{"title":"Cleanroom Equipment","description":"\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#buy-glovebox\"\u003eGlove box \u0026amp; accessories\u003c\/a\u003e | \u003ca href=\"#buy-lfh\"\u003eLaminar flow hood \u0026amp; accessories\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources\u003c\/a\u003e | \u003ca href=\"#technical-support\"\u003eTechnical Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eImplement controlled workspace conditions with affordable systems that fit neatly onto your workbench, even in smaller labs. Ossila cleanroom equipment is designed as an affordable and high performance solution for labs that have no access to, or simply cannot afford, built-in cleanroom systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Ossila Glove Box achieves an inert atmosphere with very low oxygen and moisture levels and maintains your required conditions with a low leak rate and automated purge cycles. Built with the materials of larger, more expensive systems at the price point and size of benchtop acrylic alternatives.\u003c\/li\u003e\n\u003cli\u003eThe Ossila Laminar Flow Hood is a fully equipped system that includes everything you need to create a clean air workspace on your bench. Unlike comparable systems, the price advertised covers all the essential components for a feature-rich hood, so there are no unexpected add-ons that push the final cost up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"buy-glovebox\"\u003eBuy a Glove Box System\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e[[collection handle=\"cleanroom-equipment\" tags=\"glove box\"]]\u003c\/p\u003e\n\u003cdiv class=\"featured-product align-right light-green-background round-bottom\"\u003e\n\u003cdiv class=\"fade-section\"\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/products\/glove-box\"\u003e\n\u003cimg width=\"360\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glove-box-arms.jpg?width=360\u0026amp;height=400\u0026amp;crop=center\" loading=\"lazy\" height=\"400\" class=\"fade-element round-corners gradual-transition full-opacity\" alt=\"Ossila Glove Box\"\u003e \u003cimg width=\"360\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-glove-box.png?width=360\u0026amp;height=400\u0026amp;crop=right\" loading=\"lazy\" height=\"400\" class=\"fade-element round-corners gradual-transition\" alt=\"Glove box antechamber\"\u003e \u003cimg width=\"360\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-glove-box-software.jpg?width=360\u0026amp;height=400\u0026amp;crop=center\" loading=\"lazy\" height=\"400\" class=\"fade-element round-corners gradual-transition\" alt=\"Control interface\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"featured-product-info\"\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/products\/glove-box\" class=\"h1\"\u003eOssila Glove Box\u003c\/a\u003e\n\u003cp\u003eCreate a stable and sealed environment with the Ossila Glove Box, a complete benchtop system designed with affordability and simplicity in mind. Ideal for many inert atmosphere applications, from air sensitive experiments to handling hazardous materials and chemicals.\u003c\/p\u003e\n\u003cp\u003eMore affordable than large, standalone systems and significantly better performance than acrylic systems. Made with grade 304 stainless steel, 6 mm hardened glass, and butyl rubber gloves, ensure ultra-low moisture and oxygen ingress rates without the high price tag.\u003c\/p\u003e\n\u003cp\u003eWith a comprehensive and versatile suite of integrated features, our glove box is built for every laboratory, including yours.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ossila.com\/products\/glove-box\" class=\"featured-product-button\"\u003eOrder now\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"buy-lfh\"\u003eBuy a Laminar Flow System\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e[[collection handle=\"cleanroom-equipment\" tags=\"laminar flow hood\"]]\u003c\/p\u003e\n\u003cdiv class=\"featured-product align-right light-blue-background round-bottom\"\u003e\n\u003cdiv class=\"fade-section\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/products\/benchtop-laminar-flow-hood\"\u003e\u003cimg width=\"360\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-flow-hood-filter.jpg?width=360\u0026amp;height=400\u0026amp;crop=center\" loading=\"lazy\" height=\"400\" class=\"fade-element round-corners\" alt=\"Bench-friendly laminar flow hood\"\u003e \u003cimg width=\"360\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow-screen.jpg?width=360\u0026amp;height=400\u0026amp;crop=right\" loading=\"lazy\" height=\"400\" class=\"fade-element round-corners\" alt=\"Ossila laminar flow hood\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"featured-product-info\"\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/products\/benchtop-laminar-flow-hood\" class=\"h1\"\u003eOssila Laminar Flow Hood\u003c\/a\u003e\n\u003cp\u003eSet up a clean air environment in small-scale experiments with advanced sensor technology, a set of filters, and UV lighting included.\u003c\/p\u003e\n\u003cp\u003eThe interchangeable design can be set up in two different configurations: vertical and horizontal. Horizontal minimizes turbulence for enhanced sample protection, while vertical accommodates bulky equipment and reduces cross contamination.\u003c\/p\u003e\n\u003cp\u003eUsing a H13 grade HEPA filter to capture over 99.99% of all airborne particulates, easily achieve ISO Class 5 conditions. Maintain the clean workspace using live updates about the environment and filter saturation and software that operates the motor at an optimal speed, alerts you to upcoming filter changes, and warns you if the air flow changes.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ossila.com\/products\/benchtop-laminar-flow-hood\" class=\"featured-product-button\"\u003eBuy now\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"resources\"\u003eResources\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eBuying Guides\u003c\/h3\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-perovskite-case-study\"\u003e\u003cimg alt=\"Glove Box Perovskite Solar Cell Case Study\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/perovskite-glove-box-vs-air-square.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\" width=\"160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-perovskite-case-study\"\u003eCase Study: Perovskite Solar Cells in a Glove Box\u003c\/a\u003e\n\u003cp\u003eThe highest performing perovskite solar cells were all made in glove boxes. This case study to investigate how inert does an environment need to be for a given process and is the Ossila Glove Box effective.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-perovskite-case-study\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/sterile-ossila-laminar-flow-hood-contact-airflow\"\u003e\u003cimg src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/TS3N_7H_UP_COMPARISON.jpg?v=1694790207\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\" loading=\"lazy\" alt=\"Contamination Control: How Ossila Laminar Flow Hoods Perform\"\u003e\u003c\/a\u003e\u003ca href=\"\/pages\/sterile-ossila-laminar-flow-hood-contact-airflow\"\u003eContamination Control: How Ossila Laminar Flow Hoods Perform\u003c\/a\u003e\n\u003cp\u003eYou can test if the cleanliness of the air flow using settle plates and the surfaces using contact plates. To check that our laminar flow hood is suitable for microbiological uses, we tested for air and surface contamination.\u003c\/p\u003e\n\u003ca href=\"\/pages\/sterile-ossila-laminar-flow-hood-contact-airflow\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"buying-guide\" class=\"expandable\"\u003e\n\u003cdiv class=\"tile-container\" style=\"padding-top: 10px;\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-comparison\"\u003e\u003cimg alt=\"Why Buy the Ossila Glove Box\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glove-box-on-lab-bench.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\" width=\"160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-comparison\"\u003eWhy Buy the Ossila Glove Box\u003c\/a\u003e\n\u003cp\u003eIt is important for you to understand the benefits and limitations of different inert atmosphere systems before making the investment. If you are looking for a robust, easy-to-use system, the Ossila Glove Box is the perfect choice for you.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-comparison\"\u003eLearn more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-buying-guide\"\u003e\u003cimg alt=\"Ossila glove box on a lab bench\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Choosing-Glove-Box-dimensions.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\" width=\"160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-buying-guide\"\u003eHow to Choose a Glove Box\u003c\/a\u003e\n\u003cp\u003eChoosing the right glove box for your needs is important. The system should be suitable for your samples, experimental requirements, laboratory environment, and budget.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-buying-guide\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-application-notes\"\u003e\u003cimg alt=\"Glove Box Design\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Choosing-Glove-Box-materials.jpg?crop=center\u0026amp;width=160\u0026amp;height=160\" width=\"160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-application-notes\"\u003eDesigning a Glove Box\u003c\/a\u003e\n\u003cp\u003eThere are several important components to consider when designing a glove box. Importantly, they should be designed to reduce leakage as much as possible.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-application-notes\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/laminar-flow-hood-design\"\u003e\u003cimg alt=\"Laminar Flow Hood Design\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-laminar-flow-hood-screen-square.jpg?crop=center\u0026amp;width=160\u0026amp;height=160\" width=\"160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/laminar-flow-hood-design\"\u003eLaminar Flow Hood Design\u003c\/a\u003e\n\u003cp\u003eThe design of a laminar flow hood is critical to the quality of its performance. To optimize the performance, various design features must be considered and tested. Components such as the filter system, fan system, and structure greatly influence the air cleanliness, speed, and uniformity.\u003c\/p\u003e\n\u003ca href=\"\/pages\/laminar-flow-hood-design\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbutton class=\"anchor expand-link\" type=\"button\"\u003eView more resources\u003c\/button\u003e\u003c\/p\u003e\n\u003ch3\u003eMaintenance and Operation\u003c\/h3\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-operating-procedure\"\u003e\u003cimg alt=\"Glove Box Standard Operating Procedure\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-glove-box-in-laboratory.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-operating-procedure\"\u003eStandard Operating Procedure of a Glove Box\u003c\/a\u003e\n\u003cp\u003eWorking safely within a glove box requires the care and co-operation of everyone who uses it. For this reason, we recommend outlining a standard operating procedure for your laboratory.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-operating-procedure\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/laminar-flow-hood-cleaning-preparation\"\u003e\u003cimg alt=\"Laminar Flow Hood Cleaning Procedure\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Laminar_Flow_-_BACK_CLEANING_1.png?v=1694790207\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.ossila.com\/pages\/laminar-flow-hood-cleaning-preparation\"\u003e Laminar Flow Hood Cleaning Procedure\u003c\/a\u003e\n\u003cp\u003eRegular and thorough cleaning of your laminar flow hood allows you to reliably conduct your experiments without risk of contamination.\u003c\/p\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/laminar-flow-hood-cleaning-preparation\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"maintenance\" class=\"expandable\"\u003e\n\u003cdiv class=\"tile-container\" style=\"padding-top: 10px;\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-installation\"\u003e\u003cimg alt=\"Glove Box installation\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glovebox-gloves-placement-zoom.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-installation\"\u003eInstalling Your Glove Box\u003c\/a\u003e\n\u003cp\u003eThe Ossila Glove Box is designed to be easy to install and maintain, and is suitable for most laboratories. Its small footprint and quick set up also means that it is relatively portable and can be conveniently transferred between labs as required.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-installation\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/vertical-laminar-flow-hood-assembly\"\u003e\u003cimg alt=\"Glove Box installation\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/15-fix-filter-guard.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/vertical-laminar-flow-hood-assembly\"\u003eHow to Assemble the Vertical Laminar Flow Hood\u003c\/a\u003e\n\u003cp\u003eOur laminar flow hood arrives flat-packed. This gives you the flexibility to set up your unit in either a vertical or a horizontal configuration, and switch between configurations if needed.\u003c\/p\u003e\n\u003ca href=\"\/pages\/vertical-laminar-flow-hood-assembly\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/replace-glove-box-gloves\"\u003e\u003cimg alt=\"Replace glove box gloves\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glove-box-glove-change-step10.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\" width=\"160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/replace-glove-box-gloves\"\u003eHow to Replace Glove Box Gloves\u003c\/a\u003e\n\u003cp\u003eGlove box gloves must be flexible and relatively thin to allow movement within the main chamber. This will be the most vulnerable exposure point to air and moisture as small holes can easily occur here.\u003c\/p\u003e\n\u003ca href=\"\/pages\/replace-glove-box-gloves\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/laminar-flow-hood-filters\"\u003e\u003cimg alt=\"Replacing Your Laminar Flow Hood Filter\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/laminar-flow-hood-filter-square.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\" width=\"160\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.ossila.com\/pages\/laminar-flow-hood-filters\"\u003eReplacing Your Laminar Flow Hood Filter\u003c\/a\u003e\n\u003cp\u003eLaminar flow hoods use pre-filters and HEPA filters to create an environment with very low levels of contamination. It is important to know when and how to replace these filters, without risking contamination to the environment.\u003c\/p\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/laminar-flow-hood-filters\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-maintenance\"\u003e\u003cimg alt=\"Cleaning, Maintenance, And Troubleshooting: Glove Boxes\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glove-box-purge-inactive.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-electrical-feedthrough\"\u003eCleaning, Maintenance, And Troubleshooting: Glove Boxes\u003c\/a\u003e\n\u003cp\u003eThere are a number of steps that you as the glove box user can take to ensure that the inert atmosphere remains intact. It is also important to be able to quickly identify, troubleshoot, and fix problems as they occur.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-maintenance\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/getting-started-laminar-flow-hood\"\u003e\u003cimg alt=\"Getting Started with the Laminar Flow Hood\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Laminar-flow-hood-interface.png?v=1696931380\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.ossila.com\/pages\/getting-started-laminar-flow-hood\"\u003e Getting Started with the Laminar Flow Hood\u003c\/a\u003e\n\u003cp\u003eOssila laminar flow hoods are designed for effortless setup, user-friendly operation, and efficient control. This short video guide shows you how to get started with your new equipment.\u003c\/p\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/getting-started-laminar-flow-hood\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/outgassing-materials-glove-box\"\u003e\u003cimg alt=\"Glove Box installation\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-glovebox-front.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/outgassing-materials-glove-box\"\u003eOutgassing Materials and Solvents\u003c\/a\u003e\n\u003cp\u003eMaterials processed within a glove box can directly impact the quality of the atmosphere and the ability of the system to maintain an inert atmosphere.\u003c\/p\u003e\n\u003ca href=\"\/pages\/outgassing-materials-glove-box\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-electrical-feedthrough\"\u003e\u003cimg alt=\"Electrical feedthrough in the Ossila glove box\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/position-power-source-in-glovebox.jpg?width=160\u0026amp;height=160\u0026amp;crop=center5\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-electrical-feedthrough\"\u003eFeedthrough Assembly for Your Glove Box\u003c\/a\u003e\n\u003cp\u003eFeedthrough points allow you to pass lines and cables from the external to the internal environment. There are several different ways to create the required feedthroughs in your glove box.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-electrical-feedthrough\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-leaks\"\u003e\u003cimg alt=\"Glove Box Leaks\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Gloves-hole-glovebox.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-leaks\"\u003eLeaks in a Glove Box\u003c\/a\u003e\n\u003cp\u003eOur glove boxes run at an overpressure, so if the leak is small, the glove box may still be able to maintain the integrity of the internal atmosphere. However, during this time, the glove box will use a much larger amount of inert gas than normal as the overpressure in the glove box will result in a flow of gas from the inside of the system to the outside.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-leaks\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-leak-tests\"\u003e\u003cimg alt=\"Ossila glove box control panel when completing a leak test\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glove-box-leakage-test-settings.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-leak-tests\"\u003ePerforming Glove Box Leak Tests\u003c\/a\u003e\n\u003cp\u003eIf you suspect a leak, the first thing you should do is perform a leak test. Leak tests raise the glove box to an extreme positive or negative pressure and then measure the rate of change of pressure over a period of time.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-leak-tests\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbutton class=\"anchor expand-link\" type=\"button\"\u003eView more resources\u003c\/button\u003e\u003c\/p\u003e\n\u003ch3\u003eTheory and Applications\u003c\/h3\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/how-to-make-perovskites-solar-cells-in-a-glovebox-part-2\"\u003e\u003cimg alt=\"How to Make a Perovskites Solar Cells in a Glove Box\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Encapsulate-device-drop-epoxy-pipette.jpg?crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e\u003ca href=\"\/pages\/how-to-make-perovskites-solar-cells-in-a-glovebox-part-2\"\u003eHow to Make a Perovskites Solar Cells in a Glove Box\u003c\/a\u003e\n\u003cp\u003eThis video is a guide on how to make perovskite films when processed inside a nitrogen filled glove box. The resultant devices achieve efficiencies greater than 19% PCE.\u003c\/p\u003e\n\u003ca href=\"\/pages\/how-to-make-perovskites-solar-cells-in-a-glovebox-part-2\"\u003eLearn more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/pcr-in-laminar-flow-hoods\"\u003e\u003cimg alt=\"PCR in Laminar Flow Hoods\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/PCR-in-LFH-icon.png?v=1720520920\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e\u003ca href=\"\/pages\/pcr-in-laminar-flow-hoods\"\u003ePCR in Laminar Flow Hoods\u003c\/a\u003e\n\u003cp\u003ePCR is a process used to replicate DNA. It relies on a molecule called DNA polymerase, which can create a new DNA strand that matches a template strand.\u003c\/p\u003e\n\u003ca href=\"\/pages\/pcr-in-laminar-flow-hoods\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"theory\" class=\"expandable\"\u003e\n\u003cdiv class=\"tile-container\" style=\"padding-top: 10px;\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-applications\"\u003e\u003cimg alt=\"Glove Box Applications\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/spin-coater-inside-glove-box.jpg?crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-applications\"\u003eApplications of Glove Boxes\u003c\/a\u003e\n\u003cp\u003eA glove box is suitable for a variety of applications across the world of science and research. From organic electronics to additve manufacturing, the inert atmosphere provided by a glove box is critical in many settings.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-applications\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/laminar-flow-hoods-microbiology-molecular-biology-and-pharmaceuticals\"\u003e\u003cimg alt=\"Laminar Flow Hoods: Microbiology, Molecular Biology and Pharmaceuticals\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Horizontal-laminar-flow-hoods-agar-plates.jpg?v=1718720083\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e\u003ca href=\"\/pages\/laminar-flow-hoods-microbiology-molecular-biology-and-pharmaceuticals\"\u003eLaminar Flow Hoods: Microbiology, Molecular Biology and Pharmaceuticals\u003c\/a\u003e\n\u003cp\u003eTo maintain a clean and germ-free environment in a laboratory, it is a good idea to use a laminar flow hood.\u003c\/p\u003e\n\u003ca href=\"\/pages\/laminar-flow-hoods-microbiology-molecular-biology-and-pharmaceuticals\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/solar-cell-encapsulation\"\u003e\u003cimg alt=\"How to Make a Perovskites Solar Cells in A Glove Box\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/perovskite-photovoltaics.svg?width=160\u0026amp;height=160\u0026amp;crop=center\" width=\"160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/solar-cell-encapsulation\"\u003eSolar Cell Encapsulation in a Glove Box\u003c\/a\u003e\n\u003cp\u003eFilm and device encapsulation involves applying thin protective layers onto the surface of your electronic devices. Encapsulating your devices inside a glove box environment limits their exposure to contaminants\u003c\/p\u003e\n\u003ca href=\"\/pages\/solar-cell-encapsulation\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/spin-coating-in-laminar-flow-hood\"\u003e\u003cimg src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Spin-coating-lfh-lab-comparison.png?v=1715847044\" loading=\"lazy\" alt=\"Spin coating coated inside and outside a laminar flow hood - films have less and more defects respectively.\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/www.ossila.com\/pages\/spin-coating-in-laminar-flow-hood\"\u003e Spin Coating in Laminar Flow Hood\u003c\/a\u003e\n\u003cp\u003eTo achieve successful thin-film deposition via spin coating, it is crucial to minimize particle contamination. A vertical laminar flow hood can create a contamination free environment.\u003c\/p\u003e\n\u003ca href=\"https:\/\/www.ossila.com\/pages\/spin-coating-in-laminar-flow-hood\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/defining-moisture-content-in-a-glove-box\"\u003e\u003cimg alt=\"Argon vs Nitrogen for Glove Box\" height=\"160\" width=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Vapour_Phase_Evaporation.svg\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/defining-moisture-content-in-a-glove-box\"\u003eDefining Moisture Content in a Glove Box\u003c\/a\u003e\n\u003cp\u003eThere are multiple ways of defining how much moisture is present in the air. With clear definitions, guidance on converting values, and a simple conversion table, you will easily be able to work with any of the available definitions to control the moisture content in your glove box environment.\u003c\/p\u003e\n\u003ca href=\"\/pages\/defining-moisture-content-in-a-glove-box\"\u003eLearn more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/air-flow-in-laminar-flow-hoods\"\u003e\u003cimg alt=\"Air Flow in Laminar Flow Hoods\" height=\"160\" width=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/laminar-flow-hood-vertical-horizontal-design.svg?v=1691152534\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/air-flow-in-laminar-flow-hoods\"\u003eAir Flow in Laminar Flow Hoods\u003c\/a\u003e\n\u003cp\u003eAlthough the idea behind a laminar flow hood is simple, the implementation of a clean air flow is quite complex. The formation and preservation of optimal air flow characteristics within the hood are essential to maintain a contaminant-free workspace.\u003c\/p\u003e\n\u003ca href=\"\/pages\/air-flow-in-laminar-flow-hoods\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/argon-nitrogen-glove-box\"\u003e\u003cimg alt=\"Argon vs Nitrogen for Glove Box\" height=\"160\" width=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/argon-vs-nitrogen-price.png?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/argon-nitrogen-glove-box\"\u003eArgon vs Nitrogen for Glove Boxes\u003c\/a\u003e\n\u003cp\u003eArgon and nitrogen are both unreactive gases which can be used to create an inert environment within a glove box. Both gases will efficiently displace air within a confined space, are easy to store and will not react with most materials. Therefore, both N2 and Ar can create a glove box environment with very low moisture and oxygen levels.\u003c\/p\u003e\n\u003ca href=\"\/pages\/argon-nitrogen-glove-box\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/biological-safety-cabinets-laminar-flow-hoods\"\u003e\u003cimg alt=\"Biological Safety Cabinet vs Laminar Flow Hood\" height=\"160\" width=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Biological_Safety_Cabinet_vs_Laminar_Flow_Hood_Class_II.svg\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/biological-safety-cabinets-laminar-flow-hoods\"\u003eBiological Safety Cabinet vs Laminar Flow Hood\u003c\/a\u003e\n\u003cp\u003eWhile these pieces of equipment seem similar, their functions, applications, and design principles are different. This article offers a comprehensive comparison between both pieces of equipment, outlining their purposes and advantages.\u003c\/p\u003e\n\u003ca href=\"\/pages\/biological-safety-cabinets-laminar-flow-hoods\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/negative-vs-positive-glove-box-pressure\"\u003e\u003cimg alt=\"Positive pressure glove box with gloves inflated\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Glove_box_Correct_Arms.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/negative-vs-positive-glove-box-pressure\"\u003ePositive vs Negative Pressure in a Glove Box\u003c\/a\u003e\n\u003cp\u003eGlove boxes can be maintained at positive pressure or negative pressure. Both create atmospheres separate from ambient, keeping a barrier between your materials and the external lab environment.\u003c\/p\u003e\n\u003ca href=\"\/pages\/negative-vs-positive-glove-box-pressure\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/laminar-flow-hood-vs-glove-box\"\u003e\u003cimg alt=\"Laminar Flow Hood vs Glove Box\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Working-agar-plates-Ossila-laminar-flow-hood.jpg?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/laminar-flow-hood-vs-glove-box\"\u003eLaminar Flow Hood vs Glove Box\u003c\/a\u003e\n\u003cp\u003eA laminar flow hood and a glove box both provide controlled environments to be used in laboratory settings, but they have distinct differences in terms of their features and functions within the laboratory.\u003c\/p\u003e\n\u003ca href=\"\/pages\/laminar-flow-hood-vs-glove-box\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbutton class=\"anchor expand-link\" type=\"button\"\u003eView more resources\u003c\/button\u003e\u003c\/p\u003e\n\u003ch2 id=\"technical-support\"\u003eTechnical Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e[[contact]]\u003c\/p\u003e","products":[{"product_id":"glove-box","title":"Glove Box","description":"\u003ch2 id=\"product-oneliner\"\u003eAffordable Stainless Steel Glove Box for Your Workbench\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eUseful purge and test cycles managed by smart sensors and customizable software\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources\u003c\/a\u003e | \u003ca href=\"#technical-support\"\u003eTechnical Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eEasily create and maintain a low oxygen and moisture environment with this benchtop glove box. Handling, processing, and storing air sensitive samples, for chemistry and other inert atmosphere processing applications, is simple and convenient.\u003c\/p\u003e\n\u003cp\u003eAchieve oxygen levels as low as 0.5% and water levels as low as 0.1% relative humidity, then focus on your experiments and let the glove box handle the purging. Sophisticated software and high accuracy sensors trigger specially designed purge cycles and leak tests for extensive control with minimum effort. With a leak rate of less than 0.25% volume per hour, your chemicals, materials, and samples are safe for extended periods of time.\u003c\/p\u003e\n\u003cp\u003eImplement inert conditions in more of your experiments with universal feedthroughs for power, vacuums, and more. Once up and running, protect your experiments and reduce the need for a full system purge with live antechamber data and antechamber-specific purges.\u003c\/p\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"ISO class II glove box\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Glove_Box_key_Features__Air_Tight_1.svg?v=1720692404\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eISO Class II Leak Rate\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eStainless steel system for ultra-low\u003cbr\u003eleak rate of \u0026lt;0.25% vol\/hour\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Automated glove box purging\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Glove_Box_key_Features__Automated_purging.svg?v=1718707946\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eAutomated Purging\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eSmart sensors and purging software keep your inert gas costs low\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"High accuracy glove box sensors\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Accuracy.svg?v=1697194989\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eLive Sensor Feedback\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eHigh accuracy readings track oxygen, moisture, pressure, and temperature\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"LED light in glove box\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Processing_icons_Interchangeable.svg\" width=\"50\"\u003e\n\u003cp class=\"blue-heading text-center no-margin\"\u003eAntechamber Access\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eWith antechamber-specific purging to avoid costly workflow mistakes\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel panel-default\"\u003e\n\u003cdiv class=\"panel-body\"\u003e\n\u003ch3\u003eHow Effective is this Glove Box?\u003c\/h3\u003e\n\u003chr\u003e\n\u003cp\u003eGetting the essentials right, the Ossila Glove Box achieves oxygen levels below 0.5% and moisture levels as low as 15 ppm for high-performance inert conditions in a benchtop system. But is this enough compared to the more expensive, higher specification systems on the market?\u003c\/p\u003e\n\u003cp\u003eWhen fabricating perovskite thin films, we found no significant difference in device performance between films produced in the Ossila Glove Box and those made in a considerably more expensive, slightly higher specification system. The Ossila-produced devices achieved an impressive 19.2% champion efficiency, coming close to the 19.7% efficiency achieved with 0.1 ppm conditions. SEM images confirm both the resulting perovskite films were nearly identical, and were both drastically improved compared to films made in air.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg width=\"848\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-glove-box-perovskites-vs-competitor-air.png?heigjt=117\u0026amp;width=848\" loading=\"lazy\" height=\"177\" alt=\"SEM data for films prepared in the low price glove box, competing glove box, and air\"\u003e\n\u003cfigcaption\u003eSEM data of films prepared in three different processing environments (scale bar shows 1µm).\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eSo do you really need 0.1 ppm inert conditions in your research? In many applications an ISO class II system, like the Ossila Glove Box, provides robust inert conditions that are more than sufficient for success in your experiments. For a fraction of the price, it is a smart, cost-effective choice without sacrificing quality or results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure class=\"video\"\u003e\n  \u003cimg class=\"video-poster\" loading=\"lazy\" src=\"https:\/\/cdn.ossila.com\/videos\/Glovebox-product-over-view.jpg\" draggable=\"false\" height=\"675\" width=\"1200\"\u003e\n  \u003cvideo class=\"widescreen\" controls=\"controls\" controlslist=\"nodownload\" crossorigin=\"\" height=\"675\" width=\"1200\" preload=\"none\" title=\"Glove box overview\"\u003e\n\u003csource src=\"https:\/\/cdn.ossila.com\/videos\/Glovebox-product-over-view-1080p.mp4\" type=\"video\/mp4\"\u003e\n\u003ctrack default=\"\" kind=\"subtitles\" label=\"English\" src=\"https:\/\/cdn.ossila.com\/videos\/Glovebox-product-over-view.vtt\" srclang=\"en\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"Ossila Glove box product overview\",\n\"description\": \"Ossila Glove box product overview\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/Glovebox-product-over-view.jpg\",\n\"uploadDate\": \"2023-11-29\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/Glovebox-product-over-view-1080p.mp4\",\n\"duration\": \"PT1M09S\"\n}\n\u003c\/script\u003e\u003c\/figure\u003e\n\u003ch2 id=\"specification\"\u003eSpecifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eLeak Rate*\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;0.25% vol\/hour (ISO Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Input Pressure\u003c\/th\u003e\n\u003ctd\u003e2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWorking Overpressure Range\u003c\/th\u003e\n\u003ctd\u003e0.1 mbar – 5 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePurge Overpressure Range\u003c\/th\u003e\n\u003ctd\u003e10 mbar – 15 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"text-muted\"\u003e*For an inert atmosphere system, a leak rate of between 0.05 to 0.5% of box volume per hour is sufficiently low.\u003c\/p\u003e\n\u003ch3\u003eAutomated Purge Cycles\u003c\/h3\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 text-center\"\u003e\n\u003cimg alt=\"Automated purging glove box system\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Automated_Purge.svg?v=1688564222\" width=\"50\"\u003e\n\u003cp class=\"text-center blue-heading\"\u003eAutomated Purging\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eWhen active, the system will purge as needed to maintain low oxygen and water levels without excessive use of inert gas.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 text-center\"\u003e\n\u003cimg alt=\"Integrated glove box leak tests\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Leak_Test.svg?v=1688564383\" width=\"50\"\u003e\n\u003cp class=\"blue-heading text-center\"\u003eLeak Test\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eQuickly and accurately identify leaks by monitoring the internal pressure through a simple, pre-programmed leak test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 text-center\"\u003e\n\u003cimg alt=\"Quick glove box purge\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Quick_Purge.svg?v=1688564443\" width=\"50\"\u003e\n\u003cp class=\"blue-heading text-center\"\u003eQuick Purge\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eCirculate fresh gas for a short period of time to maintain a clean environment, even if monitored levels are unchanged.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 text-center\"\u003e\n\u003cimg alt=\"Inital glove box purge\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Initial_Purge.svg?v=1688564511\" width=\"50\"\u003e\n\u003cp class=\"blue-heading text-center\"\u003eInitial Purge\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eAfter installation or significant exposure, achieve desired moisture, oxygen, and pressure levels within 24 hours.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 text-center\"\u003e\n\u003cimg alt=\"Circulation glove box purge\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Circulation_Purge.svg?v=1688564578\" width=\"50\"\u003e\n\u003cp class=\"blue-heading text-center\"\u003eCirculation Purge\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eAn automated short circulation purge once a day keeps the system fresh. Customize the time to suit your lab.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-4 text-center\"\u003e\n\u003cimg alt=\"Glove box antechamber cycle\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Antechamber_Purge.svg?v=1688564630\" width=\"50\"\u003e\n\u003cp class=\"blue-heading text-center\"\u003eAntechamber Cycle\u003c\/p\u003e\n\u003cp class=\"text-center\"\u003eStart an antechamber purge easily to ensure bringing materials into or out of the glove box is safe and simple.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eEnvironmental Sensors\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eOxygen Sensor Range\u003c\/th\u003e\n\u003ctd\u003e0.5% – 25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eOxygen Sensor Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMoisture Sensor Range\u003c\/th\u003e\n\u003ctd\u003e0% relative humidity – 100% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMoisture Sensor Resolution\u003c\/th\u003e\n\u003ctd\u003e0.1% relative humidity (15 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePressure Sensor Range\u003c\/th\u003e\n\u003ctd\u003e300 mbar – 1200 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePressure Sensor Resolution\u003c\/th\u003e\n\u003ctd\u003e0.005 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eTemperature Sensor Range\u003c\/th\u003e\n\u003ctd\u003e40 °C – 120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eTemperature Sensor Resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMain Chamber, External (D x W x H)\u003c\/th\u003e\n\u003ctd\u003e500 mm x 750 mm x 500 mm (19.7\" x 29.5\" x 19.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMain Chamber, Internal (D x W x H)\u003c\/th\u003e\n\u003ctd\u003e450 mm x 600 mm x 500 mm (17.7\" x 23.6\" x 19.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAntechamber, Internal (D x W x H)\u003c\/th\u003e\n\u003ctd\u003e150 mm x 150 mm x 150 mm (5.9\" x 5.9\" x 5.9\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e33.85 kg (74.63 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003ca href=\"#specifications-continued\"\u003eView more specifications\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eBuilt for Every Laboratory\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Glove box interface display\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-glove-box-front-square.jpg?v=1687789789\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eMonitor Internal Conditions\u003c\/p\u003e\n\u003cp\u003eGuarantee your inert environment with precision sensor boards which track real-time oxygen, moisture, pressure, and temperature levels. Using the high accuracy readings, automated purge cycles respond to environmental changes so you can stay focused on your work with full confidence that your samples are protected.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Glove box accessories\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/inside-ossila-glove-box-square.jpg?width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eLower Ingress than Acrylic\u003c\/p\u003e\n\u003cp\u003eChoose a glove box built for performance and integrity. Grade 304 stainless steel, 6 mm hardened glass, and butyl rubber gloves ensure ultra-low moisture and oxygen ingress rates, exceeding acrylic alternatives. Designed to withstand frequent, long-term use, you can safely work with a range of materials in many applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"Glove box\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Air-Free-Processing-Glove-Box-Square.jpg?width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eCheap to Run\u003c\/p\u003e\n\u003cp\u003eSet up a reliable inert environment without a huge initial investment or high maintenance costs. Compared to larger systems, low ingress rates and a small volume significantly reduce the amount of gas you need to protect your samples and processes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"Glove box feedthrough\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/lights-on-glove-box-square.jpg?width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eUniversal Feedthroughs\u003c\/p\u003e\n\u003cp\u003eExpand your experimental possibilities and set up a range of equipment inside the glove box. Easily connect power, communication lines, or vacuum systems, without compromising the controlled environment, using the two universal KF 40 flange feedthroughs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"Glove box control panel menu\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-glove-box-software-square.jpg?v=1687792935\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eEasy-To-Use Software\u003c\/p\u003e\n\u003cp\u003eCustomize and monitor your inert environment with the integrated software. It is easy to set your desired conditions, measure oxygen and moisture levels, trigger or schedule a purge, confirm when the antechamber is safe to open, test for leaks, and check if the system is still running at the desired overpressure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eGlove Box Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track\"\u003e\n\u003ca class=\"carousel-item\" title=\"The Ossila Glove Box\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/lights-on-glove-box.jpg\"\u003e \u003cimg alt=\"The Ossila Glove Box\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/lights-on-glove-box.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca title=\"User-friendly glove box interface\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-glove-box-software.jpg\"\u003e \u003cimg alt=\"User-friendly glove box interface\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-glove-box-software.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca title=\"Antechamber glove box access\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-glove-box.png\"\u003e \u003cimg alt=\"Antechamber glove box access\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/ossila-glove-box.png?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca title=\"Glove Box in use\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/using-the-ossila-glove-box.png\"\u003e \u003cimg alt=\"Glove Box in use\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/using-the-ossila-glove-box.png?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca title=\"Positive pressure glove box gloves\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glove-box-arms.jpg\"\u003e \u003cimg alt=\"Positive pressure glove box gloves\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glove-box-arms.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca role=\"button\" class=\"carousel-left-control\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-left\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious \u003c\/span\u003e\u003c\/a\u003e \u003ca role=\"button\" class=\"carousel-right-control\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-right\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext \u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"specifications-continued\"\u003eAdditional Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure\u003e\u003cimg alt=\"Glove box wireframe\" height=\"452\" width=\"598\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Product_Wireframes_Glove_Box.svg\"\u003e\u003c\/figure\u003e\n\u003ch3\u003eMaterials\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eBox and Antechamber\u003c\/th\u003e\n\u003ctd\u003e2 mm (0.08\") graded 304 stainless steel, 2B surface finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWindow\u003c\/th\u003e\n\u003ctd\u003e6 mm (0.24\") hardened glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eGloves\u003c\/th\u003e\n\u003ctd\u003e2 x butyl rubber gloves, 8\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOther Features\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFeedthroughs\u003c\/th\u003e\n\u003ctd\u003e2 x DN 40 ISO-KF blanked feedthroughs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eGas Inlet \/ Exhaust*\u003c\/th\u003e\n\u003ctd\u003e12 mm (0.47\") push-fit connector (PTFE recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eGas Inlet Requirements\u003c\/th\u003e\n\u003ctd\u003e99.99% N\u003csup\u003e2\u003c\/sup\u003e purity, inlet pressure (1 bar to 2 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSafety Features\u003c\/th\u003e\n\u003ctd\u003eSoftware control of maximum pressure, 500 mbar blow off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eLighting\u003c\/th\u003e\n\u003ctd\u003eInternal LED white light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"text-muted\"\u003e*The exhaust does not have filtration and so should be exhausted into a fumehood or exhaust stack of the building.\u003c\/p\u003e\n\u003ch3\u003eDocuments and Datasheets\u003c\/h3\u003e\n\u003cp class=\"pad-top-half-height\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Glovebox-Purge-Time.jpg\" target=\"_blank\"\u003e\u003cimg alt=\"Glove box leak rate tests\" height=\"20\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px; height: 22px;\" width=\"20\"\u003ePurge Time Graph (Representative graph of the purge time for the main chamber)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pad-top-half-height\"\u003e\u003ca href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Glovebox-Leak-Rate.jpg\" target=\"_blank\"\u003e\u003cimg alt=\"Glove box leak rate tests\" height=\"20\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px; height: 22px;\" width=\"20\"\u003eLeak Rate Tests (representative graph of the leak rate of a system, JPG)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pad-top-half-height\"\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/documentation\/glove-box-declaration-of-conformity.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"Glove box Declaration of Conformance\" height=\"22\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px; height: 22px;\" width=\"20\"\u003eDeclaration of Conformance (EMC Directive, RoHS Directive)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"pad-top-half-height\"\u003e\u003ca href=\"https:\/\/downloads.ossila.com\/manuals\/glove-box-v1_1.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"Glove box manual\" height=\"22\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/icon-manual.svg\" style=\"margin-right: 12px; height: 22px;\" width=\"20\"\u003eOssila Glove Box User Manual (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-comparison\"\u003e\u003cimg alt=\"Why Buy the Ossila Glove Box\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glove-box-antechamber.jpg?v=1625493069\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-comparison\"\u003e Why Buy the Ossila Glove Box\u003c\/a\u003e\n\u003cp\u003eOur system is robust, affordable, and easy-to-use. It creates an inert environment suitable for many applications.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-comparison\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-buying-guide\"\u003e\u003cimg alt=\"How to choose a glove box\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/using-the-ossila-glove-box.png?crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-buying-guide\"\u003e How to Choose a Glove Box\u003c\/a\u003e\n\u003cp\u003eConsider these six factors to choose the most suitable system for your samples, experimental needs, budget, and lab environment.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-buying-guide\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Type B (US)","offer_id":31883394875488,"sku":"L2007A1-US","price":6950.0,"currency_code":"GBP","in_stock":true},{"title":"Type F (EU)","offer_id":31883394842720,"sku":"L2007A1-EU","price":6950.0,"currency_code":"GBP","in_stock":true},{"title":"Type G (UK)","offer_id":31883394809952,"sku":"L2007A1-UK","price":6950.0,"currency_code":"GBP","in_stock":true},{"title":"Type I (AU)","offer_id":31883394908256,"sku":"L2007A1-AU","price":6950.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/glove-box-product-image.jpg?v=1747644248"},{"product_id":"hepa-filters","title":"HEPA Filters for Laminar Flow Hoods and Clean Rooms","description":"\u003ch2 id=\"product-oneliner\"\u003eReplacement HEPA Filters for Clean Rooms and Laminar Flow Hoods\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eCapture up to 99.99% of particulates for ISO Class 5 air cleanliness\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#specification\"\u003eFilter Size\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#related\"\u003eRelated Products\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eH13 grade HEPA filters to capture up to 99.99% of particulates from the air before it enters your workspace. This grade of filter can achieve air cleanliness values of ISO Class 5, providing a working environment with a minimal amount of particulate contamination.\u003c\/p\u003e\n\u003cp\u003eOur HEPA filters are available in several different sizes and are compatible with our \u003ca title=\"Interchangeable benchtop system\" href=\"\/products\/benchtop-laminar-flow-hood\"\u003elaminar flow hood\u003c\/a\u003e, as well as with clean rooms and other brands of laminar flow hood.\u003c\/p\u003e\n\u003ch2 id=\"specification\"\u003eHEPA Filter Sizes\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFilter Size\u003c\/th\u003e\n\u003cth\u003eFiltration Rate\u003c\/th\u003e\n\u003cth\u003eRated Air Flow (m\u003csup\u003e3\u003c\/sup\u003e\/h)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e610 mm x 610 mm x 50 mm\u003c\/td\u003e\n\u003ctd\u003e99.99%\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e915 mm x 610 mm x 50 mm\u003c\/td\u003e\n\u003ctd\u003e99.99%\u003c\/td\u003e\n\u003ctd\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1220 mm x 610 mm x 50 mm\u003c\/td\u003e\n\u003ctd\u003e99.99%\u003c\/td\u003e\n\u003ctd\u003e900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIf the size or grade of filter that you are looking for is not listed above, please contact us to make an enquiry. We are able to source a wide variety of filter materials and may be able to help with your filtration needs.\u003c\/p\u003e\n\n\u003cfigure\u003e\u003cimg alt=\"HEPA Filters for Laminar Flow Hoods and Clean Rooms Size\" height=\"452\" width=\"598\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/hepa-filters-size.svg\"\u003e\u003c\/figure\u003e\n\n\u003ch2 id=\"gallery\"\u003eHEPA Filter Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca title=\"Vertical laminar flow hood\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-flow-hood-filter.jpg?width=1024\"\u003e \u003cimg alt=\"Vertical laminar flow hood\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-flow-hood-filter.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" title=\"Horizontal laminar flow hood filter\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow-hood-filter.jpg?width=1024\"\u003e \u003cimg alt=\"Horizontal laminar flow hood filter\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow-hood-filter.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca title=\"Filter in vertical laminar flow hood\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/HEPA-Filters.jpg?width=1024\"\u003e \u003cimg alt=\"Filter in vertical laminar flow hood\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/HEPA-Filters.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e \u003ca title=\"Horizontal laminar flow hood\" class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow-screen.jpg?width=1024\"\u003e \u003cimg alt=\"Horizontal laminar flow hood\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow-screen.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" loading=\"lazy\" height=\"280\" width=\"420\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca role=\"button\" class=\"carousel-left-control\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-left\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u0026gt;\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious\u003c\/span\u003e \u003c\/a\u003e \u003ca role=\"button\" class=\"carousel-right-control\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-right\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"related\"\u003eRelated Products\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eTo extend the useful life and efficiency of your HEPA filter, we always recommend using a laminar flow hood pre-filter. Passing the air through a pre-filter prevents larger particulates from reaching (and subsequently clogging) your HEPA filter.\u003c\/p\u003e\n\u003cp\u003e[[collection handle=\"equipment-accessories\" tags=\"laminar flow hood\"]]\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/laminar-flow-hood-filters\"\u003e \u003cimg width=\"160\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/13-LFH-Use-screws-to-fix-filters.jpg?v=16956497427\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\" loading=\"lazy\" height=\"160\" alt=\"Lamianr flow hood HEPA filter\"\u003e \u003c\/a\u003e \u003ca href=\"\/pages\/laminar-flow-hood-filters\"\u003e Replacing Your Laminar Flow hood Filter\u003c\/a\u003e\n\u003cp\u003eIt is important to know when and how to replace your laminar flow hood filters, without risking contamination to the environment.\u003c\/p\u003e\n\u003ca href=\"\/pages\/laminar-flow-hood-filters\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"HEPA Filter (H13) \/ 610 mm x 610 mm x 50 mm \/ One","offer_id":42901883289816,"sku":"L2008-H13-A-1","price":165.0,"currency_code":"GBP","in_stock":true},{"title":"HEPA Filter (H13) \/ 610 mm x 610 mm x 50 mm \/ Five","offer_id":43883548049624,"sku":"L2008-H13-A-5","price":660.0,"currency_code":"GBP","in_stock":true},{"title":"HEPA Filter (H13) \/ 915 mm x 610 mm x 50 mm \/ One","offer_id":42902191702232,"sku":"L2008-H13-B-1","price":250.0,"currency_code":"GBP","in_stock":true},{"title":"HEPA Filter (H13) \/ 915 mm x 610 mm x 50 mm \/ Five","offer_id":43883548082392,"sku":"L2008-H13-B-5","price":1000.0,"currency_code":"GBP","in_stock":false},{"title":"HEPA Filter (H13) \/ 1220 mm x 610 mm x 50 mm \/ One","offer_id":42902151528664,"sku":"L2008-H13-C-1","price":330.0,"currency_code":"GBP","in_stock":true},{"title":"HEPA Filter (H13) \/ 1220 mm x 610 mm x 50 mm \/ Five","offer_id":43883548115160,"sku":"L2008-H13-C-5","price":1300.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/hepa-filters-product-photo.jpg?v=1759223440"},{"product_id":"glove-box-accessories","title":"Glove Box Gloves","description":"\u003ch2 id=\"product-oneliner\"\u003eReplacement Butyl Rubber Gloves\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eCompatible with the Ossila Glove Box\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eHigh quality replacement glove box gloves for the Ossila \u003ca href=\"https:\/\/www.ossila.com\/products\/glove-box\" title=\"Low price, benchtop system\"\u003eGlove Box\u003c\/a\u003e or any other with 8\" glove ports. Glove box gloves are susceptible to damage from everyday use and one of the most common sources of glove box leaks. Occasionally, you may therefore need to replace your gloves with a new pair. Butyl rubber gloves are the best choice for inert atmosphere environment due to their extremely low permeability to moisture and oxygen ingress. At the same time, they provide high resistance to a wide range of chemicals. At 0.38 mm thick, our glove box gloves are highly flexible, so you can maintain good manual dexterity.\u003c\/p\u003e\n\u003cp\u003eGlove boxes are often used to handle air-sensitive materials that require an inert atmosphere, but they also serve to protect the user from physical exposure to the materials. If you are working with dangerous goods, we recommend wearing disposable gloves inside the glove box gloves as an extra precaution. This will also make your glove box gloves last longer.\u003c\/p\u003e\n\u003ch2 class=\"no-margin\" id=\"specification\"\u003eSpecification\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eGlove Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eButyl Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eGlove Finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eGlove Thickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mil (0.38 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eGlove Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eGlove Port Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eGlove Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"38.2%\"\u003e\u003cstrong\u003eGlove Handedness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbidextrous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"gallery\"\u003eGlove Box Gloves Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003cfigure\u003e\u003cimg alt=\"Replacing glove box gloves\" height=\"565\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glove-box-glove-change-step10.jpg?v=1667897091\u0026amp;width=848\u0026amp;height=565\" width=\"848\"\u003e\u003c\/figure\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-operating-procedure\"\u003e\u003cimg alt=\"Glove Box Standard Operating Procedure\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glove-box-antechamber.jpg?v=1625493069\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-operating-procedure\"\u003e Glove Box Standard Operating Procedure\u003c\/a\u003e\n\u003cp\u003eWorking safely within an inert atmosphere glove box requires the care and co-operation of everyone who uses it. For this reason, we recommend outlining a standard operating procedure for your laboratory.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-operating-procedure\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-installation\"\u003e\u003cimg alt=\"Glove Box installation\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glovebox-gloves-placement-zoom.jpg?v=1667832953\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-installation\"\u003e Glove Box Installation\u003c\/a\u003e\n\u003cp\u003eThe Ossila Glove Box is designed to be easy to install and maintain, and is suitable for most laboratories. Its small footprint and quick set up also means that it is relatively portable and can be conveniently transferred between labs as required.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-installation\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"card-box\"\u003e\n\u003ch3 class=\"h4\"\u003eHow to Replace Glove Box Gloves\u003c\/h3\u003e\n\u003cp\u003eGloves used in a glove box must be flexible and relatively thin to allow movement within the main chamber. However, they must also provide adequate ingression protection. Therefore, the glove box gloves will be the most vulnerable exposure point within your glove box as small holes and tears can easily occur.\u003c\/p\u003e\n\u003ca href=\"\/pages\/replace-glove-box-gloves\"\u003eLearn more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Default Title","offer_id":43165658317016,"sku":"L2007A1-E3","price":420.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/Glove-Box-Gloves.png?v=1753442029"},{"product_id":"glove-box-o-rings","title":"Glove Box Nitrile O-Rings","description":"\u003ch2 id=\"product-oneliner\"\u003eReplacement Nitrile O-rings for the Ossila Glove Box\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eFull set of O-rings that offer great air sealing\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eGlove Port O-Rings\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eThe glove port O-ring kit provides you with a full set of replacement O-rings for securing your gloves to the Ossila \u003ca href=\"\/products\/glove-box\" title=\"ISO Class II system\"\u003eGlove Box\u003c\/a\u003e. Each O-ring is specifically sized to allow for a tight secure fit on the glove port ensuring the gloves remain in place. Each kit comes with 4 O-rings, allowing you to use 2 for each port.\u003c\/p\u003e\n\u003ch2 class=\"no-margin\" id=\"specification\"\u003eSpecification\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable class=\"no-border\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"no-border\" width=\"38.2%\"\u003e\u003cstrong\u003eO-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"no-border\"\u003eNitrile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"no-border\" width=\"38.2%\"\u003e\u003cstrong\u003eO-Ring Thickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"no-border\"\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"no-border\" width=\"38.2%\"\u003e\u003cstrong\u003eO-Ring diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"no-border\"\u003e185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"no-border\" width=\"38.2%\"\u003e\u003cstrong\u003eQuantity in Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"no-border\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eAntechamber Door O-Rings\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eThe antechamber door O-ring kit is a set of replacement O-rings for the antechamber doors on the Ossila Laboratory Glove Box. Each O-ring is specifically sized for the doors, while the hardness ensures a complete seal across the face. Each kit comes with 2 O-rings, allowing you to replace the seals on both doors.\u003c\/p\u003e\n\u003ch2 class=\"no-margin\" id=\"specification\"\u003eSpecification\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable class=\"no-border\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"no-border\" width=\"38.2%\"\u003e\u003cstrong\u003eO-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"no-border\"\u003eNitrile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"no-border\" width=\"38.2%\"\u003e\u003cstrong\u003eO-Ring Thickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"no-border\"\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"no-border\" width=\"38.2%\"\u003e\u003cstrong\u003eO-Ring Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"no-border\"\u003e\u003cspan\u003e208 mm or 198 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"no-border\" width=\"38.2%\"\u003e\u003cstrong\u003eQuantity in Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"no-border\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cfigure\u003e\u003cimg alt=\"Glove Box Nitrile O-Rings, Serial number 0068 and earlier, serial number 0069 and onward\" class=\"fill\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Ossila-O-Ring-Comparrison.jpg?v=1716291228\" width=\"848\"\u003e\n\u003cfigcaption\u003e198mm (left) for Glove Box serial numbers 0069 and onwards, 208 (right) for serial numbers 0068 and earlier\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-operating-procedure\"\u003e\u003cimg alt=\"Glove Box Standard Operating Procedure\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glove-box-antechamber.jpg?v=1625493069\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-operating-procedure\"\u003e Glove Box Standard Operating Procedure\u003c\/a\u003e\n\u003cp\u003eWorking safely within an inert atmosphere glove box requires the care and co-operation of everyone who uses it. For this reason, we recommend outlining a standard operating procedure for your laboratory.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-operating-procedure\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-installation\"\u003e\u003cimg alt=\"Glove Box Installation\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glovebox-gloves-placement-zoom.jpg?v=1667832953\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-installation\"\u003e Glove Box Installation\u003c\/a\u003e\n\u003cp\u003eThe Ossila Glove Box is designed to be easy to install and maintain, and is suitable for most laboratories. Its small footprint and quick set up also means that it is relatively portable and can be conveniently transferred between labs as required.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-installation\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box\"\u003e\n\u003ch3 class=\"h4\"\u003eHow to Replace Glove Box Gloves\u003c\/h3\u003e\n\u003cp\u003eGloves used in a glove box must be flexible and relatively thin to allow movement within the main chamber. However, they must also provide adequate ingression protection. Therefore, the glove box gloves will be the most vulnerable exposure point within your glove box as small holes and tears can easily occur.\u003c\/p\u003e\n\u003ca href=\"\/pages\/replace-glove-box-gloves\"\u003eLearn more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Glove Port O-Ring (Pack of 4) \/ 185 mm for all Ossila Glove Boxes","offer_id":43490625913048,"sku":"L2007A1-E1","price":16.0,"currency_code":"GBP","in_stock":true},{"title":"Antechamber O-Ring (Pack of 2) \/ 198 mm for serial numbers 0069 onwards","offer_id":43490625945816,"sku":"L2007A1-E2-198","price":10.5,"currency_code":"GBP","in_stock":true},{"title":"Antechamber O-Ring (Pack of 2) \/ 208 mm for serial numbers 0068 and earlier","offer_id":44974488355032,"sku":"L2007A1-E2-208","price":10.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/nitrile-o-ring-glove-port-product-photo.jpg?v=1757408780"},{"product_id":"oxygen-sensor","title":"Oxygen Sensor","description":"\u003ch2 id=\"product-oneliner\"\u003eReplacement Oxygen Sensor\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eReplaceable oxygen sensor for the Ossila Glove Box\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eThe oxygen sensor that is part of the Ossila \u003ca href=\"\/products\/glove-box\" title=\"Low price, inert system\"\u003eGlove Box\u003c\/a\u003e sensor board requires occasional replacement due to the shelf life of the emitting material used within the photoluminescence sensor. These simple to replace sensors can be purchased to switch out from your sensor boards when it is time to replace them.\u003c\/p\u003e\n\u003ch2 class=\"no-margin\" id=\"specification\"\u003eSpecification\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable class=\"no-border\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"no-border\" width=\"38.2%\"\u003e\u003cstrong\u003eOxygen Sensor Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"no-border\"\u003e0.5% to 25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"no-border\" width=\"38.2%\"\u003e\u003cstrong\u003eOxygen Sensor Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"no-border\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"no-border\" width=\"38.2%\"\u003e\u003cstrong\u003eSensor Board Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"no-border\"\u003e4-Pin Mounting Sockets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-operating-procedure\"\u003e\u003cimg alt=\"Glove Box Standard Operating Procedure\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glove-box-antechamber.jpg?v=1625493069\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-operating-procedure\"\u003e Glove Box Standard Operating Procedure\u003c\/a\u003e\n\u003cp\u003eWorking safely within an inert atmosphere glove box requires the care and co-operation of everyone who uses it. For this reason, we recommend outlining a standard operating procedure for your laboratory.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-operating-procedure\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/glove-box-installation\"\u003e\u003cimg alt=\"Glove Box installation\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/glovebox-gloves-placement-zoom.jpg?v=1667832953\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\"\u003e\u003c\/a\u003e \u003ca href=\"\/pages\/glove-box-installation\"\u003e Glove Box Installation\u003c\/a\u003e\n\u003cp\u003eThe Ossila Glove Box is designed to be easy to install and maintain, and is suitable for most laboratories. Its small footprint and quick set up also means that it is relatively portable and can be conveniently transferred between labs as required.\u003c\/p\u003e\n\u003ca href=\"\/pages\/glove-box-installation\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Default Title","offer_id":43488470499544,"sku":"L2007A1-E4","price":200.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/glove-box-oxygen-sensor-product-image.jpg?v=1754390649"},{"product_id":"laminar-flow-hood-pre-filters","title":"Laminar Flow Hood Pre-Filters","description":"\u003ch2 id=\"product-oneliner\"\u003eReplacement Laminar Flow Hood Pre-Filters\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eCapture large particles and improve the filtration of you laminar flow hood\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#specification\"\u003eFilter Size\u003c\/a\u003e | \u003ca href=\"#related\"\u003eRelated Products\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eProlong the life of your more expensive HEPA or UPLA filter with pre-filters that prevent them from becoming saturated by large particulates.\u003c\/p\u003e\n\u003cp\u003eOur \u003ca title=\"Full equipped system\" href=\"\/products\/benchtop-laminar-flow-hood\"\u003elaminar flow hood\u003c\/a\u003e pre-filters can be purchased either in pre-cut sheets for quick and easy replacement or on the roll in bulk to save you money on your laminar flow maintenance. Rated to F5 filtration class, these filters trap around 95% of particulates, with a high capture rate for larger particulates.\u003c\/p\u003e\n\u003ch2 id=\"specification\"\u003ePre-Filter Sizes\u003c\/h2\u003e\n\u003chr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFilter Size\u003c\/th\u003e\n\u003cth\u003eFiltration Rate\u003c\/th\u003e\n\u003cth\u003eProduct Code\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e150 mm Diameter Disc x 5\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;60% (\u0026gt;1 µm)\u003c\/td\u003e\n\u003ctd\u003eL2008-F5-A-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e150 mm Diameter Disc x 10\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;60% (\u0026gt;1 µm)\u003c\/td\u003e\n\u003ctd\u003eL2008-F5-A-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 mm Wide Sheet\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;60% (\u0026gt;1 µm)\u003c\/td\u003e\n\u003ctd\u003eL2008-F5-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePlease contact us to enquire about other grades or sizes of filter. We are able to source a wide variety of filter materials and may be able to help with your filtration needs.\u003c\/p\u003e\n\u003ch2 id=\"related\"\u003eRelated Products\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003eA laminar flow hood uses a two-stage filtration. After the air is passed through the pre-filter, a secondary high efficiency filter captures the remaining particulates.\u003c\/p\u003e\n\u003cp\u003e[[collection handle=\"equipment-accessories\" tags=\"laminar flow hood\"]]\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/laminar-flow-hood-filters\"\u003e \u003cimg width=\"160\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/13-LFH-Use-screws-to-fix-filters.jpg?v=16956497427\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\" loading=\"lazy\" height=\"160\" alt=\"Replacing Your Laminar Flow hood Filter\"\u003e \u003c\/a\u003e \u003ca href=\"\/pages\/laminar-flow-hood-filters\"\u003eReplacing Your Laminar Flow hood Filter\u003c\/a\u003e\n\u003cp\u003eIt is important to know when and how to replace your laminar flow hood filters, without risking contamination to the environment.\u003c\/p\u003e\n\u003ca href=\"\/pages\/laminar-flow-hood-filters\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/how-does-hepa-filter-work\"\u003e \u003cimg width=\"160\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/HEPA_Filter_Work.png?v=1694700026\u0026amp;crop=center\u0026amp;width=160\u0026amp;height=160\" loading=\"lazy\" height=\"160\" alt=\"HEPA Filter: What Is It and How Does It Work?\"\u003e \u003c\/a\u003e \u003ca href=\"\/pages\/how-does-hepa-filter-work\"\u003e HEPA Filter: What Is It and How Does It Work?\u003c\/a\u003e\n\u003cp\u003eThe acronym HEPA stands for High Efficiency Particulate Air, and these filters boast an exceptional ability to achieve a high standard of particle filtration.\u003c\/p\u003e\n\u003ca href=\"\/pages\/how-does-hepa-filter-work\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ossila","offers":[{"title":"Pre-Filter (F5) \/ 150 mm Diameter Disc (Pack of 5)","offer_id":43883403772120,"sku":"L2008-F5-A-5","price":22.0,"currency_code":"GBP","in_stock":true},{"title":"Pre-Filter (F5) \/ 150 mm Diameter Disc (Pack of 10)","offer_id":43883403804888,"sku":"L2008-F5-A-10","price":38.0,"currency_code":"GBP","in_stock":true},{"title":"Pre-Filter (F5) \/ 1000 mm Wide Sheet (per\/m)","offer_id":43883403837656,"sku":"L2008-F5-B","price":33.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/laminar-flow-hood-pre-filters-product-photo.jpg?v=1742381062"},{"product_id":"benchtop-laminar-flow-hood","title":"Laminar Flow Hood","description":"\u003ch2 id=\"product-oneliner\"\u003eFully Equipped as Standard for Benchtop Experiments\u003c\/h2\u003e\n\u003cp class=\"text-center\"\u003eWith advanced sensor technology, set of filters, stainless steel tray, and UV lighting\u003c\/p\u003e\n\u003chr\u003e\n\u003cp class=\"text-center\"\u003e\u003ca href=\"#overview\"\u003eOverview\u003c\/a\u003e | \u003ca href=\"#specification\"\u003eSpecifications\u003c\/a\u003e | \u003ca href=\"#features\"\u003eFeatures\u003c\/a\u003e | \u003ca href=\"#gallery\"\u003eGallery\u003c\/a\u003e | \u003ca href=\"#included\"\u003eIn the Box\u003c\/a\u003e | \u003ca href=\"#accessories\"\u003eAccessories\u003c\/a\u003e | \u003ca href=\"#resources\"\u003eResources and Support\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp id=\"overview\"\u003eSet up a clean air environment for working with sensitive samples in small-scale experiments. The Ossila Laminar Flow Hood is a simple-to-use, benchtop system designed to easily integrate uniform air flow into your lab capabilities.\u003c\/p\u003e\n\u003cp\u003eUnlike many other laminar flow hoods, the system is fully equipped as standard with a HEPA filter, pre-filter, environmental sensors, control interface, UV light, and tray. Plus, the flat-pack design means you can assemble the hood according to your experimental needs:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn the horizontal orientation, achieve clean laminar air flow with minimal turbulence for enhanced sample protection against external contamination.\u003c\/li\u003e\n\u003cli\u003eThe vertical orientation can accommodate bulky equipment and reduces cross contamination between samples that are easily disturbed, like powders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"row display-flex\"\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Vertical laminar flow hood for uniform air flow\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Uniform_Air_Flow.svg?v=1697547593\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eUniform Air Flow\u003c\/p\u003e\n\u003cp\u003e510 m\u003csup\u003e3\u003c\/sup\u003ehour\u003csup\u003e-1\u003c\/sup\u003e with pressure sensors\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Choose between the vertical or horizontal configuration\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Low_Maintenance.svg?v=1697616401\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eChoose Your Setup\u003c\/p\u003e\n\u003cp\u003eAssemble as vertical or horizontal\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"Environmental sensors for a clean air workspace\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_Precise_Particle_Sensing.svg?v=1697552028\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eParticle Sensors\u003c\/p\u003e\n\u003cp\u003eContinuous air quality management\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6 col-sm-4 col-md-3 text-center margin-top\"\u003e\n\u003cimg alt=\"UV light in the vertical laminar flow hood\" height=\"50\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Icon_LED.svg?v=1697547259\" width=\"50\"\u003e\n\u003cp class=\"blue-heading no-margin text-center\"\u003eUV Lighting\u003c\/p\u003e\n\u003cp\u003eGuarantee a clean work surface\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cfigure\u003e\u003cvideo class=\"widescreen\" controls=\"controls\" controlslist=\"nodownload\" crossorigin=\"\" height=\"477.172\" poster=\"https:\/\/cdn.ossila.com\/videos\/laminar-flow-hood-product-overview.jpg\" preload=\"none\" title=\"Laminar Flow HoodProduct Overview\" width=\"848.328\"\u003e\n\u003csource src=\"https:\/\/cdn.ossila.com\/videos\/laminar-flow-hood-product-overview.mp4\" type=\"video\/mp4\"\u003e\n\u003ctrack default=\"\" kind=\"subtitles\" label=\"English\" src=\"https:\/\/cdn.ossila.com\/videos\/laminar-flow-hood-product-overview.vtt\" srclang=\"en\"\u003e\u003c\/video\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n\"@context\": \"https:\/\/schema.org\",\n\"@type\": \"VideoObject\",\n\"name\": \"Laminar Flow Hood Product Overview\",\n\"description\": \"Ossila Laminar Flow Hood Product Overview\",\n\"thumbnailUrl\": \"https:\/\/cdn.ossila.com\/videos\/laminar-flow-hood-product-overview.jpg\",\n\"uploadDate\": \"2025-01-06\",\n\"contentURL\": \"https:\/\/cdn.ossila.com\/videos\/laminar-flow-hood-product-overview.mp4\",\n\"duration\": \"PT0M50S\"\n}\n\u003c\/script\u003e\u003c\/figure\u003e\n\u003ch2 id=\"specification\"\u003eKey Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eMotor\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMotor Type\u003c\/th\u003e\n\u003ctd\u003eSingle speed AC blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eMaximum Flow Rate\u003c\/th\u003e\n\u003ctd\u003e510m\u003csup\u003e3\u003c\/sup\u003e.hour\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eNoise\u003c\/th\u003e\n\u003ctd\u003e75 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHigh Efficiency Particulate Air Filter\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFilter Grade\u003c\/th\u003e\n\u003ctd\u003e99.99% (H13) particle filtration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePore Size\u003c\/th\u003e\n\u003ctd\u003e0.3 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eISO Classification\u003c\/th\u003e\n\u003ctd\u003eISO Class 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eParticle Sensor\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSensor Type\u003c\/th\u003e\n\u003ctd\u003eLight scattering discrete airborne particulate counter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCount Range\u003c\/th\u003e\n\u003ctd\u003e0 particles.m\u003csup\u003e-3\u003c\/sup\u003e to 100,000 particles.m\u003csup\u003e-3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eCount Accuracy\u003c\/th\u003e\n\u003ctd\u003e±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eParticle Size Bins\u003c\/th\u003e\n\u003ctd\u003e0.3 µm – 1 µm, 1 µm – 2.5 µm, 2.5 µm – 5 µm, 5 µm – 10 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDifferential Pressure Sensor\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eSensor Type\u003c\/th\u003e\n\u003ctd\u003eMEMS barometric pressure sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePressure Range\u003c\/th\u003e\n\u003ctd\u003e30,000 Pa – 120,000 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±6 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eResolution\u003c\/th\u003e\n\u003ctd\u003e±0.2 Pa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eUV Light\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eHigh efficiency UV LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWavelength\u003c\/th\u003e\n\u003ctd\u003e280 nm (UVC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eIntensity\u003c\/th\u003e\n\u003ctd\u003e26 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePower Saving Feature\u003c\/th\u003e\n\u003ctd\u003eAutomatic UV light off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eTimer\u003c\/th\u003e\n\u003ctd\u003e10, 15, 30 minutes, and indefinite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDimensions and Weight\u003c\/h3\u003e\n\u003cfigure class=\"double-float-left\"\u003e\u003cimg alt=\"Vertical Laminar Flow Hood Wireframe\" height=\"512\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Vertical_Laminar_Flow_Hood.jpg?width=512\u0026amp;height=512\" width=\"512\"\u003e\n\u003cfigcaption\u003eVertical configuration\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cfigure class=\"double-float-right\"\u003e\u003cimg alt=\"Horizontal Laminar Flow Hood Wireframe\" height=\"512\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Horizontal_Laminar_Flow_Hood.jpg?v=1651575657\u0026amp;width=512\u0026amp;height=512\" width=\"512\"\u003e\n\u003cfigcaption\u003eHorizontal configuration\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003e\u003c\/th\u003e\n\u003cth\u003eVertical Orientation\u003c\/th\u003e\n\u003cth\u003eHorizontal Orientation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWork Surface\u003c\/th\u003e\n\u003ctd\u003e590 mm x 630 mm (23.2\" x 24.8\")\u003c\/td\u003e\n\u003ctd\u003e590 mm x 630 mm (23.2\" x 24.8\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eInternal Height\u003c\/th\u003e\n\u003ctd\u003e570 mm (22.4\")\u003c\/td\u003e\n\u003ctd\u003e580 mm (22.8\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eExternal Dimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e660 mm x 908 mm x 660 mm\u003cbr\u003e(26\" x 37.8\" x 26\")\u003c\/td\u003e\n\u003ctd\u003e660 mm x 850 mm x 660 mm\u003cbr\u003e(26\" x 33.5\" x 26\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e24 kg\u003c\/td\u003e\n\u003ctd\u003e24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003ca href=\"#specifications-continued\"\u003eView more specifications\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eLaminar Flow Hood Features\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"Horizontal orientation of the Ossila Laminar Flow Hood\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-flow-hood-filter-square.jpg?width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eFully Equipped and Flexible\u003c\/p\u003e\n\u003cp\u003eGet set up straight away with a complete system which includes all the useful components as standard. Plus, the flatpack design means you don't need to decide on a configuration before purchasing. Assemble as a horizontal or vertical laminar flow hood depending on your experimental requirements (or switch between them, if needed).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Laminar Flow Hood filter\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/hepa-filter-close-up-square.jpg?width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eHigh Purity Air\u003c\/p\u003e\n\u003cp\u003eGuarantee a clean air workspace with a H13 grade HEPA filter which captures over 99.99% of all airborne particulates. High air purity as low as ISO Class 5 is easily achieved and maintained using the smart air sensing technology.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-2\"\u003e\u003cimg alt=\"Laminar Flow Hood sensors\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/laminar-flow-hood-filter-square.jpg?width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eSmart Air Sensing Technology\u003c\/p\u003e\n\u003cp\u003eReceive live updates about the environment and filter saturation from the advanced air quality and pressure sensors. The smart air sensing technology ensures the motor is operating at an optimal speed, alerts you to upcoming filter changes, and warns you if the air flow changes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row pad-half-height\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-2\"\u003e\u003cimg alt=\"Laminar Flow Hood screenshot\" class=\"img-round\" height=\"112\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-laminar-flow-hood-screen-square.jpg?width=112\u0026amp;height=112\" width=\"112\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-10\"\u003e\n\u003cp class=\"blue-heading\"\u003eLow Operating Costs\u003c\/p\u003e\n\u003cp\u003eKeep energy usage to a minimum and reduce your operating costs. The laminar flow hood is equipped with low energy lighting, infrared motion sensors for running in standby mode, a UV LED with variable timer settings, and back pressure sensing to monitor HEPA filter saturation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"gallery\"\u003eLaminar Flow Hood Gallery\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eHorizontal Orientation\u003c\/h3\u003e\n\u003cfigure class=\"double-float-left margin-bottom\"\u003e\u003cimg alt=\"Air flow tests inside and outside a laminar flow hood using Triptic Soy agar plates\" class=\"fill\" height=\"417\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Tryptic-Soy-Agar-Contact-Laminar-Flow-Hood-Comparison.jpg?v=1698395997\u0026amp;width=417\u0026amp;height=417\" width=\"417\"\u003e\u003c\/figure\u003e\n\u003cfigure class=\"double-float-right margin-bottom\"\u003e\u003cimg alt=\"Contact tests inside and outside a laminar flow hood using Sabouraud Dextrose agar plates\" class=\"fill\" height=\"417\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Sabouraud-Dextrose-Agar-Contact-Laminar-Flow-Hood-Comparison.jpg?v=1698395481\u0026amp;width=417\u0026amp;height=417\" width=\"417\"\u003e\u003c\/figure\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow-hood-bio-plates.png?width=1024\" title=\"Horizontal Laminar Flow Hood\"\u003e \u003cimg alt=\"Horizontal Laminar Flow Hood\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow-hood-bio-plates.png?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow-screen.jpg?width=1024\" title=\"Horizontal Laminar Flow Screen\"\u003e \u003cimg alt=\"Horizontal Laminar Flow Screen\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow-screen.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow-hood-filter.jpg?width=1024\" title=\"Horizontal Laminar Flow Hood Filter\"\u003e \u003cimg alt=\"Horizontal Laminar Flow Hood Filter\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow-hood-filter.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow.jpg?width=1024\" title=\"Horizontal Laminar Flow\"\u003e \u003cimg alt=\"Horizontal Laminar Flow\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-laminar-flow.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-flow-hood-experiment.jpg?width=1024\" title=\"Horizontal Flow Hood experiment\"\u003e \u003cimg alt=\"Horizontal Flow Hood experiment\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/horizontal-flow-hood-experiment.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca class=\"carousel-left-control\" role=\"button\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-left\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious\u003c\/span\u003e \u003c\/a\u003e \u003ca class=\"carousel-right-control\" role=\"button\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-right\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVertical Orientation\u003c\/h3\u003e\n\u003cfigure\u003e\u003cvideo alt=\"Vertical Laminar Flow Hood Smoke air flow\" autoplay=\"autoplay\" class=\"widescreen\" height=\"477.17\" loop=\"loop\" muted=\"muted\" src=\"https:\/\/cdn.ossila.com\/videos\/Laminar-flow-hood-smoke-flow-1080p.mp4\" title=\"Vertical Laminar Flow Hood Smoke air flow\" type=\"video\/mp4\" width=\"848.33\"\u003e\u003c\/video\u003e\u003c\/figure\u003e\n\u003cdiv class=\"carousel-container carousel-gallery\"\u003e\n\u003cdiv class=\"carousel-track ease-in-out-transition\"\u003e\n\u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/laminar-flow-hood-thin-films-2.jpg?width=1620\" title=\"Thin films made inside and outside a laminar flow hood\"\u003e \u003cimg alt=\"Thin films made inside and outside a laminar flow hood\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/laminar-flow-hood-thin-films-2.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-flow-hood-filter.jpg?width=1620\" title=\"Vertical Flow hood Filter\"\u003e \u003cimg alt=\"Vertical Flow hood Filter\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-flow-hood-filter.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-flow-hood.jpg?width=1620\" title=\"Vertical Flow hood\"\u003e \u003cimg alt=\"Vertical Flow hood\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-flow-hood.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-laminar-flow-hood-screen.jpg?width=1620\" title=\"Vertical Laminar Flow Hood Screen\"\u003e \u003cimg alt=\"Vertical Laminar Flow Hood Screen\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-laminar-flow-hood-screen.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-laminar-flow-hood-top-corner.jpg?width=1620\" title=\"Vertical Laminar Flow Hood\"\u003e \u003cimg alt=\"Vertical Laminar Flow Hood\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-laminar-flow-hood-top-corner.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e \u003ca class=\"carousel-item\" href=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-flow-hood-lights.jpg?width=1620\" title=\"Vertical Laminar Flow Hood lights\"\u003e \u003cimg alt=\"Vertical Laminar Flow Hood lights\" height=\"280\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/vertical-flow-hood-lights.jpg?width=420\u0026amp;height=280\u0026amp;crop=center\" width=\"420\"\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ca class=\"carousel-left-control\" role=\"button\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-left\"\u003e\u003cuse href=\"#icon-chevron-left\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003ePrevious\u003c\/span\u003e \u003c\/a\u003e \u003ca class=\"carousel-right-control\" role=\"button\"\u003e \u003csvg aria-hidden=\"true\" class=\"icon icon-chevron-right\"\u003e\u003cuse href=\"#icon-chevron-right\"\u003e\u003c\/use\u003e\u003c\/svg\u003e \u003cspan class=\"sr-only\"\u003eNext\u003c\/span\u003e \u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"specifications-continued\"\u003eAdditional Specifications\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch3\u003eWoven Microfiber Pre-Filter\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFilter Grade\u003c\/th\u003e\n\u003ctd\u003e60% (F5) particle filtration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhite Light\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eHigh efficiency LED array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eBrightness\u003c\/th\u003e\n\u003ctd\u003e850 Lumens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDisplay Type\u003c\/th\u003e\n\u003ctd\u003e24 bit color TFT LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDisplay Resolution\u003c\/th\u003e\n\u003ctd\u003e480 x 272 px\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eDisplay Size\u003c\/th\u003e\n\u003ctd\u003e4.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eInterface\u003c\/th\u003e\n\u003ctd\u003eTactile keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eIEC C13 power cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eVoltage Range\u003c\/th\u003e\n\u003ctd\u003e220 V – 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eFuse\u003c\/th\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"text-muted\"\u003ePlease note: Countries with 110V mains will require a step up transformer rated for powers up to at least 250W to operate the equipment.\u003c\/p\u003e\n\u003ch3\u003eMaterials and Finish\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003ePlenum and Back Panels\u003c\/th\u003e\n\u003ctd\u003e1.5 mm Aluminum, textured black powder coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eClear Side Panels and Sash\u003c\/th\u003e\n\u003ctd\u003e5 mm acrylic, transparent with polished edges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eWorking Surface Tray\u003c\/th\u003e\n\u003ctd\u003e1.5 mm stainless steel, #4 brushed finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCertification and Standards\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eUK Conformity Assessment (UKCA)\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eLow Voltage Electrical Equipment\u003c\/p\u003e\n\u003cp\u003eElectromagnetic Compatibility\u003c\/p\u003e\n\u003cp\u003eRestriction of Hazardous Substances\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eConformitè Europëenne (CE) Mark\u003c\/th\u003e\n\u003ctd\u003e\n\u003cp\u003eLow Voltage Directive (2014\/35\/EU)\u003c\/p\u003e\n\u003cp\u003eElectromagnetic Compatibility (EMC) (2014\/30\/EU)\u003c\/p\u003e\n\u003cp\u003eRestriction of Hazardous Substances (RoHS) (2011\/65\/EU + 2015\/863)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth width=\"38.2%\"\u003eInternational Standards\u003c\/th\u003e\n\u003ctd\u003eBS EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use. General requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"included\"\u003eIn the Box\u003c\/h2\u003e\n\u003chr\u003e\n\u003cul\u003e\n\u003cli\u003eFlat-pack laminar flow hood (configurable in vertical or horizontal setup)\u003c\/li\u003e\n\u003cli\u003eHEPA filter\u003c\/li\u003e\n\u003cli\u003ePre-filter\u003c\/li\u003e\n\u003cli\u003eStainless steel tray\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"accessories\"\u003eAccessories and Related Products\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e[[collection handle=\"equipment-accessories\" tags=\"laminar flow hood\"]]\u003c\/p\u003e\n\u003ch2 id=\"resources\"\u003eResources and Support\u003c\/h2\u003e\n\u003chr\u003e\n\u003cdiv class=\"tile-container\"\u003e\n\u003cdiv class=\"card-box card-truncate\"\u003e\n\u003ca href=\"\/pages\/getting-started-laminar-flow-hood\"\u003e\u003cimg alt=\"Ossila Laminar Flow Hood control panel\" height=\"160\" loading=\"lazy\" src=\"https:\/\/www.ossila.com\/cdn\/shop\/files\/Laminar-flow-hood-interface.png?width=160\u0026amp;height=160\u0026amp;crop=center\"\u003e\u003c\/a\u003e\u003ca href=\"\/pages\/getting-started-laminar-flow-hood\"\u003eGetting Started with the Laminar Flow Hood\u003c\/a\u003e\n\u003cp\u003eThis short video guide shows you how to get started with your new equipment. It is easy to control the fan, lighting, and internal UV light.\u003c\/p\u003e\n\u003ca href=\"\/pages\/getting-started-laminar-flow-hood\"\u003eRead more...\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Ossila","offers":[{"title":"Type B (US)","offer_id":49906647498968,"sku":"L2008A1-US","price":2250.0,"currency_code":"GBP","in_stock":true},{"title":"Type F (EU)","offer_id":49906647531736,"sku":"L2008A1-EU","price":2250.0,"currency_code":"GBP","in_stock":true},{"title":"Type G (UK)","offer_id":49906647564504,"sku":"L2008A1-UK","price":2250.0,"currency_code":"GBP","in_stock":true},{"title":"Type I (AU)","offer_id":49906647597272,"sku":"L2008A1-AU","price":2250.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/files\/Horizontal-Laminar-Flow-Hood.png?v=1768828099"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0287\/collections\/life-sciences-collection-featured-photo_2d6a7242-2689-40fc-8195-114524036258.jpg?v=1786355944","url":"https:\/\/www.ossila.com\/collections\/cleanroom-equipment.oembed","provider":"Ossila","version":"1.0","type":"link"}