\u003e\n\u003ctd\u003e8 mm toughened glass, printed grid pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Coating Width\u003c\/th\u003e\n\u003ctd\u003e225 mm (accommodates Mayer bars with a 255 mm coating width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMinimum Mayer Bar Length\u003c\/th\u003e\n\u003ctd\u003e220 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eDC 24 V, 2 A, via 100 – 240 V 50\/60 Hz power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDimensions (D x W x H)\u003c\/th\u003e\n\u003ctd\u003e360 mm x 280 mm x 190 mm (14.2\" x 11\" x 7.5\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e6.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg alt=\"Ossila Bar Coating Kit Wireframe\" height=\"438.75\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automated-thin-film-applicator-wire-frame.svg?v=1734600279\" width=\"636\"\u003e\u003c\/figure\u003e\n\u003ch3 id=\"specification\"\u003eMayer Rods\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCoating Width\u003c\/th\u003e\n\u003ctd\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eRod Material\u003c\/th\u003e\n\u003ctd\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eEnd Machining\u003c\/th\u003e\n\u003ctd\u003eM4 tapped\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eTotal Width\u003c\/th\u003e\n\u003ctd\u003e240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWire-Wound Rod Diameter\u003c\/th\u003e\n\u003ctd\u003e9.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFormed Rod Diameter\u003c\/th\u003e\n\u003ctd\u003e8.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoating Thicknesses in Set (µm)\u003c\/th\u003e\n\u003ctd\u003e6, 8, 10, 12, 15, 20, 25, 30, 40, 50, 60, 80, 100, 120, 150, 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"process\"\u003eBar Coating Process\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eBar coating is a relatively simple technique, allowing users to create uniform large-area thin films. The process can be optimized through variation of the following parameters:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBar height and pressure\u003c\/li\u003e\n\u003cli\u003eBar speed\u003c\/li\u003e\n\u003cli\u003eSolution concentration\u003c\/li\u003e\n\u003cli\u003eSolution viscosity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing an automated bar coating machine can help improve process consistency and reliability by keeping bar pressure and speed consistent. Some other tips for optimizing your bar coating process include:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eEnsure your substrate and bar coater are clean before coating. Any dirt or debris can cause defects that can run through the entire film.\u003c\/li\u003e\n\u003cli\u003eMake sure your substrate is held firmly in place during coating. Vacuum stages can be useful for this application as they will hold flexible substrates still, flat and level.\u003c\/li\u003e\n\u003cli\u003eUse a spirit level to make sure your bar coater machine is level in all directions. This can help maintain unform coating along the desired coating width.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 id=\"features\"\u003eStandardize Your Bar Coating\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Full sets of mayer rods\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/All_Icons_Multiple-size.svg\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\" style=\"padding-top: 10px;\"\u003eWide Range of Optimization Options\u003c\/p\u003e\n\u003cp\u003eA set of 16 Mayer rods, either wire-wound or formed, give you complete flexibility to explore coating thicknesses from 6 µm to 200 µm. The bar coater achieves smooth, reliable movement across a range of programmable speeds for coating a wide range of solution viscosities without forming defects.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Large bar coating area\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon-large-coating-area.svg?v=1731401281\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\" style=\"padding-top: 10px;\"\u003eVersatile Coating Area\u003c\/p\u003e\n\u003cp\u003eCoat large-area samples, including sheet samples up to A4 size, with this complete bar coating system. With a programmable travel range up to 290 mm, you can also switch out your Mayer bars to vary your coating width because the system accommodates bar widths from 220 mm to 255 mm. And the automated system is also compatible with other coating accessories like blade coaters, Sheen applicators, or Bird applicators.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Vacuum compatible\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Processing_icons_Stainless_steel_tray.svg?v=1718708006\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\" style=\"padding-top: 10px;\"\u003eIdeal for Flexible Substrates\u003c\/p\u003e\n\u003cp\u003eIf you are coating flexible substrates, choose our vacuum model paired with the Ossila Vaccum Pump. With a maximum vacuum of 330 mbar and a 7 L\/min maximum flow rate, it is perfect for securing flexible or foil substrates. Keeping your flexible substrate still and level is essential to producing uniform, defect-free coatings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eBar Coater Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cvideo alt=\"Bar Coating\" autoplay=\"autoplay\" class=\"widescreen\" height=\"477.17\" loop=\"loop\" muted=\"muted\" src=\"https:\/\/cdn.ossila.com\/videos\/automatic-film-applicator-coating-loop.mp4\" title=\"Automatic Film Applicator Coating\" type=\"video\/mp4\" width=\"848.33\"\u003e\u003c\/video\u003e\u003c\/p\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator.jpg?v=1735648770\" title=\"Automatic film applicator system\"\u003e \u003cimg alt=\"Automatic film applicator system\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator.jpg?v=1735648770\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-coater-bar-coating.jpg?v=1735648770\" title=\"Bar coating set up\"\u003e \u003cimg alt=\"Bar coating set up\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-coater-bar-coating.jpg?v=1735648770\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-applicator-mayer-rod-printing.jpg?v=1748614890\" title=\"Bar Coater Mayer rod close up\"\u003e \u003cimg alt=\"Bar Coating Mayer rod close up\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-applicator-mayer-rod-printing.jpg?v=1748614890\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator-software.jpg?v=1735648772\" title=\"Automatic Film Applicator software\"\u003e \u003cimg alt=\"Automatic Film Applicator software\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator-software.jpg?v=1735648772\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/mayer-rod-cct-06-close-up.jpg\" title=\"Mayer rod 06 close up\"\u003e \u003cimg alt=\"Mayer rod 06 close up\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/mayer-rod-cct-06-close-up.jpg?width=420\u0026amp;height=280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/mayer-rod-cct-80-close-up.jpg\" title=\"Mayer rod 80 close up\"\u003e \u003cimg alt=\"Mayer rod 80 close up\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/mayer-rod-cct-80-close-up.jpg?width=420\u0026amp;height=280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/mayer-rod-cct-200-close-up.jpg\" title=\"Mayer rod 200 close up\"\u003e \u003cimg alt=\"Mayer rod 200 close up\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/mayer-rod-cct-200-close-up.jpg?width=420\u0026amp;height=280\" width=\"420\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca class=\"carousel-left-control\" role=\"button\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-left\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious \u003c\/span\u003e\u003c\/a\u003e \u003ca class=\"carousel-right-control\" role=\"button\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-right\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext \u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"included\"\u003eIn the Box\u003c\/h2\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eOssila Automatic Film Applicator\u003c\/li\u003e\n\u003cli\u003eMayer rod set (wire-wound or formed)\u003c\/li\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"accessories\"\u003eBar Coater Accessories\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e[[collection handle=\"equipment-accessories\" tags=\"Bar Coater\"]]\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/optimizing-bar-coating-process\"\u003e \u003cimg src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/mayer-rod-printing-opacity.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\" loading=\"lazy\" alt=\"How to Optimize Your Mayer Bar Coating Process\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.ossila.com\/pages\/optimizing-bar-coating-process\"\u003eHow to Optimize Your Mayer Bar Coating Process\u003c\/a\u003e\n\u003cp\u003eTThere are plenty of ways that you can optimize your bar coating process. Some of the main ways include changing Mayer rod and changing solution concentration and viscoscity.\u003c\/p\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/optimizing-bar-coating-process\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Wire-wound \/ Vacuum Bed \/ Type B (US)","offer_id":50424447762648,"sku":"L2009B1-W0-US","price":3500.0,"currency_code":"GBP","in_stock":true},{"title":"Wire-wound \/ Vacuum Bed \/ Type F (EU)","offer_id":50424447795416,"sku":"L2009B1-W0-EU","price":3500.0,"currency_code":"GBP","in_stock":true},{"title":"Wire-wound \/ Vacuum Bed \/ Type G (UK)","offer_id":50424447828184,"sku":"L2009B1-W0-UK","price":3500.0,"currency_code":"GBP","in_stock":true},{"title":"Wire-wound \/ Vacuum Bed \/ Type I (AU)","offer_id":50424447860952,"sku":"L2009B1-W0-AU","price":3500.0,"currency_code":"GBP","in_stock":true},{"title":"Wire-wound \/ Vacuum Bed \/ Type D\/H\/K\/L\/M\/N","offer_id":50424447893720,"sku":"L2009B1-W0","price":3500.0,"currency_code":"GBP","in_stock":false},{"title":"Wire-wound \/ Vacuum Bed + Vacuum Pump \/ Type B (US)","offer_id":51151953625304,"sku":"L2009C1-W0-US","price":3900.0,"currency_code":"GBP","in_stock":true},{"title":"Wire-wound \/ Vacuum Bed + Vacuum Pump \/ Type F (EU)","offer_id":51151969485016,"sku":"L2009C1-W0-EU","price":3900.0,"currency_code":"GBP","in_stock":true},{"title":"Wire-wound \/ Vacuum Bed + Vacuum Pump \/ Type G (UK)","offer_id":51151976988888,"sku":"L2009C1-W0-UK","price":3900.0,"currency_code":"GBP","in_stock":true},{"title":"Wire-wound \/ Vacuum Bed + Vacuum Pump \/ Type I (AU)","offer_id":51151981936856,"sku":"L2009C1-W0-AU","price":3900.0,"currency_code":"GBP","in_stock":true},{"title":"Wire-wound \/ Vacuum Bed + Vacuum Pump \/ Type D\/H\/K\/L\/M\/N","offer_id":51151982821592,"sku":"L2009C1-W0","price":3900.0,"currency_code":"GBP","in_stock":false},{"title":"Wire-wound \/ Glass \/ Type B (US)","offer_id":50125891666136,"sku":"L2009A1-W0-US","price":2750.0,"currency_code":"GBP","in_stock":true},{"title":"Wire-wound \/ Glass \/ Type F (EU)","offer_id":50125891698904,"sku":"L2009A1-W0-EU","price":2750.0,"currency_code":"GBP","in_stock":true},{"title":"Wire-wound \/ Glass \/ Type G (UK)","offer_id":50125891731672,"sku":"L2009A1-W0-UK","price":2750.0,"currency_code":"GBP","in_stock":true},{"title":"Wire-wound \/ Glass \/ Type I (AU)","offer_id":50125891764440,"sku":"L2009A1-W0-AU","price":2750.0,"currency_code":"GBP","in_stock":true},{"title":"Wire-wound \/ Glass \/ Type D\/H\/K\/L\/M\/N","offer_id":50125891797208,"sku":"L2009A1-W0","price":2750.0,"currency_code":"GBP","in_stock":false},{"title":"Formed \/ Vacuum Bed \/ Type B (US)","offer_id":50424447926488,"sku":"L2009B1-F0-US","price":3600.0,"currency_code":"GBP","in_stock":true},{"title":"Formed \/ Vacuum Bed \/ Type F (EU)","offer_id":50424447959256,"sku":"L2009B1-F0-EU","price":3600.0,"currency_code":"GBP","in_stock":true},{"title":"Formed \/ Vacuum Bed \/ Type G (UK)","offer_id":50424447992024,"sku":"L2009B1-F0-UK","price":3600.0,"currency_code":"GBP","in_stock":true},{"title":"Formed \/ Vacuum Bed \/ Type I (AU)","offer_id":50424448024792,"sku":"L2009B1-F0-AU","price":3600.0,"currency_code":"GBP","in_stock":true},{"title":"Formed \/ Vacuum Bed \/ Type D\/H\/K\/L\/M\/N","offer_id":50424448057560,"sku":"L2009B1-F0","price":3600.0,"currency_code":"GBP","in_stock":false},{"title":"Formed \/ Vacuum Bed + Vacuum Pump \/ Type B (US)","offer_id":51151984099544,"sku":"L2009C1-F0-US","price":4000.0,"currency_code":"GBP","in_stock":true},{"title":"Formed \/ Vacuum Bed + Vacuum Pump \/ Type F (EU)","offer_id":51151984361688,"sku":"L2009C1-F0-EU","price":4000.0,"currency_code":"GBP","in_stock":true},{"title":"Formed \/ Vacuum Bed + Vacuum Pump \/ Type G (UK)","offer_id":51151984394456,"sku":"L2009C1-F0-UK","price":4000.0,"currency_code":"GBP","in_stock":true},{"title":"Formed \/ Vacuum Bed + Vacuum Pump \/ Type I (AU)","offer_id":51151985311960,"sku":"L2009C1-F0-AU","price":4000.0,"currency_code":"GBP","in_stock":true},{"title":"Formed \/ Vacuum Bed + Vacuum Pump \/ Type D\/H\/K\/L\/M\/N","offer_id":51151985508568,"sku":"L2009C1-F0","price":4000.0,"currency_code":"GBP","in_stock":false},{"title":"Formed \/ Glass \/ Type B (US)","offer_id":50125894746328,"sku":"L2009A1-F0-US","price":2850.0,"currency_code":"GBP","in_stock":true},{"title":"Formed \/ Glass \/ Type F (EU)","offer_id":50125894779096,"sku":"L2009A1-F0-EU","price":2850.0,"currency_code":"GBP","in_stock":true},{"title":"Formed \/ Glass \/ Type G (UK)","offer_id":50125894811864,"sku":"L2009A1-F0-UK","price":2850.0,"currency_code":"GBP","in_stock":true},{"title":"Formed \/ Glass \/ Type I (AU)","offer_id":50125894844632,"sku":"L2009A1-F0-AU","price":2850.0,"currency_code":"GBP","in_stock":true},{"title":"Formed \/ Glass \/ Type D\/H\/K\/L\/M\/N","offer_id":50125894877400,"sku":"L2009A1-F0","price":2850.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/bar-coating-bundle-vacuum-bed.jpg?v=1751553538"},{"product_id":"doctor-blade-coater","title":"Doctor Blade Coater","description":"\u003ch2 id=\"product-oneliner\"\u003eHigh Quality Coatings with an Automatic, Adjustable System\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003ePrecise, simple, and efficient optimization in your research\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#included\"\u003eIn the Box\u003c\/a\u003e | \u003ca href=\"#resources\"\u003e Resources \u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eTake control of essential coating parameters with our automatic doctor blade coater. The included applicator is made from stainless steel with digital micrometer gauges. Make micron-level adjustments to the gap height (up to 10 mm) with ultimate accuracy for a range of film thicknesses as you optimize your coatings.\u003c\/p\u003e\n\u003cp\u003eThe integrated software makes it easy to adjust and set the coating speed, from 0.05 mm.s\u003csup\u003e-1\u003c\/sup\u003e to 250 mm.s\u003csup\u003e-1\u003c\/sup\u003e. Beyond blade coating, you can also use Mayer rods, which can be purchased separately, for further flexibility as you experiment with and optimize your coatings. The doctor blade coater can either come with a simple glass stage or a vacuum stage for uniform holding across the whole substrate.\u003c\/p\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Precision_alignment.svg?v=1697630031\" loading=\"lazy\" height=\"50\" alt=\"Repeatable and customizable coatings\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eDigital Micrometer for\u003cbr\u003ePrecise Blade Positioning\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eControl the gap height for tight control\u003cbr\u003eof coating thicknesses\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Wide_Working_Space.svg?v=1697622912\" loading=\"lazy\" height=\"50\" alt=\"Large area films\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eUniform Coatings on\u003cbr\u003ea Range of Substrates\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eUp to 200 mm coating widths across\u003cbr\u003ea 290 mm travel distance\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Quick_release_or_Speed.svg?v=1697701268\" loading=\"lazy\" height=\"50\" alt=\"Set up your doctor blade coater quickly\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eEfficient Setup with\u003cbr\u003eQuick Lock Design\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eEasy stage and drip tray cleaning between different coatings\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Lab_Proof.svg\" loading=\"lazy\" height=\"50\" alt=\"Use with a wide range of materials\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eCustomizable Stainless\u003cbr\u003eSteel Applicator\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eCoat with materials that require\u003cbr\u003ehigher chemical resistance\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure\u003e\u003cvideo width=\"848.328\" title=\"Doctor Blade Coater Product Overview\" preload=\"none\" poster=\"https:\/\/cdn.ossila.com\/videos\/doctor-blade-coating-bundle-product-overview.jpg\" height=\"477.172\" crossorigin=\"\" controlslist=\"nodownload\" controls=\"controls\" class=\"widescreen\"\u003e\n\u003csource type=\"video\/mp4\" src=\"https:\/\/cdn.ossila.com\/videos\/doctor-blade-coating-bundle-product-overview.mp4\"\u003e\n\u003ctrack srclang=\"en\" src=\"https:\/\/cdn.ossila.com\/videos\/doctor-blade-coating-bundle-product-overview.vtt\" label=\"English\" kind=\"subtitles\" default=\"\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"Ossila Doctor Blade Coater Overview\",\n\"description\": \"Ossila Doctor Blade Coater Product Overview\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/doctor-blade-coating-bundle-product-overview.jpg\",\n\"uploadDate\": \"2025-03-04\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/doctor-blade-coating-bundle-product-overview.mp4\",\n\"duration\": \"PT0M29S\"\n}\n\u003c\/script\u003e\u003c\/figure\u003e\n\u003ch2 id=\"specification\"\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eAutomatic Film Applicator\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Stage Travel Length\u003c\/th\u003e\n\u003ctd\u003e290 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMinimum Stage Speed\u003c\/th\u003e\n\u003ctd\u003e0.05 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Stage Speed\u003c\/th\u003e\n\u003ctd\u003e250 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eStage Speed Increments\u003c\/th\u003e\n\u003ctd\u003e0.01 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVacuum Stage\u003c\/th\u003e\n\u003ctd\u003eAnodized aluminum stage, 0.8 mm vacuum holes, square grid arrangement (7.75 mm spacing), 6 mm push-fit connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGlass Stage\u003c\/th\u003e\n\u003ctd\u003e8 mm toughened glass, printed grid pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eDC 24 V, 2 A, via 100 – 240 V 50\/60 Hz power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDimensions (D x W x H)\u003c\/th\u003e\n\u003ctd\u003e360 mm x 280 mm x 190 mm (14.2\" x 11\" x 7.5\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e6.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg width=\"598\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/product-wireframes-doctor-blade-coater.svg\" loading=\"lazy\" height=\"452\" alt=\"Doctor Blade Coater wireframe\"\u003e\u003c\/figure\u003e\n\u003ch3 id=\"specification\"\u003eAdjustable Film Applicator\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCoating Widths\u003c\/th\u003e\n\u003ctd\u003e100 mm, 200 mm, and custom (50 mm – 200 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003e304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eGap Height\u003c\/th\u003e\n\u003ctd\u003e0 – 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGauge Type\u003c\/th\u003e\n\u003ctd\u003eDigital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eGauge Resolution\u003c\/th\u003e\n\u003ctd\u003e1 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eGauge Accuracy\u003c\/th\u003e\n\u003ctd\u003e3 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"features\"\u003ePrecise Coating Control\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Precision_alignment.svg\" loading=\"lazy\" height=\"112\" alt=\"Micrometer heads offer precision in coating\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\" style=\"padding-top: 10px;\"\u003eEasy and Precise Optimization\u003c\/p\u003e\n\u003cp\u003eThe digital micrometer head provides high accuracy blade positioning. For improved reproducibility and efficiency, the blade is calibrated to the zero position of the micrometer gauge. Then, optimize your coatings with smooth, reliable movement at speeds as low as 0.05 mm.s-1 and as high as 250 mm.s-1. Choose the right speed for a wide range of solution viscosities and consistently produce coatings without defects.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon-large-coating-area.svg?v=1731401281\" loading=\"lazy\" height=\"112\" alt=\"Large coatings for scaling optimization\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\" style=\"padding-top: 10px;\"\u003eVersatile Coating Area\u003c\/p\u003e\n\u003cp\u003eWith a maximum travel distance of 290 mm, scaling up your doctor blade coating processes has never been easier. You can customize the width of your film applicator to match your research needs, with coating widths as low as 50 mm up to 200 mm. And the automated system is also compatible with other coating accessories like Mayer bars, Sheen applicators, or Bird applicators.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Processing_icons_Stainless_steel_tray.svg\" loading=\"lazy\" height=\"112\" alt=\"Vacuum compatible\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\" style=\"padding-top: 10px;\"\u003eIdeal for Flexible Substrates\u003c\/p\u003e\n\u003cp\u003eIf you are coating flexible substrates, choose our vacuum model paired with the Ossila Vaccum Pump. With a maximum vacuum of 330 mbar and a 7 L\/min maximum flow rate, it is perfect for securing flexible or foil substrates. Keeping your flexible substrate still and level is essential to producing uniform, defect-free coatings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eDoctor Blade Coater Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track\"\u003e\n\u003ca title=\"Accurate digital micrometer readout\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/thin-film-applicator-plus-in-use.jpg?\u0026amp;width=1620\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/thin-film-applicator-plus-in-use.jpg?width=420\u0026amp;height=280\" loading=\"lazy\" height=\"280\" alt=\"Accurate digital micrometer readout\"\u003e \u003c\/a\u003e \u003ca title=\"The Ossila Doctor Blade Coater\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/thin-film-applicator-plus-bundle.jpg?\u0026amp;width=1620\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/thin-film-applicator-plus-bundle.jpg?width=420\u0026amp;height=280\" loading=\"lazy\" height=\"280\" alt=\"The Ossila Doctor Blade Coater\"\u003e \u003c\/a\u003e \u003ca title=\"Automatic system for a range of speeds\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator.jpg?\u0026amp;width=1620\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/automatic-film-applicator.jpg?width=420\u0026amp;height=280\" loading=\"lazy\" height=\"280\" alt=\"Automatic system for a range of speeds\"\u003e \u003c\/a\u003e \u003ca title=\"Digital adjustable film applicator\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/guage-thin-film-applicator-plus.jpg?amp;width=1620\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/guage-thin-film-applicator-plus.jpg?width=420\u0026amp;height=280\" loading=\"lazy\" height=\"280\" alt=\"Digital adjustable film applicator\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca role=\"button\" class=\"carousel-left-control\"\u003e \u003csvg class=\"icon icon-chevron-left\" aria-hidden=\"true\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious \u003c\/span\u003e\u003c\/a\u003e \u003ca role=\"button\" class=\"carousel-right-control\"\u003e \u003csvg class=\"icon icon-chevron-right\" aria-hidden=\"true\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext \u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"included\"\u003eIn the Box\u003c\/h2\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eOssila Automatic Film Applicator\u003c\/li\u003e\n\u003cli\u003eStainless steel adjustable film applicator\u003c\/li\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"accessories\"\u003eDoctor Blade Coater Accessories\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e[[collection handle=\"equipment-accessories\" tags=\"Doctor Blade Coater\"]]\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/doctor-blade-coater-set-up-use-maintenance\"\u003e \u003cimg alt=\"How to Optimize Your Mayer Bar Coating Process\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/guage-thin-film-applicator-plus.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.ossila.com\/pages\/doctor-blade-coater-set-up-use-maintenance\"\u003eDoctor Blade Coater: Set Up, Use and Maintenance\u003c\/a\u003e\n\u003cp\u003eDoctor blade coating is an easy way of making uniform thin films over large areas. It is great for coating flexible substrates, foils and polymer films.\u003c\/p\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/doctor-blade-coater-set-up-use-maintenance\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"100 mm \/ Vacuum Bed \/ Type B (US)","offer_id":50424438751448,"sku":"L2009B1-E2-US","price":3400.0,"currency_code":"GBP","in_stock":true},{"title":"100 mm \/ Vacuum Bed \/ Type F (EU)","offer_id":50424438784216,"sku":"L2009B1-E2-EU","price":3400.0,"currency_code":"GBP","in_stock":true},{"title":"100 mm \/ Vacuum Bed \/ Type G (UK)","offer_id":50424438816984,"sku":"L2009B1-E2-UK","price":3400.0,"currency_code":"GBP","in_stock":true},{"title":"100 mm \/ Vacuum Bed \/ Type I (AU)","offer_id":50424438849752,"sku":"L2009B1-E2-AU","price":3400.0,"currency_code":"GBP","in_stock":true},{"title":"100 mm \/ Vacuum Bed \/ Type D\/H\/K\/L\/M\/N","offer_id":50424438882520,"sku":"L2009B1-E2","price":3400.0,"currency_code":"GBP","in_stock":false},{"title":"100 mm \/ Vacuum Bed + Vacuum Pump \/ Type B (US)","offer_id":51151912665304,"sku":"L2009C1-E2-US","price":3800.0,"currency_code":"GBP","in_stock":true},{"title":"100 mm \/ Vacuum Bed + Vacuum Pump \/ Type F (EU)","offer_id":51151912698072,"sku":"L2009C1-E2-EU","price":3800.0,"currency_code":"GBP","in_stock":true},{"title":"100 mm \/ Vacuum Bed + Vacuum Pump \/ Type G (UK)","offer_id":51151912730840,"sku":"L2009C1-E2-UK","price":3800.0,"currency_code":"GBP","in_stock":true},{"title":"100 mm \/ Vacuum Bed + Vacuum Pump \/ Type I (AU)","offer_id":51151912763608,"sku":"L2009C1-E2-AU","price":3800.0,"currency_code":"GBP","in_stock":true},{"title":"100 mm \/ Vacuum Bed + Vacuum Pump \/ Type D\/H\/K\/L\/M\/N","offer_id":51151912796376,"sku":"L2009C1-E2","price":3800.0,"currency_code":"GBP","in_stock":false},{"title":"100 mm \/ Glass \/ Type B (US)","offer_id":50126694678744,"sku":"L2009A1-E2-US","price":2650.0,"currency_code":"GBP","in_stock":true},{"title":"100 mm \/ Glass \/ Type F (EU)","offer_id":50126694711512,"sku":"L2009A1-E2-EU","price":2650.0,"currency_code":"GBP","in_stock":true},{"title":"100 mm \/ Glass \/ Type G (UK)","offer_id":50126694744280,"sku":"L2009A1-E2-UK","price":2650.0,"currency_code":"GBP","in_stock":true},{"title":"100 mm \/ Glass \/ Type I (AU)","offer_id":50126694777048,"sku":"L2009A1-E2-AU","price":2650.0,"currency_code":"GBP","in_stock":true},{"title":"100 mm \/ Glass \/ Type D\/H\/K\/L\/M\/N","offer_id":50126694809816,"sku":"L2009A1-E2","price":2650.0,"currency_code":"GBP","in_stock":false},{"title":"200 mm \/ Vacuum Bed \/ Type B (US)","offer_id":50424438915288,"sku":"L2009B1-E3-US","price":3450.0,"currency_code":"GBP","in_stock":true},{"title":"200 mm \/ Vacuum Bed \/ Type F (EU)","offer_id":50424438948056,"sku":"L2009B1-E3-EU","price":3450.0,"currency_code":"GBP","in_stock":true},{"title":"200 mm \/ Vacuum Bed \/ Type G (UK)","offer_id":50424438980824,"sku":"L2009B1-E3-UK","price":3450.0,"currency_code":"GBP","in_stock":true},{"title":"200 mm \/ Vacuum Bed \/ Type I (AU)","offer_id":50424439013592,"sku":"L2009B1-E3-AU","price":3450.0,"currency_code":"GBP","in_stock":true},{"title":"200 mm \/ Vacuum Bed \/ Type D\/H\/K\/L\/M\/N","offer_id":50424439046360,"sku":"L2009B1-E3","price":3450.0,"currency_code":"GBP","in_stock":false},{"title":"200 mm \/ Vacuum Bed + Vacuum Pump \/ Type B (US)","offer_id":51151912829144,"sku":"L2009C1-E3-US","price":3850.0,"currency_code":"GBP","in_stock":true},{"title":"200 mm \/ Vacuum Bed + Vacuum Pump \/ Type F (EU)","offer_id":51151912861912,"sku":"L2009C1-E3-EU","price":3850.0,"currency_code":"GBP","in_stock":true},{"title":"200 mm \/ Vacuum Bed + Vacuum Pump \/ Type G (UK)","offer_id":51151912894680,"sku":"L2009C1-E3-UK","price":3850.0,"currency_code":"GBP","in_stock":true},{"title":"200 mm \/ Vacuum Bed + Vacuum Pump \/ Type I (AU)","offer_id":51151912927448,"sku":"L2009C1-E3-AU","price":3850.0,"currency_code":"GBP","in_stock":true},{"title":"200 mm \/ Vacuum Bed + Vacuum Pump \/ Type D\/H\/K\/L\/M\/N","offer_id":51151912960216,"sku":"L2009C1-E3","price":3850.0,"currency_code":"GBP","in_stock":false},{"title":"200 mm \/ Glass \/ Type B (US)","offer_id":50126694842584,"sku":"L2009A1-E3-US","price":2700.0,"currency_code":"GBP","in_stock":true},{"title":"200 mm \/ Glass \/ Type F (EU)","offer_id":50126694875352,"sku":"L2009A1-E3-EU","price":2700.0,"currency_code":"GBP","in_stock":true},{"title":"200 mm \/ Glass \/ Type G (UK)","offer_id":50126694908120,"sku":"L2009A1-E3-UK","price":2700.0,"currency_code":"GBP","in_stock":true},{"title":"200 mm \/ Glass \/ Type I (AU)","offer_id":50126694940888,"sku":"L2009A1-E3-AU","price":2700.0,"currency_code":"GBP","in_stock":true},{"title":"200 mm \/ Glass \/ Type D\/H\/K\/L\/M\/N","offer_id":50126694973656,"sku":"L2009A1-E3","price":2700.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Vacuum Bed \/ Type B (US)","offer_id":50424439079128,"sku":"L2009B1-E0-US","price":3850.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Vacuum Bed \/ Type F (EU)","offer_id":50424439111896,"sku":"L2009B1-E0-EU","price":3850.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Vacuum Bed \/ Type G (UK)","offer_id":50424439144664,"sku":"L2009B1-E0-UK","price":3850.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Vacuum Bed \/ Type I (AU)","offer_id":50424439177432,"sku":"L2009B1-E0-AU","price":3850.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Vacuum Bed \/ Type D\/H\/K\/L\/M\/N","offer_id":50424439210200,"sku":"L2009B1-E0","price":3850.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Vacuum Bed + Vacuum Pump \/ Type B (US)","offer_id":51151912992984,"sku":"L2009C1-E0-US","price":4250.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Vacuum Bed + Vacuum Pump \/ Type F (EU)","offer_id":51151913025752,"sku":"L2009C1-E0-EU","price":4250.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Vacuum Bed + Vacuum Pump \/ Type G (UK)","offer_id":51151913058520,"sku":"L2009C1-E0-UK","price":4250.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Vacuum Bed + Vacuum Pump \/ Type I (AU)","offer_id":51151913091288,"sku":"L2009C1-E0-AU","price":4250.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Vacuum Bed + Vacuum Pump \/ Type D\/H\/K\/L\/M\/N","offer_id":51151913124056,"sku":"L2009C1-E0","price":4250.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Glass \/ Type B (US)","offer_id":50206260330712,"sku":"L2009A1-E0-US","price":3100.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Glass \/ Type F (EU)","offer_id":50206260363480,"sku":"L2009A1-E0-EU","price":3100.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Glass \/ Type G (UK)","offer_id":50206260396248,"sku":"L2009A1-E0-UK","price":3100.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Glass \/ Type I (AU)","offer_id":50206260429016,"sku":"L2009A1-E0-AU","price":3100.0,"currency_code":"GBP","in_stock":false},{"title":"Custom width \/ Glass \/ Type D\/H\/K\/L\/M\/N","offer_id":50206260461784,"sku":"L2009A1-E0","price":3100.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/digital-doctor-blade-bundle-vacuum-bed-product-photo.jpg?v=1768578551"},{"product_id":"spray-coater","title":"Spray Coater","description":"\u003ch2 id=\"product-oneliner\"\u003ePrepare to Scale Up with a Low Price Spray System\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eMatch your solution to the optimal spray method with interchangeable heads and nozzles\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#included\"\u003eIn the Box\u003c\/a\u003e | \u003ca href=\"#technical-support\"\u003eTechnical Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eOptimize your spray coating process with a benchtop system so you can ensure an efficient and reliable scale up. The interchangeable heads make this spray coater suitable for a range of different solutions, and you can achieve a wide range of spray patterns and droplet sizes by controlling the gas and fluid pressure.\u003c\/p\u003e\n\u003cp\u003eTo align with large-scale, automated setups, you can program your coating speed to a resolution of 0.1 mm.s\u003csup\u003e-1\u003c\/sup\u003e for reliable and repeatable coating movement. Test the best spray alignment for wide and uniform spray patterns by manually adjusting the head position and height or combining multiple spray heads on the gantry. Once your substrate is coated, take control of the drying process with the heated stage, which can reach 100 °C, to prevent defects from forming during the delicate curing window.\u003c\/p\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Full_Control.svg?v=1697630031\" loading=\"lazy\" height=\"50\" alt=\"Repeatable bar coating processes\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eEasy Control of Coating Parameters\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eAdjust pressure, height, speed, and temperature to achieve uniformity\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/2D-Materials-Icons_-Different_Forms.svg\" loading=\"lazy\" height=\"50\" alt=\"Full set of Mayer bars\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eUltrasonic \u0026amp; Atomizing Heads\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eFor a range of spray patterns and droplet sizes with different solution types\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"40\" style=\"margin-bottom: 10px;\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Wide_Working_Space.svg?v=1697622912\" loading=\"lazy\" height=\"40\" alt=\"Bar coating for uniform films\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eEfficient Lab-Scale Optimization\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eExperiment with multi-head coverage over 200 mm x 180 mm substrates\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg width=\"50\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila_Guarantee_Icons_Streamlined.svg?v=1697701268\" loading=\"lazy\" height=\"50\" alt=\"Set up your bar coating system quickly\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eWide Substrate Compatibility\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eCoat more complex large-area, flexible, and textured substrates with ease\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"specification\"\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Sample Size\u003c\/th\u003e\n\u003ctd\u003e200 mm x 180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMinimum Stage Speed\u003c\/th\u003e\n\u003ctd\u003e0.05 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Stage Speed\u003c\/th\u003e\n\u003ctd\u003e250 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eStage Speed Increments\u003c\/th\u003e\n\u003ctd\u003e0.01 mm.s\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eHeated Stage Max Temperature\u003c\/th\u003e\n\u003ctd\u003e100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eHeating Increments\u003c\/th\u003e\n\u003ctd\u003e1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAir Pressure\u003c\/th\u003e\n\u003ctd\u003e0.15 to 7.0 Bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFluid Pressure\u003c\/th\u003e\n\u003ctd\u003e0.1 to 3.5 Bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eUltrasonic Spray Head\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpray Pattern\u003c\/th\u003e\n\u003ctd\u003eCone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpray Angle\u003c\/th\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDroplet Size\u003c\/th\u003e\n\u003ctd\u003e18 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSolution Mixing\u003c\/th\u003e\n\u003ctd\u003eExternal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGas Atomizing Spray Head\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpray Pattern\u003c\/th\u003e\n\u003ctd\u003eCone or fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSpray Angle\u003c\/th\u003e\n\u003ctd\u003e15 to 90 (depending on air cap)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDroplet Size\u003c\/th\u003e\n\u003ctd\u003e30 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSolution Mixing\u003c\/th\u003e\n\u003ctd\u003eInternal or external (depending on air cap)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003ca href=\"#specifications-cont\"\u003eView more specifications\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eLab-Scale Spray Coating Machine\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Easier_Ink_Optimisation.svg\" loading=\"lazy\" height=\"112\" class=\"img-round\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eExperiment with Spray Heads\u003c\/p\u003e\n\u003cp\u003eFind the best setup for your coating requirements by experimenting with the two included spray heads. When using the air atomizing head, choose the best spray pattern using different nozzles. The air and liquid pressure regulators and inlet adapters allow full control as you pressure drive fluids, or simply operate the spray heads in syphon mode.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Processing_icons_Stainless_steel_tray.svg\" loading=\"lazy\" height=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eFully Optimize Different Coatings\u003c\/p\u003e\n\u003cp\u003eCustomize your spray coating process with an automated system. Make small and measured adjustments to your coating speed across a wide range, then use the heated stage to improve the drying process and take greater control over film uniformity. Plus, there is simple spray head positioning along the vertical and horizontal axis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg width=\"112\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/All_Icons_Multiple-size.svg\" loading=\"lazy\" height=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eSimplify Your Scale Up Process\u003c\/p\u003e\n\u003cp\u003eTransition from small-scale coating techniques, like spin coating, with this easy-to-use system. The spray coater stage is designed to accommodate larger area samples. With space to mount multiple heads side by side, you can optimize your spray overlap patterns and produce larger highly uniform thin films.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eSpray Coater Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca title=\"Laboratory Spray Coating System\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spray-coater-coating-heights.jpg?width=1024\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spray-coater-coating-heights.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"Laboratory Spray Coating System\"\u003e \u003c\/a\u003e \u003ca title=\"Ultrasonic Spray Head\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ultrasonic-spray-head-spray-coater.jpg?width=1024\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ultrasonic-spray-head-spray-coater.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"Ultrasonic Spray Head\"\u003e \u003c\/a\u003e \u003ca title=\"Automatic stage controls\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spray-coater-view.jpg?width=1024\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spray-coater-view.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"Automatic stage controls\"\u003e \u003c\/a\u003e \u003ca title=\"Gas Atomizing Spray Head\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spray-coater-gas-atomizing-spray-head.jpg?width=1024\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spray-coater-gas-atomizing-spray-head.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"Gas Atomizing Spray Head\"\u003e \u003c\/a\u003e \u003ca title=\"Adjustable spray head gantry\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/using-the-ossila-spray-coater.jpg?width=1024\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/using-the-ossila-spray-coater.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"Adjustable spray head gantry\"\u003e \u003c\/a\u003e \u003ca title=\"Optimize your spray coater setup\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-spray-coater-measurement.jpg?width=1024\" class=\"carousel-item\"\u003e \u003cimg width=\"420\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-spray-coater-measurement.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" alt=\"Optimize your spray coater setup\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca role=\"button\" class=\"carousel-left-control\"\u003e \u003csvg class=\"icon icon-chevron-left\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious \u003c\/span\u003e\u003c\/a\u003e \u003ca role=\"button\" class=\"carousel-right-control\"\u003e \u003csvg class=\"icon icon-chevron-right\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext \u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cfigure class=\"margin-top\"\u003e\u003cvideo width=\"848.33\" type=\"video\/mp4\" title=\"Stage travel of the Ossila Spray Coater\" src=\"https:\/\/cdn.ossila.com\/videos\/spray-coater-stage-travel-loop.mp4\" muted=\"muted\" loop=\"loop\" height=\"477.17\" class=\"widescreen\" autoplay=\"autoplay\" alt=\"Spray Coater stage travel demonstration\"\u003e\u003c\/video\u003e\u003c\/figure\u003e\n\u003ch2 id=\"specifications-cont\"\u003eAdditional Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure class=\"padding-bottom\"\u003e\u003cimg width=\"430\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spray-coater-wireframe.svg?v=1756376784\" loading=\"lazy\" height=\"494\" alt=\"Spray Coater Diagram\"\u003e\u003c\/figure\u003e\n\u003ch3\u003eSpray Coater\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Stage Travel Length\u003c\/th\u003e\n\u003ctd\u003e280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eHeated Stage Material\u003c\/th\u003e\n\u003ctd\u003eHard anodized aluminum stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eDC 24 V, 5 A, via 100 – 240 V 50\/60 Hz power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDimensions (D x W x H)\u003c\/th\u003e\n\u003ctd\u003e350 mm x 280 mm x 550 mm (14\" x 11\" x 22\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e6.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eUltrasonic Spray Head\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSolution Delivery\u003c\/th\u003e\n\u003ctd\u003eSyphon or pressure driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eInlets\u003c\/th\u003e\n\u003ctd\u003eG1\/8 liquid, G1\/4 gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eStainless steel 316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGas Atomizing Spray Head\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSolution Delivery\u003c\/th\u003e\n\u003ctd\u003eSyphon or pressure driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eInlets\u003c\/th\u003e\n\u003ctd\u003eG1\/4 liquid, G1\/4 gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eStainless steel 316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"included\"\u003eIn the Box\u003c\/h2\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eSpray coater\u003c\/li\u003e\n\u003cli\u003eUltrasonic spray head\u003c\/li\u003e\n\u003cli\u003eAir atomizing spray head and air caps\u003c\/li\u003e\n\u003cli\u003ePneumatic regulators and connectors\u003c\/li\u003e\n\u003cli\u003ePower supply (24V 5A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAir Atomizing Spray Head Nozzles\u003c\/h3\u003e\n\u003cp\u003eThese interchangeable nozzles come with the spray coater and can be used with the atomizing spray head.\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/internal-spray-coater-interchangeable-nozzle.jpg?v=\"\u003e\n\u003cfigure\u003e\u003cimg alt=\"Spray Coater Internal nozzle types\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/internal-spray-coater-interchangeable-nozzle.jpg?v=\" width=\"500\"\u003e\n\u003cfigcaption\u003eInternal Spray Head Nozzle Types\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/external-spray-coater-interchangeable-nozzle.jpg?v=\"\u003e\n\u003cfigure\u003e\u003cimg alt=\"Spray Coater nozzle shapes\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/external-spray-coater-interchangeable-nozzle.jpg?v=\" width=\"500\"\u003e\n\u003cfigcaption\u003eExternal Spray Head Nozzle Types\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Type B (US)","offer_id":50777352175832,"sku":"L2011A1-US","price":3200.0,"currency_code":"GBP","in_stock":true},{"title":"Type F (EU)","offer_id":50777352208600,"sku":"L2011A1-EU","price":3200.0,"currency_code":"GBP","in_stock":true},{"title":"Type G (UK)","offer_id":50777352241368,"sku":"L2011A1-UK","price":3200.0,"currency_code":"GBP","in_stock":true},{"title":"Type I (AU)","offer_id":50777352274136,"sku":"L2011A1-AU","price":3200.0,"currency_code":"GBP","in_stock":true},{"title":"Type D\/H\/K\/L\/M\/N","offer_id":50777352306904,"sku":"L2011A1","price":3200.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/spray-coater-product-photo.jpg?v=1768824412"}],"url":"https:\/\/www.ossila.com\/collections\/popular-products.oembed","provider":"Ossila","version":"1.0","type":"link"}